报价 (0)

HIMA F6202 981620202 Safety Related Controller Module

产品介绍 The HIMA F6202 (981620202) Safety Related Controller Module is an integral logic processing component within HIMAs renowned HIQuad safety system architecture . Engineered for high

零件号: 2857 有库存
HIMA F6202 981620202 Safety Related Controller Module

产品规格

发布时间Jul 07, 2026
制造商 黑马
型号 F6202 981620202
零件号 IN2857
状态100% 全新
发货港口中国厦门
交货时间1-3 个工作日
证书COO
快递合作伙伴DHL, UPS, TNT, FedEx and EMS.
保修 1 年
单价
$1,369.00
USD / 单位
-
+
最小起订量: 1 件
0.0


运输信息
订单满额免运费 $5,000
美国东部时间下午 3 点前下单,当日发货
提供国际运输
HIMA F6202 981620202 Safety Related Controller Module HIMA F6202 981620202 Safety Related Controller Module HIMA F6202 981620202 Safety Related Controller Module HIMA F6202 981620202 Safety Related Controller Module

产品介绍

The HIMA F6202 (981620202) Safety Related Controller Module is an integral logic processing component within HIMA’s renowned HIQuad safety system architecture. Engineered for high-integrity industrial automation and safety-critical applications, the F6202 is designed to handle safety instrumented functions (SIFs) with the highest level / dependability and compliance. It supports SIL 3 certification under IEC 61508, ensuring optimal reliability in environments where human safety and asset protection are non-negotiable.

Manufactured by HIMA Paul Hildebrandt GmbH, a global leader in industrial safety automation, the F6202 module functions as a central processor 件 (CPU) in systems requiring fast and deterministic responses to process hazards. It is particularly suited to industries such as chemical processing, power generation, oil & gas, and pharmaceuticals, where continuous safety monitoring and controlled emergency shutdowns are essential.

With built-in diagnostics, real-time processing, and seamless integration capabilities, the F6202 contributes to minimizing downtime, maximizing productivity, and ensuring system-wide compliance.


产品规格

Parameter Specification
型号 F6202 (零件号. 981620202)
制造商 HIMA Paul Hildebrandt GmbH
Function Safety-Related CPU Module
System Compatibility HIMA HIQuad System
SIL Certification SIL 3 (IEC 61508 compliant)
Application Role Central controller for safety logic execution
Logic Processing Capability Deterministic, cyclic execution
Communication Interface HIMA proprietary system bus
Diagnostic Functions Continuous self-monitoring, fault detection
Programming Tools ELOP II Factory
Power Supply 24 V DC nominal (Redundant PSU possible)
Operating Temperature 0°C to +60°C
Storage Temperature -40°C to +85°C
Humidity Resistance 5% to 95%, non-condensing
Mounting Rack mount (HIQuad system frame)
EMC/Imm件y IEC 61000-6-2 / 61000-6-4
Shock/Vibration IEC 60068-2-6 / 60068-2-27 compliant
Dimensions (H x W x D) 216 x 130 x 30 mm
重量 0.2 kg

Product Applications

The F6202 module is purpose-built for integration into Safety Instrumented Systems (SIS). Its primary applications include:

  • Emergency Shutdown Systems (ESD) – Ensures safe plant shutdown in response to critical process conditions.

  • Fire & Gas Detection Systems (F&G) – Real-time response to fire and gas detection sensors.

  • High-Integrity Pressure Protection Systems (HIPPS) – Protects pipelines and pressure vessels from overpressure.

  • Turbomachinery Protection – Handles real-time control logic for critical rotating machinery.

  • Boiler and Burner Management Systems (BMS) – Manages flame detection and burner sequencing safely.

  • Critical Process Automation – In pharmaceuticals, refineries, and petrochemical installations where safety cannot be compromised.

Each application benefits from the F6202’s rapid decision-making and its built-in diagnostics, enabling operators to act confidently in safety-critical scenarios.


Product Advantages

  • SIL 3 Certified Safety Performance
    Compliant with IEC 61508 for use in demanding safety applications.

  • Reliable System Redundancy 支持
    Can be configured in redundant system topologies to eliminate single points / failure.

  • Compact, Modular Design
    Enables efficient use / rack space in HIQuad systems while allowing for future scalability.

  • Real-Time Diagnostics
    Monitors internal performance and external communication continuously to detect faults early.

  • High Processing Speed
    Executes control logic cycles with deterministic timing for immediate hazard response.

  • Reduced Maintenance Overhead
    Long lifecycle, low power consumption, and minimal maintenance requirements.

  • Field-Proven Architecture
    Widely used in legacy and modern HIMA safety system deployments globally.


常见问题 (FAQ)

  1. What is the primary function / the HIMA F6202 module?
    It serves as a logic processing CPU in HIMA HIQuad safety systems for executing safety instrumented functions.

  2. What safety certification does the F6202 meet?
    The module is certified for SIL 3 compliance under the IEC 61508 safety standard.

  3. Can the F6202 operate in a redundant setup?
    Yes, it fully supports redundant configurations to ensure system availability and eliminate downtime.

  4. What s/tware is used for programming the F6202?
    The module is configured and programmed using HIMA ELOP II Factory s/tware.

  5. How is fault detection handled?
    The module has built-in diagnostic mechanisms for self-monitoring and fault reporting in real-time.

  6. Is the F6202 compatible with third-party PLCs or DCS?
    It communicates via system bus, but additional interface modules (e.g., F7133 for RS485) are required for third-party integration.

  7. What type / mounting does the F6202 require?
    It is designed for rack mounting in HIMA HIQuad enclosures.

  8. What is the expected service life / the F6202 module?
    Over 15 years under standard operating conditions with minimal degradation.

  9. Can I retr/it the F6202 in older HIQuad systems?
    Yes, it’s backward-compatible with most HIQuad setups, making it ideal for upgrades and expansions.

  10. What makes the F6202 different from other controller modules?
    It combines compact size, SIL 3 safety, and real-time performance with seamless integration into HIMA’s proven safety architecture.


Related or Same-Series 型号s

型号 描述 Application Key Feature
F6208 Digital Output Module ESD, Valve Shutdown 8-channel DO, SIL 3
F6217 Analog Input Module Process Monitoring 8-channel AI, fault monitoring
F6220 Digital Input Module Signal Detection, F&G Systems 16-channel DI, fail-safe
F6705 Power Supply Module HIQuad System Powering Redundant 24 VDC input
F6126 System Bus Communication Module Data Communication Backbone HIQuad system interlinking
F8640 CPU Module (Advanced Version) Complex Logic Processing HIMax compatible, high-speed logic

Popular 型号s from the Same 品牌 (HIMA)

型号 描述 Type Feature
F8652X CPU for HIMax High-End Safety Systems Controller Quad-core, high availability
F7130 16-Channel Digital Input Module I/O Module SIL 3, high-speed signal acquisition
F8627X HIMax CPU Controller Module Logic Controller Redundant support, SIL 3
F6706 System Power Supply for HIMax Power Supply Modular, high reliability
F6214 Analog Output Module Output Module 4-channel AO, diagnostics enabled
F7553 Frequency Input Module Signal Processing Module Speed/pulse measurement, SIL 3

公司信息

E-mail: [email protected]

Mobile:请通过邮件联系

Whatsapp:请通过邮件联系

Add: 中国福建省厦门市思明区吕岭路2号阿里山大厦,邮编:361006

我们的服务

我们专业提供工业自动化零部件,并附有一年质保。我们的工业自动化零部件销往全球。

我们能提供来自不同国家和制造商的设备及备件,解决您在多处的顾虑或质量问题,并具有极大的价格优势。

欢迎来电咨询更多产品详情。

产品保修与客户保障

保修详情
  • 2 年标准保修 – 涵盖材料和工艺缺陷
  • 可选延长保修 – 将保修期延长至 5 年
  • 现场技术支持 – 提供经过工厂培训的工程师服务
  • 更换计划 – 48 小时内优先更换
  • 持续的技术协助 – 所有产品的终身支持
质量合规
  • 100% 测试与验证 – 每件产品发货前均经过检查
  • ISO 9001 认证 – 遵守质量管理体系
  • 环境合规 – 符合 RoHS 和 CE 标准
  • 全球安全认证 – UL、cUL 及其他适用认证
  • 可追溯生产 – 完整的序列号和批次可追溯性
退换货政策
  • 30 天退货期 – 未使用产品的退款
  • 无补货费 – 退货处理不收取额外费用
  • 免费退货运费 – 针对有缺陷或错误的商品
  • 交叉发货支持 – 在更换期间最大限度地减少停机时间
  • 简单的 RMA 流程 – 提供在线退货授权
客户权益与支持
  • 价格匹配保证 – 30 天产品价格保护
  • 预留库存 – 为回头客提供优先库存
  • 技术培训 – 提供在线和现场产品培训课程
  • 集成协助 – 为 PLC/DCS 集成提供工程支持
  • 旧型号产品支持 – 为已停产的模块持续提供服务
保修条款与条件
涵盖项目:
  • 材料和工艺方面的制造缺陷
  • 正常使用下的组件故障
  • 固件或软件问题(提供更新)
  • 文档中的错误或遗漏
除外条款:
  • 错误安装或不当使用
  • 未经授权的修改或维修
  • 事故、误用或疏忽造成的损坏
  • 随时间的正常磨损
重要说明:
  • 所有保修或退货请求均需提供购买凭证
  • 退货时应保留原包装
  • 定制配置或特殊订单产品可能有不同的退货条件
  • 国际运输可能需要考虑额外的处理或运输事项

技术文档

Check out HIMA F6202 981620202 Safety Related Controller Module latest technical documentation.

客户评价

发表评论

请通过邮件联系 [email protected] 请通过邮件联系 Follow us on Facebook Subscribe on YouTube