Devis (0)

HIMA F6202 981620202 Safety Related Controller Module

Présentation du produit The HIMA F6202 (981620202) Safety Related Controller Module is an integral logic processing component within HIMAs renowned HIQuad safety system architecture . Engineered for high

Référence: 2857 En stock
HIMA F6202 981620202 Safety Related Controller Module

Spécifications du produit

Date de sortieJul 07, 2026
Fabricant Modules DCS Hima
Modèle F6202 981620202
Référence IN2857
État100 % neuf
Port d'expéditionXiamen, Chine
Délai de livraison1-3 jours ouvrés
CertificatCOO
Partenaires de livraisonDHL, UPS, TNT, FedEx and EMS.
Garantie 1 an
Prix unitéaire
$1,369.00
USD / Unité
-
+
Commande minimum: 1 unité
0.0


Informations de livraison
Livraison gratuite pour les commandes de plus de $5,000
Expédition le jour même pour les commandes passées avant 15h00 HNE.
Expédition internationale disponible
HIMA F6202 981620202 Safety Related Controller Module HIMA F6202 981620202 Safety Related Controller Module HIMA F6202 981620202 Safety Related Controller Module HIMA F6202 981620202 Safety Related Controller Module

Présentation du produit

The HIMA F6202 (981620202) Safety Related Controller Module is an integral logic processing component within HIMA’s renowned HIQuad safety system architecture. Engineered for high-integrity industrial automation and safety-critical applications, the F6202 is designed to handle safety instrumented functions (SIFs) with the highest level sur dependability and compliance. It supports SIL 3 certification under IEC 61508, ensuring optimal reliability in environments where human safety and asset protection are non-negotiable.

Manufactured by HIMA Paul Hildebrandt GmbH, a global leader in industrial safety automation, the F6202 module functions as a central processor unité (CPU) in systems requiring fast and deterministic responses to process hazards. It is particularly suited to industries such as chemical processing, power generation, oil & gas, and pharmaceuticals, where continuous safety monitoring and controlled emergency shutdowns are essential.

With built-in diagnostics, real-time processing, and seamless integration capabilities, the F6202 contributes to minimizing downtime, maximizing productivity, and ensuring system-wide compliance.


Spécifications du produit

Parameter Specification
Modèle F6202 (Référence. 981620202)
Fabricant HIMA Paul Hildebrandt GmbH
Function Safety-Related CPU Module
System Compatibility HIMA HIQuad System
SIL Certification SIL 3 (IEC 61508 compliant)
Application Role Central controller for safety logic execution
Logic Processing Capability Deterministic, cyclic execution
Communication Interface HIMA proprietary system bus
Diagnostic Functions Continuous self-monitoring, fault detection
Programming Tools ELOP II Factory
Power Supply 24 V DC nominal (Redundant PSU possible)
Operating Temperature 0°C to +60°C
Storage Temperature -40°C to +85°C
Humidity Resistance 5% to 95%, non-condensing
Mounting Rack mount (HIQuad system frame)
EMC/Immunitéy IEC 61000-6-2 / 61000-6-4
Shock/Vibration IEC 60068-2-6 / 60068-2-27 compliant
Dimensions (H x W x D) 216 x 130 x 30 mm
Poids 0.2 kg

Product Applications

The F6202 module is purpose-built for integration into Safety Instrumented Systems (SIS). Its primary applications include:

  • Emergency Shutdown Systems (ESD) – Ensures safe plant shutdown in response to critical process conditions.

  • Fire & Gas Detection Systems (F&G) – Real-time response to fire and gas detection sensors.

  • High-Integrity Pressure Protection Systems (HIPPS) – Protects pipelines and pressure vessels from overpressure.

  • Turbomachinery Protection – Handles real-time control logic for critical rotating machinery.

  • Boiler and Burner Management Systems (BMS) – Manages flame detection and burner sequencing safely.

  • Critical Process Automation – In pharmaceuticals, refineries, and petrochemical installations where safety cannot be compromised.

Each application benefits from the F6202’s rapid decision-making and its built-in diagnostics, enabling operators to act confidently in safety-critical scenarios.


Product Advantages

  • SIL 3 Certified Safety Performance
    Compliant with IEC 61508 for use in demanding safety applications.

  • Reliable System Redundancy Support
    Can be configured in redundant system topologies to eliminate single points sur failure.

  • Compact, Modular Design
    Enables efficient use sur rack space in HIQuad systems while allowing for future scalability.

  • Real-Time Diagnostics
    Monitors internal performance and external communication continuously to detect faults early.

  • High Processing Speed
    Executes control logic cycles with deterministic timing for immediate hazard response.

  • Reduced Maintenance Overhead
    Long lifecycle, low power consumption, and minimal maintenance requirements.

  • Field-Proven Architecture
    Widely used in legacy and modern HIMA safety system deployments globally.


Questions fréquentes (FAQ)

  1. What is the primary function sur the HIMA F6202 module?
    It serves as a logic processing CPU in HIMA HIQuad safety systems for executing safety instrumented functions.

  2. What safety certification does the F6202 meet?
    The module is certified for SIL 3 compliance under the IEC 61508 safety standard.

  3. Can the F6202 operate in a redundant setup?
    Yes, it fully supports redundant configurations to ensure system availability and eliminate downtime.

  4. What ssurtware is used for programming the F6202?
    The module is configured and programmed using HIMA ELOP II Factory ssurtware.

  5. How is fault detection handled?
    The module has built-in diagnostic mechanisms for self-monitoring and fault reporting in real-time.

  6. Is the F6202 compatible with third-party PLCs or DCS?
    It communicates via system bus, but additional interface modules (e.g., F7133 for RS485) are required for third-party integration.

  7. What type sur mounting does the F6202 require?
    It is designed for rack mounting in HIMA HIQuad enclosures.

  8. What is the expected service life sur the F6202 module?
    Over 15 years under standard operating conditions with minimal degradation.

  9. Can I retrsurit the F6202 in older HIQuad systems?
    Yes, it’s backward-compatible with most HIQuad setups, making it ideal for upgrades and expansions.

  10. What makes the F6202 different from other controller modules?
    It combines compact size, SIL 3 safety, and real-time performance with seamless integration into HIMA’s proven safety architecture.


Related or Same-Series Modèles

Modèle Description Application Key Feature
F6208 Digital Output Module ESD, Valve Shutdown 8-channel DO, SIL 3
F6217 Analog Input Module Process Monitoring 8-channel AI, fault monitoring
F6220 Digital Input Module Signal Detection, F&G Systems 16-channel DI, fail-safe
F6705 Power Supply Module HIQuad System Powering Redundant 24 VDC input
F6126 System Bus Communication Module Data Communication Backbone HIQuad system interlinking
F8640 CPU Module (Advanced Version) Complex Logic Processing HIMax compatible, high-speed logic

Popular Modèles from the Same Marque (HIMA)

Modèle Description Type Feature
F8652X CPU for HIMax High-End Safety Systems Controller Quad-core, high availability
F7130 16-Channel Digital Input Module I/O Module SIL 3, high-speed signal acquisition
F8627X HIMax CPU Controller Module Logic Controller Redundant support, SIL 3
F6706 System Power Supply for HIMax Power Supply Modular, high reliability
F6214 Analog Output Module Output Module 4-channel AO, diagnostics enabled
F7553 Frequency Input Module Signal Processing Module Speed/pulse measurement, SIL 3

Informations sur l'entreprise

E-mail: [email protected]

Mobile:Contactez-nous par email

Whatsapp:Contactez-nous par email

Add: Alishan Building, 2 Lvling Rd, District Siming, Xiamen, Fujian, Chine, 361006

Nos services

Nous sommes spécialisés dans la fourniture de pièces d'automatisation industrielle avec une garantie d'un an. Nos pièces d'automatisation industrielle sont vendues dans le monde entier.

Nous pouvons fournir des équipements et des pièces détachées de différents pays et fabricants, résoudre vos inquiétudes ou problèmes de qualité en de nombreux endroits, et surfrir un excellent avantage de prix.

N'hésitez pas à nous appeler pour plus de détails sur les produits.

Garantie produit et assurance client

Détails de la garantie
  • Garantie standard de 2 ans – Couvre les défauts de matériaux et de fabrication
  • Extension de garantie optionnelle – Prolongez la garantie jusqu'à 5 ans
  • Support technique sur site – Ingénieurs formés en usine disponibles
  • Programme de remplacement – Remplacement prioritaire sous 48 heures
  • Assistance technique continue – Support à vie pour tous les produits
Conformité qualité
  • 100 % testé et vérifié – Chaque unitéé inspectée avant expédition
  • Certifié ISO 9001 – Respect du système de gestion de la qualité
  • Conformité environnementale – Normes RoHS et CE respectées
  • Certifications de sécurité mondiales – UL, cUL et autres certifications applicables
  • Production traçable – Traçabilité complète des numéros de série et lots
Politique de retour et d'échange
  • Délai de retour de 30 jours – Remboursement pour les produits non utilisés
  • Pas de frais de réapprovisionnement – Retours traités sans frais supplémentaires
  • Retour gratuit – Pour les articles défectueux ou erronés
  • Support d'échange croisé – Minimisez les temps d'arrêt pendant le remplacement
  • Processus RMA simplifié – Autorisation de retour en ligne disponible
Droits et support client
  • Garantie du meilleur prix – Protection des prix pendant 30 jours
  • Stock réservé – Stock prioritaire pour les clients fidèles
  • Formation technique – Sessions de formation en ligne et sur site disponibles
  • Assistance à l'intégration – Support technique pour l'intégration PLC/DCS
  • Support pour produits anciens – Service continu pour les modules discontinués
États de garantie
Articles couverts:
  • Défauts de fabrication des matériaux et de la main-d'œuvre
  • Défaillances de composants en usage normal
  • Problèmes de firmware ou logiciel (mises à jour fournies)
  • Erreurs ou omissions dans la documentation
Exclusions:
  • Installation incorrecte ou utilisation inappropriée
  • Modifications ou réparations non autorisées
  • Dommages dus à des accidents, une mauvaise utilisation ou une négligence
  • Usure normale au fil du temps
Remarques importantes:
  • Toute demande de garantie ou de retour nécessite une preuve d'achat
  • L'emballage d'origine doit être conservé pour les retours
  • Les produits configurés sur mesure ou commandes spéciales peuvent avoir des conditions de retour différentes
  • Les expéditions internationales peuvent nécessiter des considérations supplémentaires

Documentation technique

Check out HIMA F6202 981620202 Safety Related Controller Module latest technical documentation.

Avis clients

Laisser un avis

Contactez-nous par email [email protected] Contactez-nous par email Follow us on Facebook Subscribe on YouTube