見積もり (0)

HIMA F6202 981620202 Safety Related Controller Module

製品紹介 The HIMA F6202 (981620202) Safety Related Controller Module is an integral logic processing component within HIMAs renowned HIQuad safety system architecture . Engineered for high

品番: 2857 在庫あり
HIMA F6202 981620202 Safety Related Controller Module

製品仕様

発売時期Jul 07, 2026
メーカー Hima DCSモジュール
モデル F6202 981620202
型番 IN2857
状態100%新品
出荷港中国廈門
リードタイム1-3営業日
認証COO
配送パートナーDHL, UPS, TNT, FedEx and EMS.
保証 1年間
単価
$1,369.00
USD / ユニット
-
+
最小注文: 1 台
0.0


配送情報
一定金額以上のご注文で送料無料 $5,000
東部標準時午後3時までのご注文は当日発送いたします。
国際配送可能
HIMA F6202 981620202 Safety Related Controller Module HIMA F6202 981620202 Safety Related Controller Module HIMA F6202 981620202 Safety Related Controller Module HIMA F6202 981620202 Safety Related Controller Module

製品紹介

The HIMA F6202 (981620202) Safety Related Controller Module is an integral logic processing component within HIMA’s renowned HIQuad safety system architecture. Engineered for high-integrity industrial automation and safety-critical applications, the F6202 is designed to handle safety instrumented functions (SIFs) with the highest level / dependability and compliance. It supports SIL 3 certification under IEC 61508, ensuring optimal reliability in environments where human safety and asset protection are non-negotiable.

Manufactured by HIMA Paul Hildebrandt GmbH, a global leader in industrial safety automation, the F6202 module functions as a central processor 台 (CPU) in systems requiring fast and deterministic responses to process hazards. It is particularly suited to industries such as chemical processing, power generation, oil & gas, and pharmaceuticals, where continuous safety monitoring and controlled emergency shutdowns are essential.

With built-in diagnostics, real-time processing, and seamless integration capabilities, the F6202 contributes to minimizing downtime, maximizing productivity, and ensuring system-wide compliance.


製品仕様

Parameter Specification
モデル F6202 (品番. 981620202)
メーカー HIMA Paul Hildebrandt GmbH
Function Safety-Related CPU Module
System Compatibility HIMA HIQuad System
SIL Certification SIL 3 (IEC 61508 compliant)
Application Role Central controller for safety logic execution
Logic Processing Capability Deterministic, cyclic execution
Communication Interface HIMA proprietary system bus
Diagnostic Functions Continuous self-monitoring, fault detection
Programming Tools ELOP II Factory
Power Supply 24 V DC nominal (Redundant PSU possible)
Operating Temperature 0°C to +60°C
Storage Temperature -40°C to +85°C
Humidity Resistance 5% to 95%, non-condensing
Mounting Rack mount (HIQuad system frame)
EMC/Imm台y IEC 61000-6-2 / 61000-6-4
Shock/Vibration IEC 60068-2-6 / 60068-2-27 compliant
Dimensions (H x W x D) 216 x 130 x 30 mm
重量 0.2 kg

Product Applications

The F6202 module is purpose-built for integration into Safety Instrumented Systems (SIS). Its primary applications include:

  • Emergency Shutdown Systems (ESD) – Ensures safe plant shutdown in response to critical process conditions.

  • Fire & Gas Detection Systems (F&G) – Real-time response to fire and gas detection sensors.

  • High-Integrity Pressure Protection Systems (HIPPS) – Protects pipelines and pressure vessels from overpressure.

  • Turbomachinery Protection – Handles real-time control logic for critical rotating machinery.

  • Boiler and Burner Management Systems (BMS) – Manages flame detection and burner sequencing safely.

  • Critical Process Automation – In pharmaceuticals, refineries, and petrochemical installations where safety cannot be compromised.

Each application benefits from the F6202’s rapid decision-making and its built-in diagnostics, enabling operators to act confidently in safety-critical scenarios.


Product Advantages

  • SIL 3 Certified Safety Performance
    Compliant with IEC 61508 for use in demanding safety applications.

  • Reliable System Redundancy サポート
    Can be configured in redundant system topologies to eliminate single points / failure.

  • Compact, Modular Design
    Enables efficient use / rack space in HIQuad systems while allowing for future scalability.

  • Real-Time Diagnostics
    Monitors internal performance and external communication continuously to detect faults early.

  • High Processing Speed
    Executes control logic cycles with deterministic timing for immediate hazard response.

  • Reduced Maintenance Overhead
    Long lifecycle, low power consumption, and minimal maintenance requirements.

  • Field-Proven Architecture
    Widely used in legacy and modern HIMA safety system deployments globally.


よくある質問 (FAQ)

  1. What is the primary function / the HIMA F6202 module?
    It serves as a logic processing CPU in HIMA HIQuad safety systems for executing safety instrumented functions.

  2. What safety certification does the F6202 meet?
    The module is certified for SIL 3 compliance under the IEC 61508 safety standard.

  3. Can the F6202 operate in a redundant setup?
    Yes, it fully supports redundant configurations to ensure system availability and eliminate downtime.

  4. What s/tware is used for programming the F6202?
    The module is configured and programmed using HIMA ELOP II Factory s/tware.

  5. How is fault detection handled?
    The module has built-in diagnostic mechanisms for self-monitoring and fault reporting in real-time.

  6. Is the F6202 compatible with third-party PLCs or DCS?
    It communicates via system bus, but additional interface modules (e.g., F7133 for RS485) are required for third-party integration.

  7. What type / mounting does the F6202 require?
    It is designed for rack mounting in HIMA HIQuad enclosures.

  8. What is the expected service life / the F6202 module?
    Over 15 years under standard operating conditions with minimal degradation.

  9. Can I retr/it the F6202 in older HIQuad systems?
    Yes, it’s backward-compatible with most HIQuad setups, making it ideal for upgrades and expansions.

  10. What makes the F6202 different from other controller modules?
    It combines compact size, SIL 3 safety, and real-time performance with seamless integration into HIMA’s proven safety architecture.


Related or Same-Series モデルs

モデル 説明 Application Key Feature
F6208 Digital Output Module ESD, Valve Shutdown 8-channel DO, SIL 3
F6217 Analog Input Module Process Monitoring 8-channel AI, fault monitoring
F6220 Digital Input Module Signal Detection, F&G Systems 16-channel DI, fail-safe
F6705 Power Supply Module HIQuad System Powering Redundant 24 VDC input
F6126 System Bus Communication Module Data Communication Backbone HIQuad system interlinking
F8640 CPU Module (Advanced Version) Complex Logic Processing HIMax compatible, high-speed logic

Popular モデルs from the Same ブランド (HIMA)

モデル 説明 Type Feature
F8652X CPU for HIMax High-End Safety Systems Controller Quad-core, high availability
F7130 16-Channel Digital Input Module I/O Module SIL 3, high-speed signal acquisition
F8627X HIMax CPU Controller Module Logic Controller Redundant support, SIL 3
F6706 System Power Supply for HIMax Power Supply Modular, high reliability
F6214 Analog Output Module Output Module 4-channel AO, diagnostics enabled
F7553 Frequency Input Module Signal Processing Module Speed/pulse measurement, SIL 3

会社情報

E-mail: [email protected]

Mobile:メールでのお問い合わせ

Whatsapp:メールでのお問い合わせ

Add: 中国福建省廈門市思明区呂嶺路2号 阿里山ビル 〒361006

サービス内容

当社は産業用オートメーション部品の供給を専門としており、1年間の保証を提供しております。当社の産業用オートメーション部品は世界中に販売されています。

当社は様々な国やメーカーの機器及びスペアパーツを提供し、複数拠点でのご不安や品質問題を解消するとともに、大きな価格メリットを実現しております。

製品詳細については、お気軽にお電話にてお問い合わせください。

製品保証とお客様サポート

保証詳細
  • 2年間標準保証 – 材料および製造上の欠陥をカバー
  • オプション延長保証 – 最大5年まで延長可能
  • オンサイト技術サポート – 工場トレーニングを受けたエンジニアが対応
  • 交換プログラム – 48時間以内の優先交換
  • 継続的技術支援 – 全製品のライフタイムサポート
品質コンプライアンス
  • 100%テスト済み・検証済み – 出荷前に各ユニットを検査
  • ISO 9001認証取得 – 品質マネジメントシステム準拠
  • 環境コンプライアンス – RoHSおよびCE基準準拠
  • 国際安全認証 – UL、cUL、その他該当する認証
  • トレーサブル生産 – 完全なシリアルおよびバッチ追跡
返品・交換ポリシー
  • 30日間返品期間 – 未使用製品の返金
  • 再入庫手数料なし – 追加料金なしで返品処理
  • 返品送料無料 – 不良品または誤品の場合
  • 交換品先行発送 – 交換中のダウンタイムを最小化
  • 簡単RMA手続き – オンライン返品承認が可能
お客様の権利とサポート
  • プライスマッチ保証 – 30日間の製品価格保護
  • 優先在庫確保 – リピーター様向け優先在庫
  • 技術トレーニング – オンラインおよびオンサイトでの製品トレーニング
  • 統合支援 – PLC/DCS統合のエンジニアリングサポート
  • レガシー製品サポート – 製造中止モジュールの継続サービス
保証規約
保証対象:
  • 材料および製造上の欠陥
  • 通常使用下での部品故障
  • ファームウェアまたはソフトウェアの問題(アップデート提供)
  • ドキュメントの誤りまたは欠落
保証除外事項:
  • 誤った設置または不適切な使用
  • 無許可の改造または修理
  • 事故、誤用、または不注意による損傷
  • 経年による通常の摩耗
重要事項:
  • すべての保証または返品リクエストには購入証明が必要です
  • 返品の際は元の梱包材を保管してください
  • カスタム設定品または特注品は異なる返品条件が適用される場合があります
  • 国際配送には追加の手続きや配送条件が適用される場合があります

技術文書

Check out HIMA F6202 981620202 Safety Related Controller Module latest technical documentation.

お客様のレビュー

レビューを投稿

メールでのお問い合わせ [email protected] メールでのお問い合わせ Follow us on Facebook Subscribe on YouTube