报价 (0)

Yokogawa KS1-10*B Signal Cable

产品介绍 The Yokogawa KS1-10*B Signal Cable is a high-quality, shielded signal transmission cable developed specifically for integration with Yokogawas process automation systems. This mod

零件号: 1893
TAGS:
有库存
Yokogawa KS1-10*B Signal Cable

产品规格

发布时间Jul 07, 2026
制造商 横河
型号 KS1-10*B
零件号 IN1893
状态100% 全新
发货港口中国厦门
交货时间1-3 个工作日
证书COO
快递合作伙伴DHL, UPS, TNT, FedEx and EMS.
保修 1 年
单价
$2,009.00
USD / 单位
-
+
最小起订量: 1 件
0.0


运输信息
订单满额免运费 $5,000
美国东部时间下午 3 点前下单,当日发货
提供国际运输
Yokogawa KS1-10*B Signal Cable Yokogawa KS1-10*B Signal Cable Yokogawa KS1-10*B Signal Cable Yokogawa KS1-10*B Signal Cable

产品介绍

The Yokogawa KS1-10*B Signal Cable is a high-quality, shielded signal transmission cable developed specifically for integration with Yokogawa’s process automation systems. This model is part / the KS1 series, known for its reliable signal integrity, flexible construction, and resistance to electromagnetic interference (EMI).

With 10 individually insulated conductors, the KS1-10*B is designed for transmitting analog and digital control signals in Distributed Control Systems (DCS), field instruments, and various process control environments. It is particularly well-suited for use in plants where equipment is distributed across long distances, and consistent, noise-free signal transmission is required.

The outer jacket and inner insulation materials ensure robust performance in industrial environments with elevated electrical noise and potential mechanical stress.


产品规格

Parameter Specification
型号 KS1-10*B
Cable Type Multicore Shielded Signal Cable
Number / Cores 10 conductors
Conductor Type Stranded tinned copper
Conductor Size 0.5 mm²
Insulation Material Heat-resistant PVC
Outer Jacket Material Flame-retardant PVC
Shielding Aluminium foil with drain wire
Voltage Rating 300V (AC/DC)
Temperature Range -15°C to +70°C
Cable Diameter 7.8 mm
Bend Radius (Minimum) 5 x OD (~39 mm)
Cable Length up to 10 meters
Package 重量 2 kg
Color Coding Standard industrial color code
Flame Rating IEC 60332-1 flame retardant
Compliance RoHS, CE, REACH compliant
Connector Type Open-ended, suitable for termination customization

Product Applications

The KS1-10*B cable is engineered for use in a wide variety / industrial automation and control system applications where reliable low-voltage signal transmission is essential:

  • Yokogawa CENTUM VP and ProSafe-RS DCS systems

  • Connection / field instrumentation (e.g., transmitters, analyzers)

  • Signal loops in chemical, oil & gas, and power generation industries

  • Remote I/O module wiring

  • Sensor/actuator interface cabling

  • Instrumentation panels and marshalling cabinets

  • OEM control panel manufacturing

  • Redundant safety system signal routing


Product Advantages

  • Optimized for Yokogawa Systems
    Designed in alignment with Yokogawa system architectures, ensuring seamless and interference-free performance in control environments.

  • High Signal Fidelity
    The shielding layer and tinned copper conductors reduce signal degradation over long cable runs, maintaining data accuracy.

  • Installation Flexibility
    Flexible outer jacket and small bend radius allow easy routing in crowded control cabinets or conduits.

  • Industrial-Grade Durability
    PVC insulation and outer sheath provide resistance to oil, moisture, and flame, suitable for harsh environments.

  • Standards Compliant
    Meets international standards for flame retardancy, electrical safety, and environmental compliance (RoHS, CE).

  • Versatile Use
    Suitable for both analog and digital signal wiring across diverse industries, reducing inventory complexity.


常见问题 (FAQ)

1. Is the KS1-10*B cable approved for use in hazardous areas?
While the cable itself is not classified for hazardous zones, it can be used in conjunction with certified junction boxes and barriers in such areas. Always consult project-specific approvals.

2. What makes this cable different from standard commercial signal cables?
KS1-10*B is purpose-built for industrial automation, /fering enhanced EMI shielding, durable jacketing, and compatibility with Yokogawa systems.

3. Can this cable be used for 24V DC control signals?
Yes, it is well-suited for 24V DC signal loops, including digital I/O and low-current relay control circuits.

4. Is the KS1-10*B suitable for outdoor installations?
It is primarily intended for indoor use. For outdoor or UV-exposed applications, additional conduit or protective tubing is recommended.

5. Can I order this cable in custom lengths or with connectors?
Yes. Cable up to 10 meters.

6. How does this cable perform near variable frequency drives (VFDs)?
Its shielding /fers good protection against VFD noise. However, for extreme noise zones, consider double-shielded or VFD-rated cables.

7. What is the maximum conductor resistance?
Typical conductor resistance is less than 39 ohms/km at 20°C, ensuring low voltage drop over typical control distances.

8. Does it support twisted pairs inside?
No, the KS1-10*B has parallel laid conductors, not twisted pairs. For differential signal transmission, twisted-pair models are available.

9. What stripping tools are recommended for this cable?
Standard insulation strippers with adjustable depth settings work well. Avoid tools that may damage inner shielding or conductor strands.

10. Is there a halogen-free version / this cable available?
Currently, KS1-10*B uses standard PVC. For applications requiring low smoke zero halogen (LSZH), alternative variants can be sourced via special order.


Related 型号s from the Same Series or Family

型号 描述 Length Core Count Shielding
KS1-6*B 6-core signal cable for compact installations 10 m 6 Yes
KS1-12*B 12-core signal cable 10 m 12 Yes
KS1-10*B-LS LSZH version for fire-sensitive areas 10 m 10 Yes
KS1-10*BL Black sheath version for dark paneling 10 m 10 Yes
KS1-10*B-XL Extended length variant 20 m 10 Yes
KS2-10*B Heavier duty version with thicker jacket 10 m 10 Yes (enhanced)

Popuar Yokogawa 型号s

型号 分类 描述 Primary Use
EJX530A Pressure Transmitter High-performance DP transmitter Differential pressure measurement
YHC4200 Field Communicator Universal HART communicator Field device configuration
ADMAG AXR Electromagnetic Flowmeter Two-wire loop-powered flowmeter Flow measurement
GX10 Paperless Recorder Compact 10-channel touchscreen recorder Process data recording
UTAdvanced UT35A Temperature Controller High-speed digital controller Thermal control in process systems
FAM3 Remote I/O System Modular and compact I/O station Field signal acquisition and output

公司信息

E-mail: [email protected]

Mobile:请通过邮件联系

Whatsapp:请通过邮件联系

Add: 中国福建省厦门市思明区吕岭路2号阿里山大厦,邮编:361006

我们的服务

我们专业提供工业自动化零部件,并附有一年质保。我们的工业自动化零部件销往全球。

我们能提供来自不同国家和制造商的设备及备件,解决您在多处的顾虑或质量问题,并具有极大的价格优势。

欢迎来电咨询更多产品详情。

产品保修与客户保障

保修详情
  • 2 年标准保修 – 涵盖材料和工艺缺陷
  • 可选延长保修 – 将保修期延长至 5 年
  • 现场技术支持 – 提供经过工厂培训的工程师服务
  • 更换计划 – 48 小时内优先更换
  • 持续的技术协助 – 所有产品的终身支持
质量合规
  • 100% 测试与验证 – 每件产品发货前均经过检查
  • ISO 9001 认证 – 遵守质量管理体系
  • 环境合规 – 符合 RoHS 和 CE 标准
  • 全球安全认证 – UL、cUL 及其他适用认证
  • 可追溯生产 – 完整的序列号和批次可追溯性
退换货政策
  • 30 天退货期 – 未使用产品的退款
  • 无补货费 – 退货处理不收取额外费用
  • 免费退货运费 – 针对有缺陷或错误的商品
  • 交叉发货支持 – 在更换期间最大限度地减少停机时间
  • 简单的 RMA 流程 – 提供在线退货授权
客户权益与支持
  • 价格匹配保证 – 30 天产品价格保护
  • 预留库存 – 为回头客提供优先库存
  • 技术培训 – 提供在线和现场产品培训课程
  • 集成协助 – 为 PLC/DCS 集成提供工程支持
  • 旧型号产品支持 – 为已停产的模块持续提供服务
保修条款与条件
涵盖项目:
  • 材料和工艺方面的制造缺陷
  • 正常使用下的组件故障
  • 固件或软件问题(提供更新)
  • 文档中的错误或遗漏
除外条款:
  • 错误安装或不当使用
  • 未经授权的修改或维修
  • 事故、误用或疏忽造成的损坏
  • 随时间的正常磨损
重要说明:
  • 所有保修或退货请求均需提供购买凭证
  • 退货时应保留原包装
  • 定制配置或特殊订单产品可能有不同的退货条件
  • 国际运输可能需要考虑额外的处理或运输事项

技术文档

Check out Yokogawa KS1-10*B Signal Cable latest technical documentation.

客户评价

发表评论

请通过邮件联系 [email protected] 请通过邮件联系 Follow us on Facebook Subscribe on YouTube