报价 (0)

Yokogawa ADM11-S3 联系我们 Input Module

产品介绍 The Yokogawa ADM11-S3 联系我们 Input Module is a high-performance digital input module designed for use with the CENTUM CS 3000 and CENTUM VP distributed control systems (DCS). Eng

零件号: 2321
TAGS:
有库存
Yokogawa ADM11-S3 联系我们 Input Module

产品规格

发布时间Jul 07, 2026
制造商 横河
型号 ADM11-S3
零件号 IN2321
状态100% 全新
发货港口中国厦门
交货时间1-3 个工作日
证书COO
快递合作伙伴DHL, UPS, TNT, FedEx and EMS.
保修 1 年
单价
$1,279.00
USD / 单位
-
+
最小起订量: 1 件
0.0


运输信息
订单满额免运费 $5,000
美国东部时间下午 3 点前下单,当日发货
提供国际运输
Yokogawa ADM11-S3 联系我们 Input Module Yokogawa ADM11-S3 联系我们 Input Module Yokogawa ADM11-S3 联系我们 Input Module Yokogawa ADM11-S3 联系我们 Input Module

产品介绍

The Yokogawa ADM11-S3 联系我们 Input Module is a high-performance digital input module designed for use with the CENTUM CS 3000 and CENTUM VP distributed control systems (DCS). Engineered for reliability and long-term operation in industrial environments, the ADM11-S3 allows for precise monitoring / contact signal statuses from field devices, ensuring accurate process automation and safety control. It plays a critical role in capturing digital signals from push buttons, limit switches, relays, and other contact-type sensors.

Built on Yokogawa’s longstanding reputation for robust industrial automation components, the ADM11-S3 /fers 16 channels / contact input and is specifically tailored to meet the demanding standards / process control in industries such as power generation, petrochemicals, oil and gas, and water treatment.


产品规格

Parameter Specification
型号 Number ADM11-S3
Product Type 联系我们 Input Module
Input Channels 16 channels (non-isolated from each other, isolated from system)
Input Signal Type Dry contact or wetted contact signal input
ON 状态 Voltage 15 V DC or higher
OFF 状态 Voltage 5 V DC or lower
Input Impedance Approx. 4.7 kΩ
Scan Interval 100 ms or faster
Power Supply Supplied from the system (no external power required for input detection)
Isolation Optical isolation between field and system
联系我们 Type Voltage-free dry contact
Diagnostic Function Built-in self-diagnostics and status indicators
Operating Temperature 0 to 50°C (32 to 122°F)
Storage Temperature -20 to 70°C (-4 to 158°F)
Humidity Range 5% to 95% RH (non-condensing)
Installation Method Mounted on a baseplate within a control cabinet
Dimensions (W × H × D) 125 x 130 x 248 mm
重量 0.14 kg
Certifications CE, CSA, UL, RoHS compliant

Product Applications

The ADM11-S3 module is widely used in process industries that require dependable digital signal acquisition. Key application scenarios include:

  • Power Plants: Monitoring / switch statuses, interlock contacts, and alarm systems.

  • Oil and Gas Facilities: 联系我们 signal acquisition from field instruments and safety systems.

  • Petrochemical Refineries: Logic interlocks and control signal monitoring in hazardous zones.

  • Water Treatment Plants: Monitoring / float switches, pump contactors, and valve positions.

  • Manufacturing Automation: Integrating machine safety switches and manual override signals into the DCS.


Product Advantages

  • High Reliability: Designed for industrial environments with robust construction and optical isolation.

  • Real-Time Monitoring: Fast scan cycle ensures timely and accurate input data delivery to the control system.

  • Built-in Diagnostics: LEDs and self-check functions enhance troubleshooting and reduce downtime.

  • Space-Efficient: Compact size allows for high-density input signal monitoring within small enclosures.

  • Easy Integration: Seamless compatibility with Yokogawa CENTUM systems ensures effortless configuration.

  • Low Maintenance: Stable operation with minimal drift or degradation over time.

  • Standards Compliant: Meets international safety and environmental standards (CE, RoHS, UL).


常见问题 (FAQ)

  1. What type / signals can the ADM11-S3 accept?
    The ADM11-S3 is designed to accept dry or wetted contact input signals, typically from switches, relays, or other voltage-free contact devices.

  2. Is the module isolated from the system?
    Yes, it features optical isolation between the field inputs and the internal system to ensure safety and prevent signal interference.

  3. How many input channels are available on the ADM11-S3?
    It provides 16 input channels for digital contact signal acquisition.

  4. What is the required ON and OFF voltage for the input signal?
    The ON state requires ≥15V DC, while the OFF state must be ≤5V DC.

  5. Can the module be used in high humidity environments?
    Yes, it supports 5% to 95% relative humidity (non-condensing), suitable for most industrial conditions.

  6. What is the main difference between ADM11-S3 and ADM11-S2?
    The ADM11-S3 typically features improved diagnostics and component revisions for higher reliability compared to older models like ADM11-S2.

  7. What kind / diagnostic features are included?
    The module includes LED indicators and internal self-check routines to detect and notify about internal faults.

  8. Does it require external power for inputs?
    No, the power for detecting input signals is provided internally by the system.

  9. Can I hot-swap this module during operation?
    No, it is not designed for hot-swapping. The system should be powered down before replacing the module.

  10. Is this module compatible with CENTUM VP?
    Yes, it is fully compatible with Yokogawa’s CENTUM VP and CS 3000 systems.


Related 型号s from the Same Series

型号 描述 Input Type Channels Dimensions (mm) 重量
ADM11-S2 上一页 version / ADM11-S3 联系我们 Input 16 27.2×130×176 0.2 kg
ADM12-S3 High-speed digital input module 联系我们 Input 16 27.2×130×176 0.2 kg
ADM51 Dual-redundant input module 联系我们 Input 16 27.2×130×176 0.2 kg
ADV151 Mixed input/output module Analog/Digital 8/8 27.2×130×176 0.25 kg
AAI141-S1 Analog input module Analog Input 16 27.2×130×176 0.2 kg
ADV111 Digital output module 联系我们 Output 16 27.2×130×176 0.2 kg

Popular Yokogawa 型号s

型号 描述 Function System Compatibility 重量
AAI143-H50 High-speed analog input module Analog Input CENTUM VP/CS 3000 0.2 kg
AAI543-H00 HART analog input module Analog Input (HART) CENTUM VP/CS 3000 0.2 kg
AAI835-H00 Isolated universal input module Universal Input CENTUM VP 0.3 kg
AAR181-S00 Pulse input module Pulse Signal CENTUM VP/ProSafe-RS 0.2 kg
ADV551 Digital output module (relay) Relay Output CENTUM VP/CS 3000 0.25 kg
ACG10S Control network gateway module Network Gateway CENTUM VP 0.3 kg

公司信息

E-mail: [email protected]

Mobile:请通过邮件联系

Whatsapp:请通过邮件联系

Add: 中国福建省厦门市思明区吕岭路2号阿里山大厦,邮编:361006

我们的服务

我们专业提供工业自动化零部件,并附有一年质保。我们的工业自动化零部件销往全球。

我们能提供来自不同国家和制造商的设备及备件,解决您在多处的顾虑或质量问题,并具有极大的价格优势。

欢迎来电咨询更多产品详情。

产品保修与客户保障

保修详情
  • 2 年标准保修 – 涵盖材料和工艺缺陷
  • 可选延长保修 – 将保修期延长至 5 年
  • 现场技术支持 – 提供经过工厂培训的工程师服务
  • 更换计划 – 48 小时内优先更换
  • 持续的技术协助 – 所有产品的终身支持
质量合规
  • 100% 测试与验证 – 每件产品发货前均经过检查
  • ISO 9001 认证 – 遵守质量管理体系
  • 环境合规 – 符合 RoHS 和 CE 标准
  • 全球安全认证 – UL、cUL 及其他适用认证
  • 可追溯生产 – 完整的序列号和批次可追溯性
退换货政策
  • 30 天退货期 – 未使用产品的退款
  • 无补货费 – 退货处理不收取额外费用
  • 免费退货运费 – 针对有缺陷或错误的商品
  • 交叉发货支持 – 在更换期间最大限度地减少停机时间
  • 简单的 RMA 流程 – 提供在线退货授权
客户权益与支持
  • 价格匹配保证 – 30 天产品价格保护
  • 预留库存 – 为回头客提供优先库存
  • 技术培训 – 提供在线和现场产品培训课程
  • 集成协助 – 为 PLC/DCS 集成提供工程支持
  • 旧型号产品支持 – 为已停产的模块持续提供服务
保修条款与条件
涵盖项目:
  • 材料和工艺方面的制造缺陷
  • 正常使用下的组件故障
  • 固件或软件问题(提供更新)
  • 文档中的错误或遗漏
除外条款:
  • 错误安装或不当使用
  • 未经授权的修改或维修
  • 事故、误用或疏忽造成的损坏
  • 随时间的正常磨损
重要说明:
  • 所有保修或退货请求均需提供购买凭证
  • 退货时应保留原包装
  • 定制配置或特殊订单产品可能有不同的退货条件
  • 国际运输可能需要考虑额外的处理或运输事项

技术文档

Check out Yokogawa ADM11-S3 联系我们 Input Module latest technical documentation.

客户评价

发表评论

请通过邮件联系 [email protected] 请通过邮件联系 Follow us on Facebook Subscribe on YouTube