产品介绍
The Yokogawa A2SAM105 is a high-performance current and voltage input adapter designed for use with Yokogawa’s advanced automation systems. This adapter is part / the A2 series and is engineered to provide accurate and reliable measurement / both current and voltage signals. The A2SAM105 is commonly integrated into distributed control systems (DCS), supervisory control and data acquisition (SCADA) systems, and other industrial applications where precision signal conversion and signal conditioning are required.
With its ability to handle both current (4-20 mA) and voltage (0-10V) inputs, the A2SAM105 is an ideal solution for measuring and monitoring electrical signals in a variety / industrial and process control environments. Its compatibility with Yokogawa’s CENTUM series makes it easy to integrate into existing automation setups, providing efficient and real-time data acquisition and processing capabilities.
产品规格:
| Parameter | Details |
|---|---|
| Module Type | Current/Voltage Input Adapter |
| Input Types | Voltage (0-10V), Current (4-20mA) |
| Input Range | 0-10V, 4-20mA |
| Output Type | Digital Output |
| Resolution | 16-bit resolution |
| Accuracy | ±0.05% / full scale |
| Power Supply | 24V DC ±10% |
| Operating Temperature | -20°C to +60°C |
| Storage Temperature | -40°C to +85°C |
| Humidity Range | 5% to 95% (non-condensing) |
| Dimensions (LxWxH) | 130 x 12.8 x 40 mm |
| 重量 | 0.1 kg |
| Mounting Type | DIN Rail Mounting |
| Isolation | 1500V DC (input to output) |
| Sampling Rate | 100ms per channel |
Applications:
The Yokogawa A2SAM105 Current/Voltage Input Adapter is designed for use in a wide range / applications where accurate signal conversion from analog to digital is critical. Typical applications include:
- Process Control: Used in process control systems for precise monitoring / variables such as pressure, temperature, and flow.
- Energy Management: Helps in managing energy consumption and optimizing electrical systems by acquiring current and voltage data.
- SCADA Systems: The module is used in supervisory control and data acquisition systems to collect and monitor analog signals for real-time decision-making.
- Manufacturing Automation: Utilized in factory automation systems to measure and control processes like production lines, assembly operations, and robotics.
- Power Distribution Systems: Used in power plants, substations, and other energy-related applications for monitoring electrical parameters like voltage and current.
- Measurement & Calibration: Ideal for accurate measurements in laboratory settings, instrument calibration, and industrial diagnostics.
- Environmental Monitoring: Used to monitor and control environmental parameters like temperature, humidity, and air quality in industrial environments.
Advantages:
- High Accuracy: The A2SAM105 provides high-precision measurements with an accuracy / ±0.05% / full scale, making it ideal for critical applications.
- Flexible Input Options: 支持s both current (4-20mA) and voltage (0-10V) inputs, ensuring flexibility to meet various application needs.
- Built-in Isolation: The module includes 1500V DC isolation between input and output, ensuring protection against electrical surges and transients.
- Compact Design: Its compact form factor makes it easy to install in industrial panels, and the DIN rail mounting option simplifies the installation process.
- Wide Operating Temperature Range: The module operates within a wide temperature range / -20°C to +60°C, making it suitable for harsh industrial environments.
- Seamless Integration: Fully compatible with Yokogawa’s CENTUM DCS systems, enabling easy integration and communication within control systems.
- Durable: Designed for long-term reliability, the module is capable / withstanding demanding environments and /fers excellent performance even under challenging conditions.
- Low Power Consumption: With a low power requirement / 24V DC, the A2SAM105 is energy-efficient, reducing operational costs.
Latest News:
-
“Yokogawa Introduces A2SAM105 Current/Voltage Input Adapter for Precision Process Control”
An announcement covering the release / the A2SAM105, emphasizing its role in precision process control and its compatibility with Yokogawa’s automation systems. -
“The Yokogawa A2SAM105: The Ideal Solution for Power Distribution Systems”
A detailed look at how the A2SAM105 is helping optimize energy management and control in power distribution systems. -
“Yokogawa’s A2SAM105: A Flexible Input Adapter for Industrial Automation”
A report on the versatility / the A2SAM105, highlighting its applications in both manufacturing automation and energy management. -
“Ensuring Real-Time Data Acquisition with Yokogawa’s A2SAM105 Input Adapter”
Coverage / how the A2SAM105 enhances SCADA systems by providing accurate and reliable data acquisition in real-time.
常见问题 (FAQ):
-
What types / input signals does the A2SAM105 accept?
The A2SAM105 accepts voltage signals (0-10V) and current signals (4-20mA). -
What is the accuracy / the A2SAM105 module?
The module /fers an accuracy / ±0.05% / full scale. -
How many input channels does the A2SAM105 support?
The module supports 4 input channels for analog signals. -
What is the operating temperature range / the A2SAM105?
The module operates within a temperature range / -20°C to +60°C. -
What type / mounting is available for the A2SAM105?
The module supports DIN rail mounting, making installation easy and secure. -
What is the power supply requirement for the A2SAM105?
The A2SAM105 operates on a 24V DC power supply with a ±10% tolerance. -
Is the A2SAM105 isolated from electrical surges?
Yes, the A2SAM105 provides 1500V DC isolation between the input and output. -
What is the weight / the A2SAM105 module?
The A2SAM105 weighs approximately 0.1 kg. -
Can the A2SAM105 be integrated with Yokogawa’s CENTUM DCS systems?
Yes, the module is fully compatible with Yokogawa’s CENTUM DCS systems. -
In what types / industries is the A2SAM105 used?
The A2SAM105 is used in process control, energy management, SCADA systems, manufacturing automation, power distribution, and environmental monitoring.
Related 型号s:
| 型号 | 描述 | Input Types | Channels | Resolution | Accuracy |
|---|---|---|---|---|---|
| A2SAM106 | Current/Voltage Input Adapter | Voltage, Current | 4 | 16-bit | ±0.05% |
| A2SAM107 | Advanced Input Adapter | Voltage, Current | 8 | 16-bit | ±0.05% |
| A2SAM108 | Isolated Current/Voltage Input Adapter | Voltage, Current | 4 | 16-bit | ±0.1% |
| A2SAM110 | High-Performance Input Adapter | Voltage, Current | 4 | 16-bit | ±0.05% |
| A2SAM120 | Low-Noise Current/Voltage Input Adapter | Voltage, Current | 4 | 16-bit | ±0.05% |
Popular Yokogawa 型号s:
| 型号 | 描述 | Input Types | Channels | Resolution | Accuracy |
|---|---|---|---|---|---|
| CS3000 DCS | Distributed Control System | Digital/Analog | Multi | 16-bit | ±0.05% |
| GP10 | Process Controller | Analog/Digital | Multi | 16-bit | ±0.1% |
| DPharp EJA Series | Pressure Transmitter | Pressure | Single | 24-bit | ±0.025% |
| RotaShear | Flow Transmitter | Flow | Single | 16-bit | ±0.1% |
| ProSafe-RS | Safety Instrumented System | Digital/Analog | Multi | 16-bit | ±0.1% |
| Yokogawa Vnet/IP | Industrial Communication Network | Digital/Analog | Multi | 16-bit | ±0.1% |
| YA1000 Series | PID Controllers | Analog | Single | 16-bit | ±0.1% |
| DX1000 Series | Process Controllers | Analog/Digital | Multi | 16-bit | ±0.1% |
| A0A0X Series | Temperature Control Systems | Temperature | Single | 16-bit | ±0.1% |
| EXA Series | Process Analyzers | Gas/Pressure/Temperature | Multi | 16-bit | ±0.05% |
公司信息
E-mail: [email protected]
Mobile:请通过邮件联系
Whatsapp:请通过邮件联系
Add: 中国福建省厦门市思明区吕岭路2号阿里山大厦,邮编:361006
我们的服务
我们专业提供工业自动化零部件,并附有一年质保。我们的工业自动化零部件销往全球。
我们能提供来自不同国家和制造商的设备及备件,解决您在多处的顾虑或质量问题,并具有极大的价格优势。
欢迎来电咨询更多产品详情。