报价 (0)

Schneider TSXAEY810 Analog Input Module

产品介绍 The Schneider TSXAEY810 is a precision-engineered 8-channel analog input module designed specifically for use within the Modicon Premium programmable logic controller (PLC) system

零件号: 930
TAGS:
有库存
Schneider TSXAEY810 Analog Input Module

产品规格

发布时间Jul 07, 2026
制造商 施耐德
型号 TSXAEY810
零件号 IN930
状态100% 全新
发货港口中国厦门
交货时间1-3 个工作日
证书COO
快递合作伙伴DHL, UPS, TNT, FedEx and EMS.
保修 1 年
单价
$759.00
USD / 单位
-
+
最小起订量: 1 件
0.0


运输信息
订单满额免运费 $5,000
美国东部时间下午 3 点前下单,当日发货
提供国际运输
Schneider TSXAEY810 Analog Input Module Schneider TSXAEY810 Analog Input Module Schneider TSXAEY810 Analog Input Module Schneider TSXAEY810 Analog Input Module

产品介绍

The Schneider TSXAEY810 is a precision-engineered 8-channel analog input module designed specifically for use within the Modicon Premium programmable logic controller (PLC) system. Engineered to interface seamlessly with industrial automation and process control systems, the TSXAEY810 provides high-resolution input signal acquisition for current-based signals.

This module is particularly well-suited for applications that demand isolated, accurate, and stable analog input readings. It supports a range / current signals including the standard 4-20 mA, and /fers channel-to-channel isolation to protect against signal interference and electrical faults. With durable construction, strong EMC compliance, and easy integration through 单位y Pro / EcoStruxure Control Expert, this module is a staple in control environments that require precision and resilience.


产品规格

Parameter 描述
Product 型号 TSXAEY810
制造商 Schneider Electric
Product Type Analog Input Module
Number / Channels 8 Isolated Analog Inputs
Input Signal Type Current
支持ed Input Range 0-20 mA / 4-20 mA
Resolution 12-bit
Input Impedance 250 Ohms (typical)
Accuracy ±0.5% / full scale
Conversion Time Approx. 4 ms per channel
Isolation Voltage 500 V (channel-to-bus and channel-to-channel)
Diagnostic Features Open loop detection, signal out-/-range alert
Power Supply Via backplane bus (no external supply required)
Mounting Type DIN rail (standard rack-mounted)
Operating Temperature Range 0°C to +60°C
Storage Temperature Range -25°C to +70°C
Relative Humidity 5% to 95% (non-condensing)
Configuration S/tware 单位y Pro / EcoStruxure Control Expert
Dimensions (W x H x D) 55 x 180 x 260 mm
重量 0.31 kg
Series Modicon Premium
Compatible PLCs TSX Premium CPUs (e.g., TSXP574634M)

Applications

The Schneider TSXAEY810 module is widely adopted across industries that require accurate monitoring / analog current inputs. Some key application areas include:

  • Process Automation: Used to acquire signals from transmitters measuring pressure, level, temperature, and flow.

  • Manufacturing Plants: 支持s precise monitoring in batch processing, production lines, and machinery status.

  • Building Management Systems (BMS): Interfaces with environmental sensors in HVAC and lighting control systems.

  • Water and Wastewater Treatment: Collects data from flow meters and level sensors for process control and monitoring.

  • Power Plants and Energy Sector: Acquires current signals from metering and control equipment.

  • OEM Equipment Integration: Ideal for machine builders needing reliable analog signal input modules.


Product Advantages

  • True Channel Isolation: Each analog input is electrically isolated from the others, significantly reducing the risk / cross-talk and interference.

  • Rugged Industrial Design: Withstands high EMI/RFI and vibration, suitable for tough industrial environments.

  • High Signal Accuracy: Designed to meet stringent accuracy requirements for analog signal measurements.

  • Fast Signal Acquisition: Each channel is converted in just a few milliseconds, ensuring near-real-time monitoring.

  • S/tware-Friendly: Easily integrated and configured through Schneider’s user-friendly 单位y Pro / EcoStruxure s/tware suite.

  • Compact and Scalable: The slim pr/ile saves cabinet space and supports scalable system architecture.

  • Reliable Diagnostics: Built-in features such as wire-break detection and signal range monitoring improve maintenance response and system reliability.


常见问题 (FAQ)

  1. What type / analog signals does the TSXAEY810 support?
    It supports standard 0-20 mA and 4-20 mA current loop signals.

  2. Can it be used with voltage input devices?
    No, this module is designed specifically for current signal input only.

  3. Is there individual channel isolation?
    Yes, each / the 8 channels is galvanically isolated from the others and from the backplane bus.

  4. Can I use this module in a Modicon Quantum PLC system?
    No, it is compatible only with the Modicon Premium series.

  5. How do I configure the TSXAEY810 module?
    Configuration is done via Schneider’s 单位y Pro or EcoStruxure Control Expert s/tware.

  6. Does it support HART communication?
    No, it does not support HART protocol. It is purely an analog input module.

  7. Is the module hot-swappable?
    No, it should not be inserted or removed while the PLC is powered on.

  8. What is the isolation voltage level?
    It provides up to 500 V isolation between channels and to the system bus.

  9. Does the module have onboard diagnostics?
    Yes, it features signal out-/-range detection and open-loop diagnostics.

  10. What’s the difference between TSXAEY800 and TSXAEY810?
    Both are similar, but the TSXAEY810 may feature slight hardware or firmware enhancements depending on production batch. Always check compatibility with the CPU model and s/tware version.


Related 型号s (Same Series / Functionality)

型号 描述 Channels Input Type Notes
TSXAEY800 8-Ch Analog Input Module 8 Current (4-20 mA) Earlier model / TSXAEY810
TSXAEY1600 16-Ch Analog Input Module 16 Current High-density analog input
TSXASY410 4-Ch Analog Output Module 4 Voltage/Current Complementary analog output
TSXDEY64D2K 64-Ch Digital Input Module 64 Digital High-density digital inputs
TSXDSY32T2K 32-Ch Digital Output Module 32 Digital Digital signal output
TSXP574634M Premium PLC CPU Module CPU Compatible CPU

Popular 型号s from Schneider Electric

型号 描述 Type Compatibility
BMXAMI0410 4-Ch Analog Input Module for Modicon M340 Analog Input Modicon M340
TM5SAI4F 4-Ch Analog Input Module for TM5 Analog Input Modicon TM5
BMXDDI1602 16-Ch Digital Input Module Digital Input Modicon M340
TM241CE40T Logic Controller with Ethernet & I/O PLC Controller EcoStruxure Machine Expert
BMXAMO0410 4-Ch Analog Output Module Analog Output Modicon M340
TM3AI8 8-Ch Analog Input Module for TM3 Series Analog Input Compatible with M221/M241 PLCs

公司信息

E-mail: [email protected]

Mobile:请通过邮件联系

Whatsapp:请通过邮件联系

Add: 中国福建省厦门市思明区吕岭路2号阿里山大厦,邮编:361006

我们的服务

我们专业提供工业自动化零部件,并附有一年质保。我们的工业自动化零部件销往全球。

我们能提供来自不同国家和制造商的设备及备件,解决您在多处的顾虑或质量问题,并具有极大的价格优势。

欢迎来电咨询更多产品详情。

产品保修与客户保障

保修详情
  • 2 年标准保修 – 涵盖材料和工艺缺陷
  • 可选延长保修 – 将保修期延长至 5 年
  • 现场技术支持 – 提供经过工厂培训的工程师服务
  • 更换计划 – 48 小时内优先更换
  • 持续的技术协助 – 所有产品的终身支持
质量合规
  • 100% 测试与验证 – 每件产品发货前均经过检查
  • ISO 9001 认证 – 遵守质量管理体系
  • 环境合规 – 符合 RoHS 和 CE 标准
  • 全球安全认证 – UL、cUL 及其他适用认证
  • 可追溯生产 – 完整的序列号和批次可追溯性
退换货政策
  • 30 天退货期 – 未使用产品的退款
  • 无补货费 – 退货处理不收取额外费用
  • 免费退货运费 – 针对有缺陷或错误的商品
  • 交叉发货支持 – 在更换期间最大限度地减少停机时间
  • 简单的 RMA 流程 – 提供在线退货授权
客户权益与支持
  • 价格匹配保证 – 30 天产品价格保护
  • 预留库存 – 为回头客提供优先库存
  • 技术培训 – 提供在线和现场产品培训课程
  • 集成协助 – 为 PLC/DCS 集成提供工程支持
  • 旧型号产品支持 – 为已停产的模块持续提供服务
保修条款与条件
涵盖项目:
  • 材料和工艺方面的制造缺陷
  • 正常使用下的组件故障
  • 固件或软件问题(提供更新)
  • 文档中的错误或遗漏
除外条款:
  • 错误安装或不当使用
  • 未经授权的修改或维修
  • 事故、误用或疏忽造成的损坏
  • 随时间的正常磨损
重要说明:
  • 所有保修或退货请求均需提供购买凭证
  • 退货时应保留原包装
  • 定制配置或特殊订单产品可能有不同的退货条件
  • 国际运输可能需要考虑额外的处理或运输事项

技术文档

Check out Schneider TSXAEY810 Analog Input Module latest technical documentation.

客户评价

发表评论

请通过邮件联系 [email protected] 请通过邮件联系 Follow us on Facebook Subscribe on YouTube