产品介绍
The Honeywell MC-TAMT13 51309213-125 Low Level Analog Input Multiplexer Module is a high-performance device designed to efficiently expand the analog input capacity / Honeywell control systems. This module sequentially routes multiple low-level analog signals to a single input channel on a distributed control system (DCS), reducing wiring complexity while maintaining signal integrity.
The MC-TAMT13 is particularly suitable for precise measurement and monitoring applications where low-level signals, such as millivolt-range sensors and thermocouples, need to be integrated into process automation systems. It is fully compatible with Honeywell Experion PKS, TDC 3000, and other DCS platforms, enabling smooth integration and enhanced system scalability. The module ensures minimal crosstalk, high accuracy, and reliable performance even in industrial environments with electrical noise or harsh conditions.
Technical Specifications
| Parameter | Specification |
|---|---|
| 型号 | MC-TAMT13 51309213-125 |
| Type | Low Level Analog Input Multiplexer Module |
| Input Channels | 16 channels |
| Input Signal Range | ±50 mV, ±100 mV, 0–20 mA, 4–20 mA |
| Switching Method | Sequential analog multiplexing |
| Accuracy | ±0.1% / full scale |
| Crosstalk | < 0.05% |
| Isolation | Channel-to-channel: 500 V RMS |
| Operating Temperature | 0°C to 60°C |
| Storage Temperature | -40°C to 85°C |
| Humidity | 5–95% non-condensing |
| Power Supply | 24 V DC |
| Power Consumption | 6 W typical |
| Response Time | 100 ms typical |
| Diagnostics | Channel health monitoring, open/short detection |
| Mounting | DIN rail or rack-mountable |
| Dimensions (H x W x D) | 130 × 45 × 160 mm |
| 重量 | 0.72 kg |
| Communication Interface | Compatible with 霍尼韦尔 I/O backplane |
Applications
The MC-TAMT13 module is widely applied in industrial process automation and measurement scenarios:
-
Multiplexing multiple low-level analog signals for integration into 霍尼韦尔 systems.
-
Monitoring thermocouples and millivolt-range sensors in chemical, petrochemical, and pharmaceutical processes.
-
Aggregating small current loop signals in oil and gas production systems.
-
Facilitating advanced process control strategies by reducing the number / dedicated input channels.
-
Integration into power generation systems for precise analog signal measurement.
-
支持ing industrial test benches and laboratories requiring accurate low-level analog acquisition.
Advantages
-
High Accuracy: Maintains ±0.1% full-scale accuracy for precise signal acquisition.
-
Minimal Crosstalk: Crosstalk between channels is below 0.05%, ensuring clean signal transmission.
-
Versatile Input 支持: Handles ±50 mV, ±100 mV, 0–20 mA, and 4–20 mA signals.
-
Robust Diagnostics: Built-in channel health monitoring and open/short detection facilitate preventive maintenance.
-
Flexible Mounting: Can be mounted on DIN rails or racks to fit various panel layouts.
-
Reliable System Integration: Compatible with Experion PKS, TDC 3000, and other 霍尼韦尔 platforms.
-
Space and Cost Efficient: Reduces wiring and input channel requirements, saving panel space and reducing hardware costs.
FAQ
-
How many channels does the MC-TAMT13 support?
It supports 16 independent low-level analog input channels, allowing multiple signals to be routed to a single DCS input. -
Which input signal types can the module handle?
The module accepts ±50 mV, ±100 mV, 0–20 mA, and 4–20 mA signals, covering common voltage and small current loop sensors. -
What is the module’s typical accuracy?
It provides ±0.1% full-scale accuracy, ensuring precise measurement for low-level analog signals. -
What is the crosstalk between channels?
Crosstalk is less than 0.05%, keeping each channel’s signal independent and reliable. -
Is channel isolation provided?
Yes, each channel is isolated up to 500 V RMS to prevent interference between signals. -
What is the typical response time?
The response time is around 100 ms per channel, enabling quick sequential signal measurement. -
Does the module provide diagnostics?
Yes, it includes channel health monitoring and open/short detection to support maintenance. -
What mounting options are available?
It can be mounted on a DIN rail or rack, /fering flexibility for panel installations. -
What power supply does the module require?
The module operates on 24 V DC with typical power consumption / 6 W. -
Which Honeywell systems is it compatible with?
It works with Experion PKS, TDC 3000, and other DCS I/O backplane systems for smooth integration.
Related 型号s
| 型号 | 描述 | Channels | Input Types |
|---|---|---|---|
| MC-TAMT01 | Low-Level Analog Multiplexer Module | 8 | ±50 mV, ±100 mV, 0–20 mA |
| MC-TAMT02 | Low-Level Analog Multiplexer Module | 12 | ±50 mV, ±100 mV, 4–20 mA |
| MC-TAMT03 | Low-Level Analog Multiplexer Module | 16 | ±50 mV, ±100 mV, 0–20 mA |
| MC-TAMT04 | High-Precision Analog Multiplexer Module | 16 | ±50 mV, ±100 mV, 0–20 mA |
| MC-TAMT05 | Thermocouple-focused Analog Multiplexer | 16 | Thermocouple types J, K, T |
| MC-TAMT06 | Redundant Low-Level Analog Multiplexer Module | 16 | ±50 mV, ±100 mV, 4–20 mA |
Popular Honeywell 型号s
| 型号 | 描述 | Channels | Input Types |
|---|---|---|---|
| UDC3200 | Universal Digital Controller | N/A | Voltage, Current |
| HC900 | Hybrid Controller | N/A | Analog, Digital |
| Experion PKS I/O | Distributed I/O Modules | 8–16 | Current, Voltage, Thermocouple |
| TDC 3000 HART I/O | HART-compatible Input/Output Module | 8 | Current, Voltage |
| SmartLine Transmitters | Pressure/Flow/Temperature Transmitters | N/A | Current, Voltage |
| SCADA I/O Modules | Supervisory Control Input/Output Modules | 8–16 | Analog and Digital |
公司信息
E-mail: [email protected]
Mobile:请通过邮件联系
Whatsapp:请通过邮件联系
Add: 中国福建省厦门市思明区吕岭路2号阿里山大厦,邮编:361006
我们的服务
我们专业提供工业自动化零部件,并附有一年质保。我们的工业自动化零部件销往全球。
我们能提供来自不同国家和制造商的设备及备件,解决您在多处的顾虑或质量问题,并具有极大的价格优势。
欢迎来电咨询更多产品详情。