Honeywell MC-TAMT13 51309213-125 Low Level Analog Input Multiplexer Module

产品介绍 The Honeywell MC-TAMT13 51309213-125 Low Level Analog Input Multiplexer Module is a high-performance device designed to efficiently expand the analog input capacity / Honeywell c

零件号: 2623 有库存
Honeywell MC-TAMT13 51309213-125 Low Level Analog Input Multiplexer Module

产品规格

发布时间Jul 07, 2026
制造商 霍尼韦尔
型号 MC-TAMT13 51309213-125
零件号 IN2623
状态100% 全新
发货港口中国厦门
交货时间1-3 个工作日
证书COO
快递合作伙伴DHL, UPS, TNT, FedEx and EMS.
保修 1 年
单价
$309.00
USD / 单位
-
+
最小起订量: 1 件
0.0


运输信息
订单满额免运费 $5,000
美国东部时间下午 3 点前下单,当日发货
提供国际运输
Honeywell MC-TAMT13 51309213-125 Low Level Analog Input Multiplexer Module Honeywell MC-TAMT13 51309213-125 Low Level Analog Input Multiplexer Module Honeywell MC-TAMT13 51309213-125 Low Level Analog Input Multiplexer Module Honeywell MC-TAMT13 51309213-125 Low Level Analog Input Multiplexer Module

产品介绍

The Honeywell MC-TAMT13 51309213-125 Low Level Analog Input Multiplexer Module is a high-performance device designed to efficiently expand the analog input capacity / Honeywell control systems. This module sequentially routes multiple low-level analog signals to a single input channel on a distributed control system (DCS), reducing wiring complexity while maintaining signal integrity.

The MC-TAMT13 is particularly suitable for precise measurement and monitoring applications where low-level signals, such as millivolt-range sensors and thermocouples, need to be integrated into process automation systems. It is fully compatible with Honeywell Experion PKS, TDC 3000, and other DCS platforms, enabling smooth integration and enhanced system scalability. The module ensures minimal crosstalk, high accuracy, and reliable performance even in industrial environments with electrical noise or harsh conditions.


Technical Specifications

Parameter Specification
型号 MC-TAMT13 51309213-125
Type Low Level Analog Input Multiplexer Module
Input Channels 16 channels
Input Signal Range ±50 mV, ±100 mV, 0–20 mA, 4–20 mA
Switching Method Sequential analog multiplexing
Accuracy ±0.1% / full scale
Crosstalk < 0.05%
Isolation Channel-to-channel: 500 V RMS
Operating Temperature 0°C to 60°C
Storage Temperature -40°C to 85°C
Humidity 5–95% non-condensing
Power Supply 24 V DC
Power Consumption 6 W typical
Response Time 100 ms typical
Diagnostics Channel health monitoring, open/short detection
Mounting DIN rail or rack-mountable
Dimensions (H x W x D) 130 × 45 × 160 mm
重量 0.72 kg
Communication Interface Compatible with 霍尼韦尔 I/O backplane

Applications

The MC-TAMT13 module is widely applied in industrial process automation and measurement scenarios:

  • Multiplexing multiple low-level analog signals for integration into 霍尼韦尔 systems.

  • Monitoring thermocouples and millivolt-range sensors in chemical, petrochemical, and pharmaceutical processes.

  • Aggregating small current loop signals in oil and gas production systems.

  • Facilitating advanced process control strategies by reducing the number / dedicated input channels.

  • Integration into power generation systems for precise analog signal measurement.

  • 支持ing industrial test benches and laboratories requiring accurate low-level analog acquisition.


Advantages

  • High Accuracy: Maintains ±0.1% full-scale accuracy for precise signal acquisition.

  • Minimal Crosstalk: Crosstalk between channels is below 0.05%, ensuring clean signal transmission.

  • Versatile Input 支持: Handles ±50 mV, ±100 mV, 0–20 mA, and 4–20 mA signals.

  • Robust Diagnostics: Built-in channel health monitoring and open/short detection facilitate preventive maintenance.

  • Flexible Mounting: Can be mounted on DIN rails or racks to fit various panel layouts.

  • Reliable System Integration: Compatible with Experion PKS, TDC 3000, and other 霍尼韦尔 platforms.

  • Space and Cost Efficient: Reduces wiring and input channel requirements, saving panel space and reducing hardware costs.


FAQ

  1. How many channels does the MC-TAMT13 support?
    It supports 16 independent low-level analog input channels, allowing multiple signals to be routed to a single DCS input.

  2. Which input signal types can the module handle?
    The module accepts ±50 mV, ±100 mV, 0–20 mA, and 4–20 mA signals, covering common voltage and small current loop sensors.

  3. What is the module’s typical accuracy?
    It provides ±0.1% full-scale accuracy, ensuring precise measurement for low-level analog signals.

  4. What is the crosstalk between channels?
    Crosstalk is less than 0.05%, keeping each channel’s signal independent and reliable.

  5. Is channel isolation provided?
    Yes, each channel is isolated up to 500 V RMS to prevent interference between signals.

  6. What is the typical response time?
    The response time is around 100 ms per channel, enabling quick sequential signal measurement.

  7. Does the module provide diagnostics?
    Yes, it includes channel health monitoring and open/short detection to support maintenance.

  8. What mounting options are available?
    It can be mounted on a DIN rail or rack, /fering flexibility for panel installations.

  9. What power supply does the module require?
    The module operates on 24 V DC with typical power consumption / 6 W.

  10. Which Honeywell systems is it compatible with?
    It works with Experion PKS, TDC 3000, and other DCS I/O backplane systems for smooth integration.


Related 型号s

型号 描述 Channels Input Types
MC-TAMT01 Low-Level Analog Multiplexer Module 8 ±50 mV, ±100 mV, 0–20 mA
MC-TAMT02 Low-Level Analog Multiplexer Module 12 ±50 mV, ±100 mV, 4–20 mA
MC-TAMT03 Low-Level Analog Multiplexer Module 16 ±50 mV, ±100 mV, 0–20 mA
MC-TAMT04 High-Precision Analog Multiplexer Module 16 ±50 mV, ±100 mV, 0–20 mA
MC-TAMT05 Thermocouple-focused Analog Multiplexer 16 Thermocouple types J, K, T
MC-TAMT06 Redundant Low-Level Analog Multiplexer Module 16 ±50 mV, ±100 mV, 4–20 mA

Popular Honeywell 型号s

型号 描述 Channels Input Types
UDC3200 Universal Digital Controller N/A Voltage, Current
HC900 Hybrid Controller N/A Analog, Digital
Experion PKS I/O Distributed I/O Modules 8–16 Current, Voltage, Thermocouple
TDC 3000 HART I/O HART-compatible Input/Output Module 8 Current, Voltage
SmartLine Transmitters Pressure/Flow/Temperature Transmitters N/A Current, Voltage
SCADA I/O Modules Supervisory Control Input/Output Modules 8–16 Analog and Digital

公司信息

E-mail: [email protected]

Mobile:请通过邮件联系

Whatsapp:请通过邮件联系

Add: 中国福建省厦门市思明区吕岭路2号阿里山大厦,邮编:361006

我们的服务

我们专业提供工业自动化零部件,并附有一年质保。我们的工业自动化零部件销往全球。

我们能提供来自不同国家和制造商的设备及备件,解决您在多处的顾虑或质量问题,并具有极大的价格优势。

欢迎来电咨询更多产品详情。

产品保修与客户保障

保修详情
  • 2 年标准保修 – 涵盖材料和工艺缺陷
  • 可选延长保修 – 将保修期延长至 5 年
  • 现场技术支持 – 提供经过工厂培训的工程师服务
  • 更换计划 – 48 小时内优先更换
  • 持续的技术协助 – 所有产品的终身支持
质量合规
  • 100% 测试与验证 – 每件产品发货前均经过检查
  • ISO 9001 认证 – 遵守质量管理体系
  • 环境合规 – 符合 RoHS 和 CE 标准
  • 全球安全认证 – UL、cUL 及其他适用认证
  • 可追溯生产 – 完整的序列号和批次可追溯性
退换货政策
  • 30 天退货期 – 未使用产品的退款
  • 无补货费 – 退货处理不收取额外费用
  • 免费退货运费 – 针对有缺陷或错误的商品
  • 交叉发货支持 – 在更换期间最大限度地减少停机时间
  • 简单的 RMA 流程 – 提供在线退货授权
客户权益与支持
  • 价格匹配保证 – 30 天产品价格保护
  • 预留库存 – 为回头客提供优先库存
  • 技术培训 – 提供在线和现场产品培训课程
  • 集成协助 – 为 PLC/DCS 集成提供工程支持
  • 旧型号产品支持 – 为已停产的模块持续提供服务
保修条款与条件
涵盖项目:
  • 材料和工艺方面的制造缺陷
  • 正常使用下的组件故障
  • 固件或软件问题(提供更新)
  • 文档中的错误或遗漏
除外条款:
  • 错误安装或不当使用
  • 未经授权的修改或维修
  • 事故、误用或疏忽造成的损坏
  • 随时间的正常磨损
重要说明:
  • 所有保修或退货请求均需提供购买凭证
  • 退货时应保留原包装
  • 定制配置或特殊订单产品可能有不同的退货条件
  • 国际运输可能需要考虑额外的处理或运输事项

技术文档

Check out Honeywell MC-TAMT13 51309213-125 Low Level Analog Input Multiplexer Module latest technical documentation.

客户评价

发表评论

请通过邮件联系 [email protected] 请通过邮件联系 Follow us on Facebook Subscribe on YouTube