报价 (0)

Honeywell FS-TSGAS-1624 Safety Fire Detector Input FTA

Product Overview The Honeywell FS-TSGAS-1624 Safety Fire Detector Input FTA is a field termination assembly (FTA) specifically designed for use in fire detection and safety instrumented systems (SIS)

零件号: 3521 有库存
Honeywell FS-TSGAS-1624 Safety Fire Detector Input FTA

产品规格

发布时间Jul 07, 2026
制造商 霍尼韦尔
型号 FS-TSGAS-1624
零件号 IN3521
状态100% 全新
发货港口中国厦门
交货时间1-3 个工作日
证书COO
快递合作伙伴DHL, UPS, TNT, FedEx and EMS.
保修 1 年
单价
$1,849.00
USD / 单位
-
+
最小起订量: 1 件
0.0


运输信息
订单满额免运费 $5,000
美国东部时间下午 3 点前下单,当日发货
提供国际运输
Honeywell FS-TSGAS-1624 Safety Fire Detector Input FTA Honeywell FS-TSGAS-1624 Safety Fire Detector Input FTA Honeywell FS-TSGAS-1624 Safety Fire Detector Input FTA Honeywell FS-TSGAS-1624 Safety Fire Detector Input FTA

Product Overview

The Honeywell FS-TSGAS-1624 Safety Fire Detector Input FTA is a field termination assembly (FTA) specifically designed for use in fire detection and safety instrumented systems (SIS). It acts as the interface between fire detectors and the Honeywell Safety Manager (SM) or Fail Safe Controller (FSC). The FS-TSGAS-1624 provides secure, reliable communication for fire detection signals, enabling quick and accurate responses to fire events.

With its SIL 3 certification, this module is suitable for critical safety applications where fire detection systems are integrated into broader process safety management. The FS-TSGAS-1624 is designed to handle inputs from multiple types / fire detectors, including ionization, photoelectric, and smoke detectors, and ensures accurate transmission / alarm signals to the central safety system.


Key Features

  • SIL 3 Certified: Meets IEC 61508 safety integrity level for use in safety systems

  • Multiple Fire Detector Compatibility: 支持s a wide range / fire detectors (ionization, photoelectric, smoke)

  • Redundant and Reliable: Ideal for use in redundant configurations for enhanced fault tolerance

  • Direct Interface with Honeywell Safety Systems: Fully integrates with Honeywell Safety Manager and FSC systems

  • Field-Terminated: Simplifies wiring and installation with field termination capabilities

  • Compact and Modular: Space-efficient design for integration into control panels and safety cabinets

  • LED Indicators: Provides clear status indicators for operational and fault states

  • Low Power Consumption: Designed to minimize power use while maintaining high performance


Technical Specifications

Parameter Specification
型号 Number FS-TSGAS-1624
Product Type Fire Detector Input Field Termination Assembly (FTA)
Input Type Compatible with ionization, photoelectric, and smoke detectors
SIL Certification SIL 3 (IEC 61508)
Operating Voltage 24 VDC (typically)
Communication Protocol Honeywell proprietary communication with Safety Manager and FSC
Temperature Range -20°C to +60°C (-4°F to +140°F)
Humidity Range 5% to 95% RH, non-condensing
Mounting Type DIN rail mountable (35 mm)
Field Termination Yes
Protection Features Short-circuit, overvoltage, and reverse polarity protection
Status Indicators LED indicators for power, operation, and fault states
Dimensions 225 x 70 x 60 mm
重量 0.75 kg
Compliance CE, RoHS, UL, IEC 61508, IEC 61010

Industry Applications

  • Oil & Gas Industry: Fire detection for process equipment, pipelines, and refining operations

  • Power Generation: Ensuring fire safety in critical power plant components, turbines, and transformers

  • Pharmaceutical: Safety fire detection in sterile environments and process control systems

  • Chemical & Petrochemical: Monitoring and controlling fire hazards in chemical plants and refineries

  • Water & Wastewater Treatment: Fire safety in treatment plants and storage facilities

  • Mining & Metals: Ensuring fire safety in high-risk environments such as furnaces and conveyors


Product Advantages

  • Safety-Certified: Fully SIL 3 compliant for high-integrity fire safety applications

  • Wide Compatibility: Works with a variety / fire detectors, making it adaptable to different safety needs

  • Efficient Field Termination: Simplifies installation and maintenance with direct connection to fire detectors

  • Enhanced Reliability: Built for use in critical applications where system uptime is crucial

  • Compact Form Factor: Easy to integrate into control cabinets with limited space

  • Clear Diagnostic Indicators: LEDs /fer real-time feedback on module health and performance

  • Reduced Power Consumption: Power-efficient design, minimizing energy costs in continuous operation


常见问题 (FAQ)

  1. Q: What types / fire detectors are supported?
    A: It supports ionization, photoelectric, and smoke detectors for fire detection.

  2. Q: Is the FS-TSGAS-1624 SIL 3 certified?
    A: Yes, it is certified to SIL 3 according to IEC 61508 standards.

  3. Q: How does the FS-TSGAS-1624 communicate with the Safety Manager or FSC?
    A: It communicates via Honeywell proprietary communication protocols with Safety Manager and FSC systems.

  4. Q: What is the power supply requirement for this module?
    A: It operates on 24 VDC, typically supplied from a central power 件 or safety power supply.

  5. Q: Can this module be used in redundant configurations?
    A: Yes, it is designed for redundant systems, ensuring fault tolerance and high availability.

  6. Q: What is the mounting method for this module?
    A: It is DIN rail mountable, which is a standard installation method for industrial control systems.

  7. Q: What is the temperature range for operation?
    A: The module operates in temperatures from -20°C to +60°C (-4°F to +140°F).

  8. Q: Does it include status LEDs for diagnostics?
    A: Yes, it has LED indicators to display power status, operational state, and fault conditions.

  9. Q: Is it easy to install and wire?
    A: Yes, it has field termination capabilities, simplifying installation and reducing wiring complexity.

  10. Q: In which industries is the FS-TSGAS-1624 typically used?
    A: It is commonly used in oil & gas, power generation, pharmaceutical, chemical, and water treatment industries.


Related or Similar Honeywell 型号s

型号 Number 描述
FS-TSGAS-1624R Redundant Fire Detector Input FTA for increased reliability
FC-TSM-0001 Safety Manager Fire and Gas Detection Module
FC-PSU-UNI2450 Universal 24 VDC Power Supply for Safety Systems
FS-TDIO-2430 Digital Input/Output Module for Fire and Gas Systems
FS-IOTA-R24 Redundant I/O Termination Assembly for fire systems
FC-TPSU-240516 24 VDC Power Supply Module for Fire Detection Systems

Popular Honeywell Automation Modules (Same 品牌)

型号 Number 描述
CC-TDIL01 Digital Input Module for C300
CC-PAIH01 HART Analog Input Module
CC-TDOR01 Relay Output Module
CC-TCNT01 Pulse Counter Module
CC-PDOB01 Digital Output Module
CC-TAOX11 Analog Output Module

公司信息

E-mail: [email protected]

Mobile:请通过邮件联系

Whatsapp:请通过邮件联系

Add: 中国福建省厦门市思明区吕岭路2号阿里山大厦,邮编:361006

我们的服务

我们专业提供工业自动化零部件,并附有一年质保。我们的工业自动化零部件销往全球。

我们能提供来自不同国家和制造商的设备及备件,解决您在多处的顾虑或质量问题,并具有极大的价格优势。

欢迎来电咨询更多产品详情。

产品保修与客户保障

保修详情
  • 2 年标准保修 – 涵盖材料和工艺缺陷
  • 可选延长保修 – 将保修期延长至 5 年
  • 现场技术支持 – 提供经过工厂培训的工程师服务
  • 更换计划 – 48 小时内优先更换
  • 持续的技术协助 – 所有产品的终身支持
质量合规
  • 100% 测试与验证 – 每件产品发货前均经过检查
  • ISO 9001 认证 – 遵守质量管理体系
  • 环境合规 – 符合 RoHS 和 CE 标准
  • 全球安全认证 – UL、cUL 及其他适用认证
  • 可追溯生产 – 完整的序列号和批次可追溯性
退换货政策
  • 30 天退货期 – 未使用产品的退款
  • 无补货费 – 退货处理不收取额外费用
  • 免费退货运费 – 针对有缺陷或错误的商品
  • 交叉发货支持 – 在更换期间最大限度地减少停机时间
  • 简单的 RMA 流程 – 提供在线退货授权
客户权益与支持
  • 价格匹配保证 – 30 天产品价格保护
  • 预留库存 – 为回头客提供优先库存
  • 技术培训 – 提供在线和现场产品培训课程
  • 集成协助 – 为 PLC/DCS 集成提供工程支持
  • 旧型号产品支持 – 为已停产的模块持续提供服务
保修条款与条件
涵盖项目:
  • 材料和工艺方面的制造缺陷
  • 正常使用下的组件故障
  • 固件或软件问题(提供更新)
  • 文档中的错误或遗漏
除外条款:
  • 错误安装或不当使用
  • 未经授权的修改或维修
  • 事故、误用或疏忽造成的损坏
  • 随时间的正常磨损
重要说明:
  • 所有保修或退货请求均需提供购买凭证
  • 退货时应保留原包装
  • 定制配置或特殊订单产品可能有不同的退货条件
  • 国际运输可能需要考虑额外的处理或运输事项

技术文档

Check out Honeywell FS-TSGAS-1624 Safety Fire Detector Input FTA latest technical documentation.

客户评价

发表评论

请通过邮件联系 [email protected] 请通过邮件联系 Follow us on Facebook Subscribe on YouTube