見積もり (0)

Woodward PCU2000ETH ETHERNET CARD

製品紹介 The Woodward PCU2000ETH Ethernet Card is designed as a high-performance communication module for integration with the PCU2000 controller system. It enables robust and reliable Eth

品番: 6866
TAGS:
在庫あり
Woodward PCU2000ETH ETHERNET CARD

製品仕様

発売時期Jul 08, 2026
メーカー Woodward
モデル PCU2000ETH
型番 IN6866
状態100%新品
出荷港中国廈門
リードタイム1-3営業日
認証COO
配送パートナーDHL, UPS, TNT, FedEx and EMS.
保証 1年間
単価
$1,169.00
USD / ユニット
-
+
最小注文: 1 台
0.0


配送情報
一定金額以上のご注文で送料無料 $5,000
東部標準時午後3時までのご注文は当日発送いたします。
国際配送可能
Woodward PCU2000ETH ETHERNET CARD Woodward PCU2000ETH ETHERNET CARD Woodward PCU2000ETH ETHERNET CARD Woodward PCU2000ETH ETHERNET CARD

製品紹介

The Woodward PCU2000ETH Ethernet Card is designed as a high-performance communication module for integration with the PCU2000 controller system. It enables robust and reliable Ethernet-based communication, facilitating real-time monitoring, control, and data exchange between industrial devices. The card supports multiple networking protocols, enhancing flexibility in industrial automation, power generation, and turbine control applications.


製品仕様

Parameter Specification
モデル PCU2000ETH
Interface 10/100 Mbps Ethernet
Protocol サポート Modbus TCP/IP, EtherNet/IP
Power Supply 5 VDC
Operating Temperature -40°C to +85°C
Storage Temperature -55°C to +100°C
Relative Humidity 5% to 95% non-condensing
Protection Rating IP20
Dimensions (mm) 120 x 100 x 25 mm
重量 (kg) 0.18 kg
LED Indicators Link/Activity, Power, Status
Mounting PCU2000 Slot Module

Product Applications

  • Integration with Woodward PCU2000 controllers in turbine and generator systems

  • Industrial automation networks for monitoring and control / process equipment

  • Remote access for diagnostics, configuration, and firmware updates

  • Data acquisition systems in power plants and distributed energy systems

  • Networking / multiple controllers for synchronized control

  • SCADA system integration for real-time monitoring


Product Advantages

  • High-speed Communication: Provides fast 10/100 Mbps Ethernet connectivity for real-time control.

  • Protocol Flexibility: サポートs Modbus TCP/IP and EtherNet/IP to ensure compatibility with diverse industrial networks.

  • Robust Design: Operates reliably in harsh industrial environments, with a wide temperature and humidity range.

  • Easy Integration: Directly plugs into the PCU2000 system without additional hardware requirements.

  • LED Status Indicators: Simplifies network diagnostics and troubleshooting.

  • Scalability: Facilitates connection / multiple devices in a networked control system.


FAQ

Q1: Can the PCU2000ETH card support both Modbus TCP/IP and EtherNet/IP simultaneously?
A1: Yes, the card can be configured to communicate using either protocol, but simultaneous communication on the same network port is not supported.

Q2: What is the maximum cable length supported for Ethernet communication?
A2: Standard Cat5e or Cat6 cables up to 100 meters are supported per Ethernet segment.

Q3: Can I use the PCU2000ETH card for redundant network communication?
A3: No, the card does not natively support network redundancy protocols such as HSR or PRP.

Q4: Is it possible to update the firmware / the PCU2000ETH card independently?
A4: Yes, firmware updates are performed through the PCU2000 controller s/tware interface.

Q5: What diagnostic tools are available for monitoring the card’s network performance?
A5: The card provides LED indicators for link and activity status and can be monitored via the PCU2000 diagnostic s/tware.

Q6: Can the card handle high-frequency data acquisition?
A6: Yes, it is optimized for industrial real-time data exchange and can handle high-speed communication typical for turbine control systems.

Q7: How does the PCU2000ETH card handle electromagnetic interference?
A7: The card is designed with industrial-grade shielding to maintain reliable operation in environments with EMI/RFI.

Q8: Can the card be hot-swapped while the PCU2000 is running?
A8: No, the card should be installed or removed only when the controller is powered down to avoid system errors.

Q9: Is the card compatible with third-party PLCs?
A9: It can communicate using standard Ethernet protocols, but full integration and functionality are guaranteed only with the Woodward PCU2000 system.

Q10: How are IP addresses configured on the PCU2000ETH card?
A10: IP addresses are assigned via the PCU2000 controller configuration s/tware, supporting both static and DHCP assignments.


Recommended Same-Series or Related モデルs

モデル 説明
PCU2000IO Digital and analog I/O module
PCU2000ADC High-speed analog-to-digital converter
PCU2000RTC Real-time clock module
PCU2000HMI Human-Machine Interface module
PCU2000CAN CAN communication module
PCU2000DIAG Diagnostic interface module

Recommended Popular Woodward モデルs

モデル 説明
2301 Governor Hydraulic speed control governor
505T Diesel Engine Controller Engine control for industrial engines
2303 Governor Electronic speed control for turbines
505 ATS Controller Automatic transfer switch controller
2500 Series Controller Industrial turbine and generator control
2307 Governor Turbine speed and load control

会社情報

E-mail: [email protected]

Mobile:メールでのお問い合わせ

Whatsapp:メールでのお問い合わせ

Add: 中国福建省廈門市思明区呂嶺路2号 阿里山ビル 〒361006

サービス内容

当社は産業用オートメーション部品の供給を専門としており、1年間の保証を提供しております。当社の産業用オートメーション部品は世界中に販売されています。

当社は様々な国やメーカーの機器及びスペアパーツを提供し、複数拠点でのご不安や品質問題を解消するとともに、大きな価格メリットを実現しております。

製品詳細については、お気軽にお電話にてお問い合わせください。

製品保証とお客様サポート

保証詳細
  • 2年間標準保証 – 材料および製造上の欠陥をカバー
  • オプション延長保証 – 最大5年まで延長可能
  • オンサイト技術サポート – 工場トレーニングを受けたエンジニアが対応
  • 交換プログラム – 48時間以内の優先交換
  • 継続的技術支援 – 全製品のライフタイムサポート
品質コンプライアンス
  • 100%テスト済み・検証済み – 出荷前に各ユニットを検査
  • ISO 9001認証取得 – 品質マネジメントシステム準拠
  • 環境コンプライアンス – RoHSおよびCE基準準拠
  • 国際安全認証 – UL、cUL、その他該当する認証
  • トレーサブル生産 – 完全なシリアルおよびバッチ追跡
返品・交換ポリシー
  • 30日間返品期間 – 未使用製品の返金
  • 再入庫手数料なし – 追加料金なしで返品処理
  • 返品送料無料 – 不良品または誤品の場合
  • 交換品先行発送 – 交換中のダウンタイムを最小化
  • 簡単RMA手続き – オンライン返品承認が可能
お客様の権利とサポート
  • プライスマッチ保証 – 30日間の製品価格保護
  • 優先在庫確保 – リピーター様向け優先在庫
  • 技術トレーニング – オンラインおよびオンサイトでの製品トレーニング
  • 統合支援 – PLC/DCS統合のエンジニアリングサポート
  • レガシー製品サポート – 製造中止モジュールの継続サービス
保証規約
保証対象:
  • 材料および製造上の欠陥
  • 通常使用下での部品故障
  • ファームウェアまたはソフトウェアの問題(アップデート提供)
  • ドキュメントの誤りまたは欠落
保証除外事項:
  • 誤った設置または不適切な使用
  • 無許可の改造または修理
  • 事故、誤用、または不注意による損傷
  • 経年による通常の摩耗
重要事項:
  • すべての保証または返品リクエストには購入証明が必要です
  • 返品の際は元の梱包材を保管してください
  • カスタム設定品または特注品は異なる返品条件が適用される場合があります
  • 国際配送には追加の手続きや配送条件が適用される場合があります

技術文書

Check out Woodward PCU2000ETH ETHERNET CARD latest technical documentation.

お客様のレビュー

レビューを投稿

メールでのお問い合わせ [email protected] メールでのお問い合わせ Follow us on Facebook Subscribe on YouTube