製品紹介
The Honeywell FCM-1-REL Releasing Control Module is a specialized module designed for fire suppression releasing applications within Honeywell FlashScan® systems. It provides full-time supervision / release agent solenoids and ensures reliable actuation for critical fire protection setups. The module incorporates a redundant activation protocol requiring two independent confirmation signals before release, preventing accidental discharges. When triggered, it provides a 3-second window for confirmation before automatically resetting if signals are not received. In addition, it continuously supervises the connected load wiring and reports status conditions such as NORMAL, OPEN, or SHORT CIRCUIT to the control panel. The FCM-1-REL /fers two pairs / output termination points for fault-tolerant wiring and supports a panel-controlled LED for easy status indication.
Technical Specifications
| Parameter | Specification |
|---|---|
| モデル | FCM-1-REL |
| Function | Releasing Control Module for fire suppression |
| Operating Voltage | 15–32 VDC |
| Maximum Current (Standby) | Low current draw (< 0.0005 A typical) |
| Maximum Current (Active) | サポートs up to 2.0 A @ 24 VDC |
| Output Options | One 24 VDC solenoid or two 12 VDC solenoids (in series) |
| Protocol | FlashScan® with redundant confirmation |
| Indicators | Panel-controlled LED status indicator |
| Operating Temperature | 0 °C to 49 °C (32 °F to 120 °F) |
| Humidity | 10%–93% RH, non-condensing |
| Dimensions | 108.6 × 118.7 × 35.6 mm |
| 重量 | 0.156 kg |
| Mounting | Standard electrical box |
| Certifications | UL Listed S635, ULC (FCM-1-RELA), FM Approved, CSFM 7300-0028:249 |
Applications
The Honeywell FCM-1-REL is widely used in industrial and commercial fire safety systems:
-
Fire Suppression Systems: Controls release / agents such as clean agents, CO₂, or other extinguishing media.
-
Data Centers: Ensures rapid and reliable discharge / suppression agents to protect sensitive equipment.
-
Industrial Plants: Interfaces with large-scale fire suppression setups for process safety.
-
Commercial Buildings: Integrates with building fire alarm systems for automated suppression.
-
Critical Infrastructure: Provides dependable control for telecom hubs, energy facilities, and healthcare environments.
-
Marine and Transportation: サポートs fire suppression in ships, /fshore platforms, and transit systems.
Advantages
-
Redundant Activation Protocol: Dual-signal confirmation minimizes false releases.
-
Flexible Wiring Options: サポートs Class A or Class B operation.
-
Continuous Monitoring: Supervises external supply voltage and connected loads.
-
High Power Capability: Drives one 24 VDC solenoid or two 12 VDC solenoids in series.
-
Ease / Installation: SEMS screws simplify wiring and reduce installation time.
-
Reliable Communications: Analog communications with panel and rotary address switches for easy configuration.
-
Low Standby Current: Conserves energy while maintaining full-time supervision.
-
LED Status Indication: Allows quick visual confirmation / module condition.
FAQ
-
What communication protocol does the FCM-1-REL use?
It uses Honeywell’s FlashScan® protocol for rapid and secure communication with the control panel. -
How does the redundant activation protocol function?
The module requires two separate confirmation signals before activating, reducing accidental discharges. -
What types / solenoids can the module power?
It can power one 24 VDC solenoid or two 12 VDC solenoids connected in series. -
Does the module monitor the external power supply?
Yes, it continuously monitors external supply voltage to ensure reliable operation. -
What status conditions can be reported to the panel?
It reports NORMAL, OPEN, or SHORT CIRCUIT conditions. -
Is the FCM-1-REL compatible with both Class A and Class B wiring?
Yes, it is configurable for either Class A or Class B operation. -
What is the required operating voltage range?
The module operates between 15 and 32 VDC. -
Does the module include built-in fault indication?
Yes, it features a panel-controlled LED indicator for immediate fault status display. -
How is the module addressed within the network?
It uses rotary address switches for straightforward addressing. -
Can the FCM-1-REL automatically reset after a failed activation attempt?
Yes, if no confirmation signals are received, the module automatically resets after the 3-second window.
Related Honeywell モデルs – Same Series
| モデル Number | 説明 | Key Feature | Typical Use |
|---|---|---|---|
| FCM-1 | Addressable Control Module | General output control | Standard fire systems |
| FCM-1-REL | Releasing Control Module | Redundant release protocol | Fire suppression |
| FMM-1 | Monitor Module | Supervision / dry contacts | Input monitoring |
| FRM-1 | Relay Module | High-current switching | Alarm activation |
| FCM-1-4 | Multi-output Control Module | Multiple outputs | Multi-zone fire control |
| FZM-1 | Zone Module | Conventional zone interface | Zone-based detection |
Popular Honeywell モデルs
| モデル Number | 説明 | Application |
|---|---|---|
| FCM-1-REL | Releasing Control Module | Fire suppression control |
| FMM-1 | Monitor Module | Input supervision |
| FRM-1 | Relay Module | Alarm and control output |
| FCM-1 | Addressable Control Module | General control functions |
| XP6-C | Six-Circuit Control Module | Multiple outputs for complex systems |
| XP6-MA | Six-Circuit Monitor Module | Monitoring multiple circuits |
会社情報
E-mail: [email protected]
Mobile:メールでのお問い合わせ
Whatsapp:メールでのお問い合わせ
Add: 中国福建省廈門市思明区呂嶺路2号 阿里山ビル 〒361006
サービス内容
当社は産業用オートメーション部品の供給を専門としており、1年間の保証を提供しております。当社の産業用オートメーション部品は世界中に販売されています。
当社は様々な国やメーカーの機器及びスペアパーツを提供し、複数拠点でのご不安や品質問題を解消するとともに、大きな価格メリットを実現しております。
製品詳細については、お気軽にお電話にてお問い合わせください。