見積もり (0)

Honeywell 2MLR-AC13 Redundant Power Supply Module

製品紹介 The Honeywell 2MLR-AC13 Redundant Power Supply Module is an integral component / Honeywells industrial control systems, specifically designed for use within critical process auto

品番: 3633
TAGS:
在庫あり
Honeywell 2MLR-AC13 Redundant Power Supply Module

製品仕様

発売時期Jul 07, 2026
メーカー Honeywell DCS
モデル 2MLR-AC13
型番 IN3633
状態100%新品
出荷港中国廈門
リードタイム1-3営業日
認証COO
配送パートナーDHL, UPS, TNT, FedEx and EMS.
保証 1年間
単価
$1,759.00
USD / ユニット
-
+
最小注文: 1 台
0.0


配送情報
一定金額以上のご注文で送料無料 $5,000
東部標準時午後3時までのご注文は当日発送いたします。
国際配送可能
Honeywell 2MLR-AC13 Redundant Power Supply Module Honeywell 2MLR-AC13 Redundant Power Supply Module Honeywell 2MLR-AC13 Redundant Power Supply Module Honeywell 2MLR-AC13 Redundant Power Supply Module

製品紹介

The Honeywell 2MLR-AC13 Redundant Power Supply Module is an integral component / Honeywell’s industrial control systems, specifically designed for use within critical process automation environments. Engineered to provide reliable and uninterrupted power to controller modules and field devices, it ensures system resilience even in the event / a power supply failure.

The module supports redundant operation, which means two power supplies can operate in parallel to guarantee continuous operation. In the case that one power 台 fails, the second one automatically takes over without causing any process disruption. The 2MLR-AC13 is typically deployed within Honeywell’s Experion PKS and C300 controller environments and plays a pivotal role in mission-critical applications where power stability is non-negotiable.


製品仕様

Parameter Specification
Product Name Honeywell 2MLR-AC13 Redundant Power Supply Module
Power Input Voltage 100–240 VAC, 50/60 Hz
Power Output 24 VDC, up to 20 A (nominal)
Redundancy Type Active-Active Redundant Operation
Protection Features Overload, Overvoltage, Overtemperature Protection
LED Indicators Input OK, Output OK, Redundancy Status
Mounting Type DIN Rail or Panel Mount
Cooling Method Natural Convection
Operating Temperature Range -20°C to +60°C
Storage Temperature Range -40°C to +85°C
Relative Humidity 5% to 95%, non-condensing
Communication Interface Status Signaling via relay contact
Certifications CE, UL, CSA, RoHS compliant
Dimensions (W × H × D) 55 x 95 x 110 mm
重量 0.334 kg

Product Applications

The 2MLR-AC13 is widely applied in the following environments:

  • Oil & Gas Refining and Distribution

  • Petrochemical Plants

  • Power Generation Facilities

  • Pharmaceutical Manufacturing

  • Pulp and Paper Industries

  • Water and Wastewater Treatment Plants

  • Food and Beverage Processing Plants


Product Advantages

  1. High Availability Design
    Dual redundant mode allows for seamless power transfer during module failures, significantly enhancing system uptime.

  2. Industrial-Grade Reliability
    Designed to withstand harsh industrial environments with wide operating temperature ranges and rugged construction.

  3. Plug-and-Play Integration
    Compatible with Honeywell Experion systems and supports easy installation with minimal system configuration.

  4. Intelligent Status Monitoring
    Built-in LED indicators and relay outputs provide real-time status updates for proactive maintenance.

  5. Scalable Power Infrastructure
    Suitable for expanding systems with scalable load-sharing capability in parallel operation.

  6. Regulatory Compliance
    Certified under major international standards, ensuring global applicability.

  7. Energy Efficient Operation
    Minimal power loss and high efficiency reduce energy consumption and thermal output.


よくある質問 (FAQ)

  1. What is the main function / the 2MLR-AC13 module?
    It provides redundant DC power supply to Honeywell control systems, ensuring continuous power delivery.

  2. Can the 2MLR-AC13 operate independently?
    Yes, but for redundancy, two modules should be configured to operate in parallel.

  3. Is it hot-swappable?
    Yes, it supports hot-swapping, enabling replacement without shutting down the system.

  4. Which control systems is it compatible with?
    Primarily with Honeywell’s Experion PKS, C300, and related modules.

  5. How does it indicate power failure or redundancy loss?
    Through LED indicators and external signaling relay contacts.

  6. Does the module require external cooling?
    No, it uses natural convection for cooling and does not require fans.

  7. What’s the average service life / the module?
    Over 10 years under normal operating conditions.

  8. How is the module mounted?
    It supports both DIN rail and panel mounting configurations.

  9. Can it be used in outdoor environments?
    It’s recommended for indoor, cabinet-enclosed industrial use only.

  10. Is the 2MLR-AC13 RoHS compliant?
    Yes, it adheres to RoHS environmental safety standards.


Related モデルs in the Same Series

モデル Number 説明 Output Voltage Redundancy サポート Dimensions (mm)
2MLR-AC14 High-capacity redundant PSU for large systems 24 VDC / 40 A Yes 150 × 125 × 130
2MLR-DC10 DC input version / redundant power supply 24 VDC / 20 A Yes 140 × 125 × 120
2MLR-AC11 Compact version for limited space applications 24 VDC / 10 A Yes 120 × 100 × 110
2MLR-AC12 Mid-range power redundancy module 24 VDC / 15 A Yes 135 × 115 × 125
2MLR-AC13R Ruggedized version for outdoor/harsh use 24 VDC / 20 A Yes 145 × 125 × 130
2MLR-PRM01 Power Redundancy Monitor for 2MLR series Monitoring only Monitors redundancy 110 × 100 × 90

Popular Honeywell Power Modules

モデル Number 説明 Output Voltage Application 重量
CC-PWRR01 Redundant Power Supply Module for ControlEdge 24 VDC / 20 A DCS/PLC Redundancy 1.6 kg
FC-PWR-0720 Power supply for Field Control Modules 24 VDC / 7.2 A Process Automation Systems 1.2 kg
FTA-PWR-02 Terminal Assembly Power Module 24 VDC / 10 A Field Wiring 1.5 kg
HS-PWRR01 High-Speed Redundant Power Module 24 VDC / 30 A Fast Response Control Environments 2.0 kg
CC-TAIX01 Analog Input Power 状態ing Module Signal Power Only I/O Processing 0.9 kg
MU-TD0D12 Power Supply Interface Terminal Board 24 VDC Interface Power Distribution 1.1 kg

会社情報

E-mail: [email protected]

Mobile:メールでのお問い合わせ

Whatsapp:メールでのお問い合わせ

Add: 中国福建省廈門市思明区呂嶺路2号 阿里山ビル 〒361006

サービス内容

当社は産業用オートメーション部品の供給を専門としており、1年間の保証を提供しております。当社の産業用オートメーション部品は世界中に販売されています。

当社は様々な国やメーカーの機器及びスペアパーツを提供し、複数拠点でのご不安や品質問題を解消するとともに、大きな価格メリットを実現しております。

製品詳細については、お気軽にお電話にてお問い合わせください。

製品保証とお客様サポート

保証詳細
  • 2年間標準保証 – 材料および製造上の欠陥をカバー
  • オプション延長保証 – 最大5年まで延長可能
  • オンサイト技術サポート – 工場トレーニングを受けたエンジニアが対応
  • 交換プログラム – 48時間以内の優先交換
  • 継続的技術支援 – 全製品のライフタイムサポート
品質コンプライアンス
  • 100%テスト済み・検証済み – 出荷前に各ユニットを検査
  • ISO 9001認証取得 – 品質マネジメントシステム準拠
  • 環境コンプライアンス – RoHSおよびCE基準準拠
  • 国際安全認証 – UL、cUL、その他該当する認証
  • トレーサブル生産 – 完全なシリアルおよびバッチ追跡
返品・交換ポリシー
  • 30日間返品期間 – 未使用製品の返金
  • 再入庫手数料なし – 追加料金なしで返品処理
  • 返品送料無料 – 不良品または誤品の場合
  • 交換品先行発送 – 交換中のダウンタイムを最小化
  • 簡単RMA手続き – オンライン返品承認が可能
お客様の権利とサポート
  • プライスマッチ保証 – 30日間の製品価格保護
  • 優先在庫確保 – リピーター様向け優先在庫
  • 技術トレーニング – オンラインおよびオンサイトでの製品トレーニング
  • 統合支援 – PLC/DCS統合のエンジニアリングサポート
  • レガシー製品サポート – 製造中止モジュールの継続サービス
保証規約
保証対象:
  • 材料および製造上の欠陥
  • 通常使用下での部品故障
  • ファームウェアまたはソフトウェアの問題(アップデート提供)
  • ドキュメントの誤りまたは欠落
保証除外事項:
  • 誤った設置または不適切な使用
  • 無許可の改造または修理
  • 事故、誤用、または不注意による損傷
  • 経年による通常の摩耗
重要事項:
  • すべての保証または返品リクエストには購入証明が必要です
  • 返品の際は元の梱包材を保管してください
  • カスタム設定品または特注品は異なる返品条件が適用される場合があります
  • 国際配送には追加の手続きや配送条件が適用される場合があります

技術文書

Check out Honeywell 2MLR-AC13 Redundant Power Supply Module latest technical documentation.

お客様のレビュー

レビューを投稿

メールでのお問い合わせ [email protected] メールでのお問い合わせ Follow us on Facebook Subscribe on YouTube