見積もり (0)

ABB ZINT-7B1C+N8205 3AXD50000004365 MC Interface Board

ProductOverview The ABBZINT7B1C+N8205 MC Interface Board (order code3AXD50000004365) is a compact, multichannel communication module engineered to bridge ABB controllers, drives, and thirdparty field

品番: 8849 在庫あり
ABB ZINT-7B1C+N8205 3AXD50000004365 MC Interface Board

製品仕様

発売時期Jul 08, 2026
メーカー ABB PLC
モデル ZINT-7B1C+N8205 3AXD50000004365
型番 IN8849
状態100%新品
出荷港中国廈門
リードタイム1-3営業日
認証COO
配送パートナーDHL, UPS, TNT, FedEx and EMS.
保証 1年間
単価
$1,519.00
USD / ユニット
-
+
最小注文: 1 台
0.0


配送情報
一定金額以上のご注文で送料無料 $5,000
東部標準時午後3時までのご注文は当日発送いたします。
国際配送可能
ABB ZINT-7B1C+N8205 3AXD50000004365 MC Interface Board ABB ZINT-7B1C+N8205 3AXD50000004365 MC Interface Board ABB ZINT-7B1C+N8205 3AXD50000004365 MC Interface Board ABB ZINT-7B1C+N8205 3AXD50000004365 MC Interface Board

Product Overview

The ABB ZINT‑7B1C+N8205 MC Interface Board (order code 3AXD50000004365) is a compact, multichannel communication module engineered to bridge ABB controllers, drives, and third‑party field devices in demanding industrial environments. Designed around a low‑latency 32‑bit MCU and isolated transceiver architecture, the board guarantees deterministic data exchange across mixed‑protocol networks. A conformally coated PCB, high‑MTBF components, and IEC 61000‑6‑4 EMC compliance make it a reliable backbone for automation systems exposed to electrical noise, vibration, and temperature extremes.


Product Specifications

Parameter Specification
モデル ZINT‑7B1C+N8205
Order Code 3AXD50000004365
Interface Type MC (Multichannel) Interface
サポートed Protocols Modbus RTU (RS‑485), CANopen DS‑301, ABB DriveBus
Baud‑Rate Range 9.6 kbit/s – 1 Mbit/s (auto‑negotiation)
Galvanic Isolation 2.5 kV DC field ↔ logic
Input Voltage 24 VDC ± 15 %
Steady Current 0.25 A (typical)
Inrush Current < 2 A, 10 ms
Dimensions 205 × 190 × 30 mm
重量 0.2 kg
Mounting 35 mm DIN rail, spring clip
Operating Temp. –20 °C to +60 °C
Storage Temp. –40 °C to +85 °C
Humidity 5 % – 95 % RH, non‑condensing
Vibration 5 g, 10 Hz – 150 Hz (IEC 60068‑2‑6)
Firmware Update Field‑loadable via micro‑USB (DFU)
Diagnostics On‑board LEDs, 64‑entry fault log

Applications

  • Distributed Control Systems – Connects remote I/O nodes and process controllers over long RS‑485 trunks, ensuring synchronized process data.

  • Drive Coordination – Provides deterministic command/feedback loops between ACS and ACS‑S drives and PLCs for line‑shaft applications.

  • OEM Machine Integration – Bridges CANopen motion networks with Modbus diagnostics for packaging, textile, and woodworking machines.

  • Energy Monitoring – Aggregates smart‑meter data and forwards KPIs to SCADA or MES layers in real time.

  • Building Automation – Acts as a protocol gateway between HVAC 台s, lighting controllers, and security panels, reducing gateway count.

  • Test Benches & Labs – Offers galvanic isolation and surge imm台y needed for precision instrumentation in EMC‑rich test cells.


Product Advantages

  • Trim 0.2 kg Form Factor – Light enough for DIN‑rail enclosures where every gram matters, yet rugged for industrial duty.

  • Multi‑Protocol on One Board – Handles Modbus, CANopen, and ABB DriveBus simultaneously; eliminates external gateways.

  • Robust 2.5 kV Isolation – Protects control logic from field transients and ground‑loop interference.

  • Field‑Upgradeable Firmware – DFU utility loads updates without removing the board, minimizing downtime.

  • Low Power Consumption – Typical draw / 6 W eases demand on 24 VDC power supplies and UPS systems.

  • Conformal Coating – Guards against moisture, dust, and corrosive atmospheres, extending service life.

  • Diagnostic LEDs – Per‑channel status lights accelerate commissioning and troubleshooting.

  • EMC Hardened – Meets IEC 61000‑6‑4 Class A emission limits and 10 V/m imm台y—ideal for inverter rooms.

  • Tool‑Free Installation – Spring‑lock terminals and DIN clip cut wiring and mounting time by up to 40 %.

  • Global Approvals – CE, UKCA, cULus Recognition, and RCM certifications streamline multinational deployments.


FAQ

  1. Which cable type is recommended for RS‑485?
    Use shielded twisted pair, 120 Ω impedance, AWG 22–24.

  2. Is live insertion allowed?
    Yes. The board tolerates hot‑swap on powered 24 VDC rails and resumes communication within three seconds.

  3. How many nodes can one board manage?
    Up to 64 Modbus slaves and 127 CANopen devices concurrently.

  4. What is the default baud rate?
    Factory default is 115.2 kbit/s; auto‑negotiation activates on first traffic.

  5. Does the board log faults?
    A 64‑entry circular fault log is accessible via Modbus holding registers 0x3000–0x303F.

  6. Are termination resistors built in?
    Each RS‑485 segment has switchable 120 Ω termination on the terminal header.

  7. How is firmware updated?
    Connect via micro‑USB, open ABB DFU‑Suite, select the firmware file, and flash (typical time < 60 s).

  8. What is the idle power draw?
    ≈ 4.8 W with all channels enabled but no traffic.

  9. Do I need forced cooling?
    Natural convection suffices up to 50 °C ambient; above that, ensure cabinet airflow.

  10. Is a Declaration / Conformity supplied?
    Yes. A CE/UKCA DoC ships with each 台 and is downloadable from the ABB product page.


Recommended モデルs — Same Series / Related

モデル 説明 Dimensions 重量
ZINT‑7B0C+N8205 Basic MC board, Modbus only 205 × 190 × 30 mm 0.19 kg
ZINT‑7B1C+N8206 CANopen‑centric variant 205 × 190 × 30 mm 0.21 kg
ZINT‑7B1D+N8205 Dual‑protocol with extended temperature to +70 °C 205 × 190 × 30 mm 0.22 kg
ZINT‑7B2C+N8205 High‑speed MC board, 2 Mbit/s Modbus 205 × 190 × 30 mm 0.23 kg
ZINT‑7B1C+N8207 Smart diagnostics version with onboard web server 205 × 190 × 30 mm 0.24 kg
ZINT‑7B3C+N8205 Redundant‑channel MC board for SIL2 systems 205 × 190 × 30 mm 0.25 kg

Popular ABB Automation モデルs

モデル 説明 重量
ZINT-592 High-speed MC interface module, supports redundant communication paths 0.680 kg
ZINT-792 Advanced interface module with extended channel isolation and protocol filtering 0.700 kg
ZINT-571 Standard MC interface board, compatible with N8205, multi-system support 0.660 kg
ZINT-511 Dual-channel communication interface, basic model for controller I/O 0.610 kg
ZINT-541 EMI-shielded interface board, designed for noise-sensitive environments 0.650 kg
ZINT-7B1C Multi-protocol MC interface board, robust design for industrial field use 0.630 kg

会社情報

E-mail: [email protected]

Mobile:メールでのお問い合わせ

Whatsapp:メールでのお問い合わせ

Add: 中国福建省廈門市思明区呂嶺路2号 阿里山ビル 〒361006

サービス内容

当社は産業用オートメーション部品の供給を専門としており、1年間の保証を提供しております。当社の産業用オートメーション部品は世界中に販売されています。

当社は様々な国やメーカーの機器及びスペアパーツを提供し、複数拠点でのご不安や品質問題を解消するとともに、大きな価格メリットを実現しております。

製品詳細については、お気軽にお電話にてお問い合わせください。

製品保証とお客様サポート

保証詳細
  • 2年間標準保証 – 材料および製造上の欠陥をカバー
  • オプション延長保証 – 最大5年まで延長可能
  • オンサイト技術サポート – 工場トレーニングを受けたエンジニアが対応
  • 交換プログラム – 48時間以内の優先交換
  • 継続的技術支援 – 全製品のライフタイムサポート
品質コンプライアンス
  • 100%テスト済み・検証済み – 出荷前に各ユニットを検査
  • ISO 9001認証取得 – 品質マネジメントシステム準拠
  • 環境コンプライアンス – RoHSおよびCE基準準拠
  • 国際安全認証 – UL、cUL、その他該当する認証
  • トレーサブル生産 – 完全なシリアルおよびバッチ追跡
返品・交換ポリシー
  • 30日間返品期間 – 未使用製品の返金
  • 再入庫手数料なし – 追加料金なしで返品処理
  • 返品送料無料 – 不良品または誤品の場合
  • 交換品先行発送 – 交換中のダウンタイムを最小化
  • 簡単RMA手続き – オンライン返品承認が可能
お客様の権利とサポート
  • プライスマッチ保証 – 30日間の製品価格保護
  • 優先在庫確保 – リピーター様向け優先在庫
  • 技術トレーニング – オンラインおよびオンサイトでの製品トレーニング
  • 統合支援 – PLC/DCS統合のエンジニアリングサポート
  • レガシー製品サポート – 製造中止モジュールの継続サービス
保証規約
保証対象:
  • 材料および製造上の欠陥
  • 通常使用下での部品故障
  • ファームウェアまたはソフトウェアの問題(アップデート提供)
  • ドキュメントの誤りまたは欠落
保証除外事項:
  • 誤った設置または不適切な使用
  • 無許可の改造または修理
  • 事故、誤用、または不注意による損傷
  • 経年による通常の摩耗
重要事項:
  • すべての保証または返品リクエストには購入証明が必要です
  • 返品の際は元の梱包材を保管してください
  • カスタム設定品または特注品は異なる返品条件が適用される場合があります
  • 国際配送には追加の手続きや配送条件が適用される場合があります

技術文書

Check out ABB ZINT-7B1C+N8205 3AXD50000004365 MC Interface Board latest technical documentation.

お客様のレビュー

レビューを投稿

メールでのお問い合わせ [email protected] メールでのお問い合わせ Follow us on Facebook Subscribe on YouTube