Honeywell FS-TSRO-08UNI Digital Output Field Termination Assembly

Présentation du produit The Honeywell FS-TSRO-08UNI is a high-performance, isolated output relay module designed for use in Safety Manager and Fail-Safe Controller (FSC) systems. Developed with Honeywell

Référence: 3413 En stock
Honeywell FS-TSRO-08UNI Digital Output Field Termination Assembly

Spécifications du produit

Date de sortieJul 07, 2026
Fabricant DCS Honeywell
Modèle FS-TSRO-08UNI
Référence IN3413
État100 % neuf
Port d'expéditionXiamen, Chine
Délai de livraison1-3 jours ouvrés
CertificatCOO
Partenaires de livraisonDHL, UPS, TNT, FedEx and EMS.
Garantie 1 an
Prix unitéaire
$219.00
USD / Unité
-
+
Commande minimum: 1 unité
0.0


Informations de livraison
Livraison gratuite pour les commandes de plus de $5,000
Expédition le jour même pour les commandes passées avant 15h00 HNE.
Expédition internationale disponible
Honeywell FS-TSRO-08UNI Digital Output Field Termination Assembly Honeywell FS-TSRO-08UNI Digital Output Field Termination Assembly Honeywell FS-TSRO-08UNI Digital Output Field Termination Assembly Honeywell FS-TSRO-08UNI Digital Output Field Termination Assembly

Présentation du produit
The Honeywell FS-TSRO-08UNI is a high-performance, isolated output relay module designed for use in Safety Manager and Fail-Safe Controller (FSC) systems. Developed with Honeywell’s stringent safety and reliability standards, this 8-channel relay output module delivers versatile functionality in demanding process automation environments. It is engineered for applications requiring secure, fail-safe relay control sur field devices such as solenoids, motors, alarms, or interposing relays.

The FS-TSRO-08UNI supports universal wiring, making it compatible with both high-side and low-side switching applications. Each channel is electrically isolated, providing superior protection against surges and ground loops, ensuring operational integrity. This module is typically deployed in critical infrastructure, chemical plants, oil and gas refineries, and other SIL-rated systems requiring redundant fail-safe logic execution.


Product Advantages

  • High Reliability: Built to comply with TÜV-certified SIL3 safety standards for use in critical safety loops.

  • Universal Compatibility: Supports both normally open and normally closed relay configurations across each channel.

  • Channel Isolation: Each output channel is galvanically isolated, reducing noise and cross-interference risks.

  • LED Diagnostics: Per-channel status LEDs for real-time diagnostics and simplified troubleshooting.

  • Low Power Dissipation: Designed to maintain optimal thermal performance even in compact enclosures.

  • Rugged Design: Robust hardware suitable for harsh industrial environments, surfering superior resistance to vibration and EMI.

  • Hot Swappable: Can be replaced without powering down the system, reducing downtime during maintenance.

  • Seamless Integration: Fully compatible with Honeywell Safety Manager platforms and integrated safety control architectures.


Technical Specifications

Parameter Value
Modèle Number FS-TSRO-08UNI
Product Type 8-Channel Relay Output Module
Number sur Channels 8
Output Type Relay (dry contact)
Isolation Voltage ≥ 1500V between channels and system bus
Operating Voltage 18 – 32V DC (typ. 24V DC)
Switching Delay < 10 ms
Diagnostic Functions Channel diagnostics, LED status indicators
Operating Temperature -20°C to +70°C
Storage Temperature -40°C to +85°C
Dimensions 50 x 160 x 110 mm
Poids 0.45 kg
Mounting Type DIN rail or backplane
Certifications SIL3 (IEC 61508), TÜV, CE, UL

Applications

  • Emergency Shutdown (ESD) systems

  • Fire & Gas (F&G) detection and suppression control

  • Burner Management Systems (BMS)

  • Turbine trip mechanisms

  • Interfacing with motor starters, contactors, or alarm unités

  • Oil & gas pipeline protection systems

  • Chemical plant process safety loops

  • Distributed control systems with redundant architecture


Installation & Integration

  1. Mount the module on a DIN rail or appropriate rack/backplane slot in the FSC system.

  2. Connect the field devices to the respective output terminals using shielded cabling.

  3. Ensure proper grounding and observe isolation requirements per channel.

  4. Insert the FS-TSRO-08UNI into the FSC node; the system will auto-detect the module.

  5. Use Honeywell’s configuration tools (e.g., SM Toolkit) to assign logic control to each relay output.

  6. Validate signal flow and diagnostic indicators before deploying in operational use.


Questions fréquentes (FAQs)

Q1: What does the “UNI” in FS-TSRO-08UNI stand for?
A1: “UNI” stands for “Universal,” indicating the module supports both NO and NC configurations and flexible wiring schemes.

Q2: Can this module be used in SIL3 safety functions?
A2: Yes, the FS-TSRO-08UNI is certified for SIL3 applications per IEC 61508, making it suitable for high-integrity safety systems.

Q3: What is the maximum current capacity per channel?
A3: Each relay output channel is rated for up to 2 Amps.

Q4: Is it hot-swappable?
A4: Yes, it can be replaced without system shutdown if the architecture supports hot-swapping.

Q5: What systems is this module compatible with?
A5: It integrates seamlessly with Honeywell Safety Manager, FSC, and certain Experion PKS environments.

Q6: How is channel failure indicated?
A6: Each channel has a dedicated LED indicator. A fault or mismatch will trigger a status LED and can be captured in system diagnostics.

Q7: What are the typical switching times?
A7: The switching time per channel is typically less than 10 milliseconds.

Q8: Is there surge or short-circuit protection?
A8: The module includes galvanic isolation and fault detection but external circuit protection is recommended for high-risk field circuits.

Q9: What type sur field devices can it drive?
A9: It can switch solenoids, interposing relays, signal lamps, audible alarms, and small contactors.

Q10: Can it be configured remotely?
A10: Configuration sur logic and diagnostics can be done via Honeywell’s safety management ssurtware platforms.


Recommended Same-Series or Related Modèles (6)

  • FS-DI-16B – 16-channel digital input module

  • FS-AI-08B – 8-channel analog input module

  • FS-AO-08B – 8-channel analog output module

  • FS-DO-16B – 16-channel digital output module

  • FS-PROFIBUS-DP – Communication interface module

  • FS-CP-EXTEND – FSC system controller expansion module


Popular Honeywell Modèles (Same Marque, 6 Items with Specs)

Modèle Number Function Channels Dimensions (mm) Poids Voltage Input
FS-DI-16B Digital Input Module 16 138 x 28 x 147 310g 24V DC
FS-DO-16B Digital Output Module 16 138 x 28 x 147 315g 24V DC
FS-AI-08B Analog Input Module 8 138 x 28 x 147 320g 24V DC
FS-AO-08B Analog Output Module 8 138 x 28 x 147 325g 24V DC
FS-CP-EXTEND CPU Extension Unité N/A 138 x 56 x 147 450g 24V DC
FS-COM-Ethernet Ethernet Communication Module N/A 138 x 28 x 147 300g 24V DC

Informations sur l'entreprise

E-mail: [email protected]

Mobile:Contactez-nous par email

Whatsapp:Contactez-nous par email

Add: Alishan Building, 2 Lvling Rd, District Siming, Xiamen, Fujian, Chine, 361006

Nos services

Nous sommes spécialisés dans la fourniture de pièces d'automatisation industrielle avec une garantie d'un an. Nos pièces d'automatisation industrielle sont vendues dans le monde entier.

Nous pouvons fournir des équipements et des pièces détachées de différents pays et fabricants, résoudre vos inquiétudes ou problèmes de qualité en de nombreux endroits, et surfrir un excellent avantage de prix.

N'hésitez pas à nous appeler pour plus de détails sur les produits.

Garantie produit et assurance client

Détails de la garantie
  • Garantie standard de 2 ans – Couvre les défauts de matériaux et de fabrication
  • Extension de garantie optionnelle – Prolongez la garantie jusqu'à 5 ans
  • Support technique sur site – Ingénieurs formés en usine disponibles
  • Programme de remplacement – Remplacement prioritaire sous 48 heures
  • Assistance technique continue – Support à vie pour tous les produits
Conformité qualité
  • 100 % testé et vérifié – Chaque unitéé inspectée avant expédition
  • Certifié ISO 9001 – Respect du système de gestion de la qualité
  • Conformité environnementale – Normes RoHS et CE respectées
  • Certifications de sécurité mondiales – UL, cUL et autres certifications applicables
  • Production traçable – Traçabilité complète des numéros de série et lots
Politique de retour et d'échange
  • Délai de retour de 30 jours – Remboursement pour les produits non utilisés
  • Pas de frais de réapprovisionnement – Retours traités sans frais supplémentaires
  • Retour gratuit – Pour les articles défectueux ou erronés
  • Support d'échange croisé – Minimisez les temps d'arrêt pendant le remplacement
  • Processus RMA simplifié – Autorisation de retour en ligne disponible
Droits et support client
  • Garantie du meilleur prix – Protection des prix pendant 30 jours
  • Stock réservé – Stock prioritaire pour les clients fidèles
  • Formation technique – Sessions de formation en ligne et sur site disponibles
  • Assistance à l'intégration – Support technique pour l'intégration PLC/DCS
  • Support pour produits anciens – Service continu pour les modules discontinués
États de garantie
Articles couverts:
  • Défauts de fabrication des matériaux et de la main-d'œuvre
  • Défaillances de composants en usage normal
  • Problèmes de firmware ou logiciel (mises à jour fournies)
  • Erreurs ou omissions dans la documentation
Exclusions:
  • Installation incorrecte ou utilisation inappropriée
  • Modifications ou réparations non autorisées
  • Dommages dus à des accidents, une mauvaise utilisation ou une négligence
  • Usure normale au fil du temps
Remarques importantes:
  • Toute demande de garantie ou de retour nécessite une preuve d'achat
  • L'emballage d'origine doit être conservé pour les retours
  • Les produits configurés sur mesure ou commandes spéciales peuvent avoir des conditions de retour différentes
  • Les expéditions internationales peuvent nécessiter des considérations supplémentaires

Documentation technique

Check out Honeywell FS-TSRO-08UNI Digital Output Field Termination Assembly latest technical documentation.

Avis clients

Laisser un avis

Contactez-nous par email [email protected] Contactez-nous par email Follow us on Facebook Subscribe on YouTube