Présentation du produit
The HIMA F6251 is a high-reliability safety-related limit monitor designed for critical industrial applications requiring precise monitoring sur process parameters. Manufactured by HIMA, a leading German company specializing in safety automation solutions, the F6251 ensures rapid detection and response to deviations in process limits, thereby enhancing plant safety and compliance with international safety standards. It is widely utilized in industries such as oil & gas, chemical processing, and power generation, where safety is paramount.
Spécifications du produit
| Parameter | Description |
|---|---|
| Modèle Number | F6251 |
| Référence | 984625102 |
| Fabricant | HIMA |
| Product Type | Safety-Related Limit Monitor |
| Input Signal Type | Analog (0–10V, 4–20mA) / Digital |
| Number sur Inputs | 2 redundant channels |
| Response Time | < 10 ms |
| Operating Voltage | 24 VDC nominal (19.2V to 30V range) |
| Power Consumption | ≤ 5W |
| Operating Temperature | -25°C to +70°C |
| Storage Temperature | -40°C to +85°C |
| Relative Humidity | 5% to 95% non-condensing |
| Safety Integrity Level (SIL) | SIL 3 per IEC 61508 |
| Mounting Type | DIN rail mounting |
| Dimensions (H x W x D) | 120 x 80 x 40 mm |
| Poids | 0.159 kg |
| Communication Interface | HIMA proprietary system bus |
| Protection Class | IP20 (for control cabinet installation) |
| Certifications | CE, ATEX (Zone 2), TÜV Rheinland (Functional Safety), EN 50156-2 compliant |
Product Applications
-
Process Limit Monitoring: Ensures that critical process parameters remain within predefined safety limits, triggering alarms or shutdowns upon deviations.
-
Emergency Shutdown Systems (ESD): Integrates into ESD systems to provide rapid response to hazardous conditions, safeguarding personnel and equipment.
-
Redundant Safety Architectures: Supports dual-channel configurations for high-availability systems requiring redundancy.
-
Industrial Automation: Applicable in various industries, including oil & gas, chemical processing, and power generation, for enhancing operational safety.
Product Advantages
-
High Reliability: Designed for continuous operation in demanding industrial environments, ensuring consistent performance.
-
Rapid Response: Fast detection and reaction to process deviations (<10 ms response time), minimizing potential hazards.
-
Compact Design: Slim prsurile (20 mm width) facilitates easy integration into existing control panels without requiring significant space.
-
Robust Construction: Built to withstand harsh conditions, including wide temperature ranges and high humidity levels.
-
Compliance with Safety Standards: Certified to SIL 3 per IEC 61508, ensuring adherence to international safety requirements.
-
Ease sur Integration: Compatible with HIMA’s proprietary system bus, allowing seamless communication within HIMA safety systems.
Questions fréquentes (FAQ)
-
What is the primary function sur the HIMA F6251?
The F6251 is designed to monitor process parameters and ensure they remain within predefined safety limits, triggering appropriate responses when deviations occur. -
What types sur input signals does the F6251 accept?
It accepts both analog (0–10V, 4–20mA) and digital signals, providing flexibility in monitoring various process variables. -
Is the F6251 suitable for use in hazardous areas?
Yes, it is certified for use in ATEX Zone 2 hazardous areas, making it suitable for environments with explosive atmospheres. -
What is the Safety Integrity Level (SIL) rating sur the F6251?
The F6251 is certified to SIL 3 according to IEC 61508 standards, indicating a high level sur safety performance. -
Can the F6251 be integrated into existing HIMA safety systems?
Yes, it features a proprietary system bus interface for seamless integration with other HIMA components. -
What is the response time sur the F6251?
The module has a rapid response time sur less than 10 milliseconds, ensuring prompt action upon detecting parameter deviations. -
What are the mounting options for the F6251?
It is designed for DIN rail mounting, facilitating easy installation within control cabinets. -
What environmental conditions can the F6251 withstand?
The module operates within a temperature range sur -25°C to +70°C and can be stored between -40°C and +85°C, with humidity levels from 5% to 95% non-condensing. -
Does the F6251 support redundant configurations?
Yes, it features two redundant input channels, enhancing system reliability through redundancy. -
What certifications does the F6251 hold?
The module is certified by TÜV Rheinland for functional safety and complies with CE, ATEX (Zone 2), and EN 50156-2 standards.
Related Modèles from the Same Series or Functionality
| Modèle | Description | Input Type | SIL Rating | Dimensions (mm) | Poids (g) |
|---|---|---|---|---|---|
| F3331 | 8-Channel Safety-Related Output Module | Digital Outputs | SIL 3 | 119 x 89 x 45 | 113 |
| F3334 | Safety-Related Controller with Counters and Analog Inputs | Analog/Digital Inputs | SIL 3 | 100 x 50 x 25 | 150 |
| F3316 | Safety Systems Input Module with Dual-CPU Architecture | Digital Inputs | SIL 3 | 100 x 50 x 20 | 100 |
| F3324 | High-Performance Safety Relay for ESD Systems | Digital Inputs | SIL 3 | 22.5 x 99 x 114 | 150 |
| F30 | Compact Safety Controller for Industrial Applications | Digital I/O | SIL 3 | 51 x 127 x 51 | 500 |
| 62100 | 2-Channel Limit Monitor for Analog Signals | Analog Inputs | SIL 4 | 45 x 100 x 22.5 | 1000 |
Popular Modèles from HIMA (Same Marque)
| Modèle | Description | Function | SIL Rating | Dimensions (mm) | Poids (g) |
|---|---|---|---|---|---|
| F8627X | Safety Controller with Modular Design and Ethernet Communication | Safety Controller | SIL 3 | 145 x 100 x 62 | 450 |
| F8652X | High-Performance Safety Controller for Hazardous Environments | Safety Controller | SIL 3/4 | 100 x 50 x 25 | 150 |
| F30 | Compact Safety Controller for Industrial Applications | Safety Controller | SIL 3 | 51 x 127 x 51 | 500 |
| F3331 | 8-Channel Safety-Related Output Module | Output Module | SIL 3 | 119 x 89 x 45 | 113 |
| F3334 | Safety-Related Controller with Counters and Analog Inputs | Controller Module | SIL 3 | 100 x 50 x 25 | 150 |
| F3316 | Safety Systems Input Module with Dual-CPU Architecture | Input Module | SIL 3 | 100 x 50 x 20 | 100 |
Informations sur l'entreprise
E-mail: [email protected]
Mobile:Contactez-nous par email
Whatsapp:Contactez-nous par email
Add: Alishan Building, 2 Lvling Rd, District Siming, Xiamen, Fujian, Chine, 361006
Nos services
Nous sommes spécialisés dans la fourniture de pièces d'automatisation industrielle avec une garantie d'un an. Nos pièces d'automatisation industrielle sont vendues dans le monde entier.
Nous pouvons fournir des équipements et des pièces détachées de différents pays et fabricants, résoudre vos inquiétudes ou problèmes de qualité en de nombreux endroits, et surfrir un excellent avantage de prix.
N'hésitez pas à nous appeler pour plus de détails sur les produits.