HIMA F6251 984625102 Safety-Related Monitor

Produkteinführung The HIMA F6251 is a high-reliability safety-related limit monitor designed for critical industrial applications requiring precise monitoring von process parameters. Manufactured by

Artikelnummer: 2911 Auf Lager
HIMA F6251 984625102 Safety-Related Monitor

Produktspezifikationen

ErscheinungsdatumJul 07, 2026
Hersteller Hima DCS-Module
Modell F6251 984625102
Artikelnummer IN2911
Zustand100 % neu
VersandhafenXiamen, China
Lieferzeit1-3 Werktage
ZertifikatCOO
KurierpartnerDHL, UPS, TNT, FedEx and EMS.
Garantie 1 Jahr
Stückpreis
$1,299.00
USD / Einheit
-
+
Mindestbestellung: 1 Stück
0.0


Versandinformationen
Kostenloser Versand für Bestellungen über $5,000
Bei Bestellungen vor 15:00 Uhr EST erfolgt der Versand am selben Tag.
Internationaler Versand verfügbar
HIMA F6251 984625102 Safety-Related Monitor HIMA F6251 984625102 Safety-Related Monitor HIMA F6251 984625102 Safety-Related Monitor HIMA F6251 984625102 Safety-Related Monitor

Produkteinführung

The HIMA F6251 is a high-reliability safety-related limit monitor designed for critical industrial applications requiring precise monitoring von process parameters. Manufactured by HIMA, a leading German company specializing in safety automation solutions, the F6251 ensures rapid detection and response to deviations in process limits, thereby enhancing plant safety and compliance with international safety standards. It is widely utilized in industries such as oil & gas, chemical processing, and power generation, where safety is paramount.


Produktspezifikationen

Parameter Beschreibung
Modell Number F6251
Artikelnummer 984625102
Hersteller HIMA
Product Type Safety-Related Limit Monitor
Input Signal Type Analog (0–10V, 4–20mA) / Digital
Number von Inputs 2 redundant channels
Response Time < 10 ms
Operating Voltage 24 VDC nominal (19.2V to 30V range)
Power Consumption ≤ 5W
Operating Temperature -25°C to +70°C
Storage Temperature -40°C to +85°C
Relative Humidity 5% to 95% non-condensing
Safety Integrity Level (SIL) SIL 3 per IEC 61508
Mounting Type DIN rail mounting
Dimensions (H x W x D) 120 x 80 x 40 mm
Gewicht 0.159 kg
Communication Interface HIMA proprietary system bus
Protection Class IP20 (for control cabinet installation)
Certifications CE, ATEX (Zone 2), TÜV Rheinland (Functional Safety), EN 50156-2 compliant

Product Applications

  • Process Limit Monitoring: Ensures that critical process parameters remain within predefined safety limits, triggering alarms or shutdowns upon deviations.

  • Emergency Shutdown Systems (ESD): Integrates into ESD systems to provide rapid response to hazardous conditions, safeguarding personnel and equipment.

  • Redundant Safety Architectures: Supports dual-channel configurations for high-availability systems requiring redundancy.

  • Industrial Automation: Applicable in various industries, including oil & gas, chemical processing, and power generation, for enhancing operational safety.


Product Advantages

  • High Reliability: Designed for continuous operation in demanding industrial environments, ensuring consistent performance.

  • Rapid Response: Fast detection and reaction to process deviations (<10 ms response time), minimizing potential hazards.

  • Compact Design: Slim prvonile (20 mm width) facilitates easy integration into existing control panels without requiring significant space.

  • Robust Construction: Built to withstand harsh conditions, including wide temperature ranges and high humidity levels.

  • Compliance with Safety Standards: Certified to SIL 3 per IEC 61508, ensuring adherence to international safety requirements.

  • Ease von Integration: Compatible with HIMA’s proprietary system bus, allowing seamless communication within HIMA safety systems.


Häufig gestellte Fragen (FAQ)

  1. What is the primary function von the HIMA F6251?
    The F6251 is designed to monitor process parameters and ensure they remain within predefined safety limits, triggering appropriate responses when deviations occur.

  2. What types von input signals does the F6251 accept?
    It accepts both analog (0–10V, 4–20mA) and digital signals, providing flexibility in monitoring various process variables.

  3. Is the F6251 suitable for use in hazardous areas?
    Yes, it is certified for use in ATEX Zone 2 hazardous areas, making it suitable for environments with explosive atmospheres.

  4. What is the Safety Integrity Level (SIL) rating von the F6251?
    The F6251 is certified to SIL 3 according to IEC 61508 standards, indicating a high level von safety performance.

  5. Can the F6251 be integrated into existing HIMA safety systems?
    Yes, it features a proprietary system bus interface for seamless integration with other HIMA components.

  6. What is the response time von the F6251?
    The module has a rapid response time von less than 10 milliseconds, ensuring prompt action upon detecting parameter deviations.

  7. What are the mounting options for the F6251?
    It is designed for DIN rail mounting, facilitating easy installation within control cabinets.

  8. What environmental conditions can the F6251 withstand?
    The module operates within a temperature range von -25°C to +70°C and can be stored between -40°C and +85°C, with humidity levels from 5% to 95% non-condensing.

  9. Does the F6251 support redundant configurations?
    Yes, it features two redundant input channels, enhancing system reliability through redundancy.

  10. What certifications does the F6251 hold?
    The module is certified by TÜV Rheinland for functional safety and complies with CE, ATEX (Zone 2), and EN 50156-2 standards.


Related Modells from the Same Series or Functionality

Modell Beschreibung Input Type SIL Rating Dimensions (mm) Gewicht (g)
F3331 8-Channel Safety-Related Output Module Digital Outputs SIL 3 119 x 89 x 45 113
F3334 Safety-Related Controller with Counters and Analog Inputs Analog/Digital Inputs SIL 3 100 x 50 x 25 150
F3316 Safety Systems Input Module with Dual-CPU Architecture Digital Inputs SIL 3 100 x 50 x 20 100
F3324 High-Performance Safety Relay for ESD Systems Digital Inputs SIL 3 22.5 x 99 x 114 150
F30 Compact Safety Controller for Industrial Applications Digital I/O SIL 3 51 x 127 x 51 500
62100 2-Channel Limit Monitor for Analog Signals Analog Inputs SIL 4 45 x 100 x 22.5 1000

Popular Modells from HIMA (Same Marke)

Modell Beschreibung Function SIL Rating Dimensions (mm) Gewicht (g)
F8627X Safety Controller with Modular Design and Ethernet Communication Safety Controller SIL 3 145 x 100 x 62 450
F8652X High-Performance Safety Controller for Hazardous Environments Safety Controller SIL 3/4 100 x 50 x 25 150
F30 Compact Safety Controller for Industrial Applications Safety Controller SIL 3 51 x 127 x 51 500
F3331 8-Channel Safety-Related Output Module Output Module SIL 3 119 x 89 x 45 113
F3334 Safety-Related Controller with Counters and Analog Inputs Controller Module SIL 3 100 x 50 x 25 150
F3316 Safety Systems Input Module with Dual-CPU Architecture Input Module SIL 3 100 x 50 x 20 100

Unternehmensinformationen

E-mail: [email protected]

Mobile:Bitte kontaktieren Sie uns per E-Mail

Whatsapp:Bitte kontaktieren Sie uns per E-Mail

Add: Alishan Building, 2 Lvling Rd, Bezirk Siming, Xiamen, Fujian, China, 361006

Unsere Dienstleistungen

Wir sind spezialisiert auf die Lieferung von Industrieautomatisierungsteilen mit einjähriger Garantie. Unsere Industrieautomatisierungsteile werden weltweit verkauft.

Wir können Geräte und Ersatzteile aus verschiedenen Ländern und von verschiedenen Herstellern liefern, Ihre Sorgen oder Qualitätsprobleme an vielen Orten lösen und bieten einen großen Preisvorteil.

Rufen Sie uns gerne an für weitere Produktdetails.

Produktgarantie & Kundensicherheit

Garantiedetails
  • 2 Jahre Standardgarantie – Abdeckung von Material- und Verarbeitungsfehlern
  • Optionale erweiterte Abdeckung – Garantieverlängerung bis zu 5 Jahren
  • Technischer Vor-Ort-Support – Werksgeschulte Ingenieure für den Service verfügbar
  • Austauschprogramm – Priorisierter Austausch innerhalb von 48 Stunden
  • Kontinuierliche technische Unterstützung – Lebenslanger Support für alle Produkte
Qualitätskonformität
  • 100 % getestet und verifiziert – Jede Einheit vor dem Versand geprüft
  • ISO 9001 zertifiziert – Einhaltung des Qualitätsmanagementsystems
  • Umweltkonformität – RoHS- und CE-Normen erfüllt
  • Globale Sicherheitszertifizierungen – UL, cUL und andere anwendbare Zertifizierungen
  • Rückverfolgbare Produktion – Vollständige Serien- und Chargenrückverfolgbarkeit
Rückgabe- und Umtauschrichtlinie
  • 30-tägiges Rückgaberecht – Rückerstattung für ungenutzte Produkte
  • Keine Wiederauffüllungsgebühren – Rücksendungen ohne zusätzliche Gebühren
  • Kostenloser Rückversand – Bei defekten oder falschen Artikeln
  • Cross-Versand-Support – Minimierung der Ausfallzeiten während des Austauschs
  • Einfacher RMA-Prozess – Online-Rückgabeautorisierung verfügbar
Kundenrechte & Support
  • Preisgarantie – 30-tägiger Preisschutz
  • Reservierter Bestand – Bevorzugter Bestand für Stammkunden
  • Technische Schulung – Produktschulungen online und vor Ort verfügbar
  • Integrationshilfe – Technische Unterstützung für SPS/DCS-Integration
  • Support für ältere Produkte – Fortgesetzter Service für ausgelaufene Module
Garantiebedingungen
Abgedeckte Artikel:
  • Herstellungsfehler bei Materialien und Verarbeitung
  • Komponentenausfälle bei normaler Nutzung
  • Firmware- oder Svontwareprobleme (Updates werden bereitgestellt)
  • Fehler oder Auslassungen in der Dokumentation
Ausschlüsse:
  • Falsche Installation oder unsachgemäße Verwendung
  • Nicht autorisierte Änderungen oder Reparaturen
  • Schäden durch Unfälle, Missbrauch oder Vernachlässigung
  • Normale Abnutzung im Laufe der Zeit
Wichtige Hinweise:
  • Alle Garantie- oder Rückgabeanfragen erfordern einen Kaufnachweis
  • Die Originalverpackung sollte für Rücksendungen aufbewahrt werden
  • Kundenspezifisch konfigurierte oder Sonderbestellungen können abweichende Rückgabebedingungen haben
  • Internationale Sendungen können zusätzliche Bearbeitungs- oder Versandanforderungen haben

Technische Dokumentation

Check out HIMA F6251 984625102 Safety-Related Monitor latest technical documentation.

Kundenbewertungen

Bewertung hinterlassen

Bitte kontaktieren Sie uns per E-Mail [email protected] Bitte kontaktieren Sie uns per E-Mail Follow us on Facebook Subscribe on YouTube