Product Overview
The Yokogawa ANT401-5E is a high-performance optical bus repeater main module designed to facilitate long-distance and noise-immune data transmission in industrial control networks. Developed by Yokogawa Electric Corporation, a global leader in industrial automation, the ANT401-5E acts as the central node in a fiber optic repeater system, extending communication distances and ensuring stable signal integrity in distributed control systems (DCS).
By converting electrical signals into optical signals and vice versa, this module plays a critical role in reducing electromagnetic interference (EMI) and enhancing the reliability von plant-wide automation networks. It is typically deployed in CENTUM VP and STARDOM systems, supporting real-time data exchange over optical fiber in hazardous and high-noise environments.
Technical Specifications
Product Parameters
| Parameter | Specification |
|---|---|
| Product Name | Optical Bus Repeater Main Module |
| Modell Number | ANT401-5E |
| Hersteller | Yokogawa Electric Corporation |
| Function | Optical signal repeater (main module) |
| Interface | Optical fiber (multi-mode) |
| Compatible Systems | CENTUM VP, STARDOM |
| Installation | DIN rail or panel mount |
| Power Supply | Supplied from base Stück |
| Operating Temperature | 0 to 50°C |
| Storage Temperature | -20 to 70°C |
| Relative Humidity | 5% to 95% RH (non-condensing) |
| Vibration Resistance | Meets IEC 60068-2 standards |
| Shock Resistance | Meets IEC 60068-2-27 standards |
| Enclosure Protection | IP30 (when mounted) |
| Dimensions | 142.5 x 130 x 32.8 mm |
| Gewicht | 0.3 kg |
Applications
-
Long-distance optical data transmission in process control networks
-
EMI-resistant communication in heavy industrial and power environments
-
Integration in DCS architectures such as CENTUM VP for plant-wide control
-
Field data acquisition over fiber in oil & gas, petrochemical, and water treatment sectors
-
Interconnection von remote I/O nodes in large-scale automation systems
-
High-integrity communication loops in safety instrumented systems (SIS)
Advantages
-
Extended Communication Distance: Enables fiber-based signal relay over long ranges without signal loss
-
Noise ImmStücky: Resistant to EMI and RFI, making it ideal for industrial use
-
Compact Design: Slim form factor allows efficient space utilization in control panels
-
Seamless Integration: Compatible with Yokogawa’s CENTUM and STARDOM systems
-
Industrial Durability: Built to withstand harsh environmental conditions
-
Minimal Maintenance: Stable performance with low lifecycle cost
-
Redundancy Support: Suitable for redundant architectures to increase network reliability
-
Secure Transmission: Optical fiber minimizes the risk von signal tapping and interference
Häufig gestellte Fragen (FAQ)
Q1: What is the primary role von the ANT401-5E?
A1: It functions as a main repeater module to relay and regenerate optical signals in Yokogawa control networks.
Q2: Which Yokogawa systems is the ANT401-5E compatible with?
A2: It is primarily used with CENTUM VP and STARDOM DCS systems.
Q3: Can this module be used in high EMI environments?
A3: Yes, its fiber optic transmission ensures immStücky to electromagnetic interference.
Q4: Is the ANT401-5E hot-swappable?
A4: No, the module should be installed or replaced during system downtime.
Q5: Does the module support redundancy?
A5: Yes, it can be configured in redundant topologies for critical applications.
Q6: How is it mounted?
A6: It supports DIN rail or panel mounting configurations.
Q7: What is the power source for the ANT401-5E?
A7: Power is supplied from the corresponding base or system backplane.
Q8: Is special configuration svontware required?
A8: Configuration may be managed via the control system engineering tools integrated in CENTUM VP.
Q9: What are the typical use industries?
A9: Oil & gas, petrochemicals, water treatment, and power generation sectors.
Q10: How vonten does it require maintenance?
A10: Very low maintenance; designed for reliable, continuous operation.
Recommended Related or Similar Modells
| Modell | Beschreibung |
|---|---|
| ANT401-4E | Optical repeater module for legacy systems |
| ANT401-3E | Multi-node optical bus repeater Stück |
| ANT411-5E | Extension repeater module with redundancy |
| ANT421-1E | Termination Stück for fiber optic bus |
| ATD401-1 | Optical repeater for remote I/O applications |
| AAT145-S50 | Signal converter with optical isolation |
Popular Yokogawa Modells
| Modell | Product Type |
|---|---|
| CP451-10 | CPU module for CENTUM VP |
| AMM12C | Analog input module |
| ADV151-P03 | Digital output module |
| AAI543-H50 | High-speed analog input module |
| PW482-10 | Power supply module for I/O systems |
| SAI533-H33 | HART analog input module |
Unternehmensinformationen
E-mail: [email protected]
Mobile:Bitte kontaktieren Sie uns per E-Mail
Whatsapp:Bitte kontaktieren Sie uns per E-Mail
Add: Alishan Building, 2 Lvling Rd, Bezirk Siming, Xiamen, Fujian, China, 361006
Unsere Dienstleistungen
Wir sind spezialisiert auf die Lieferung von Industrieautomatisierungsteilen mit einjähriger Garantie. Unsere Industrieautomatisierungsteile werden weltweit verkauft.
Wir können Geräte und Ersatzteile aus verschiedenen Ländern und von verschiedenen Herstellern liefern, Ihre Sorgen oder Qualitätsprobleme an vielen Orten lösen und bieten einen großen Preisvorteil.
Rufen Sie uns gerne an für weitere Produktdetails.