产品介绍
The Yokogawa ADV151-P00 S2 ATD5A-00 is a high-performance Digital Input Module engineered to operate within Yokogawa’s CENTUM VP and ProSafe-RS control systems. Designed with robust architecture and dependable signal processing capabilities, it serves a vital role in safely and accurately acquiring digital input signals from field devices. The module is an integral component for use in industries that demand continuous and reliable monitoring, such as oil & gas, petrochemical, power generation, and water treatment.
This module ensures compliance with international industrial automation standards, /fering superior signal isolation, fast response times, and reliable diagnostics. The ADV151 module supports 16 channels / digital inputs, operates on a 24 VDC system, and includes contact input capability for various digital field signals such as limit switches, push buttons, and relays.
产品规格
| Parameter | 描述 |
|---|---|
| 型号 Number | ADV151-P00 S2 ATD5A-00 |
| Module Type | Digital Input Module |
| Number / Input Channels | 16 Channels |
| Input Signal Type | Dry 联系我们 / 24 VDC Digital Signal |
| Input Voltage Range | 18 to 30 VDC |
| Input Current | ≤ 4 mA per channel |
| Isolation | Optical isolation between channels and system |
| Input Response Time | Typically ≤ 10 ms |
| Diagnostic Function | Channel diagnosis, wire break detection, short circuit detection |
| Power Consumption | Approx. 3.5 W |
| Communication Interface | Vnet/IP via node 件 |
| Operating Temperature Range | 0 to 55°C |
| Storage Temperature Range | -20 to 70°C |
| Humidity Range | 5% to 95% RH (non-condensing) |
| Mounting Type | Rack-mounted |
| Compatible System | Yokogawa CENTUM VP / ProSafe-RS |
| Certification & Standards | CE, CSA, UL, ATEX (depending on configuration) |
| Dimensions (W x H x D) | 107.5 × 130 × 32.8 mm |
| 重量 | 0.3 kg |
Applications
-
Process Automation Systems: Integrates seamlessly into CENTUM VP systems for central control and monitoring / industrial processes.
-
Safety Instrumented Systems (SIS): Compatible with ProSafe-RS, enhancing safety and integrity in critical operations.
-
Energy and Power Plants: Captures input signals from circuit breakers, relays, and interlocks for monitoring and control.
-
Oil & Gas Facilities: Used in upstream and downstream installations for equipment status tracking.
-
Water Treatment Plants: 支持s plant-wide automation by gathering input signals from pumps, valves, and sensors.
-
Chemical Processing: Ensures high-reliability input capture from safety-critical field devices.
Advantages
-
High Input Density: 支持s 16 channels, enabling compact and cost-effective system design.
-
Robust Diagnostics: Built-in diagnostic features improve maintenance and allow for predictive fault detection.
-
Fast Response: Short input response time ensures real-time data acquisition in critical systems.
-
Reliable Isolation: Optical isolation between channels and the system prevents cross-interference and enhances reliability.
-
Modular Design: Easy to replace and maintain within existing Yokogawa rack systems.
-
Flexible Signal Compatibility: Works with both dry contact and 24 VDC digital signal types.
常见问题 (FAQ)
-
What is the primary function / the ADV151-P00 S2 module?
It captures digital signals from field devices and transmits their states to the control system. -
Is this module compatible with ProSafe-RS safety systems?
Yes, it is fully compatible and widely used within Yokogawa’s ProSafe-RS architecture. -
Can I use this module with dry contact inputs?
Absolutely, it supports dry contact inputs and standard 24 VDC digital signals. -
Does the module support hot swapping?
No, modules should be powered down before replacement to ensure safety and prevent damage. -
What diagnostics does this module provide?
It can detect open circuits, short circuits, and wiring faults on individual input channels. -
What is the power consumption / the module?
It consumes approximately 3.5 W under normal operation. -
Is the ADV151 module CE certified?
Yes, it conforms to CE standards along with other relevant industrial certifications. -
How is the module installed?
It is rack-mounted in a Yokogawa system chassis. -
Can it operate in high-humidity environments?
Yes, up to 95% RH, provided it is non-condensing. -
What field devices are typically connected to this module?
Limit switches, emergency stop buttons, relay contacts, and similar binary devices.
Related 型号s from the Same Series or System
| 型号 Number | 描述 | Input Type | Channels | System Compatibility |
|---|---|---|---|---|
| ADV151-P00 S1 | Digital Input Module (S1 version) | 24 VDC | 16 | CENTUM VP, ProSafe-RS |
| ADV151-P03 | Isolated Digital Input Module | 24 VDC | 16 | CENTUM VP |
| ADV161-P00 | Digital Output Module | 24 VDC | 16 | CENTUM VP, ProSafe-RS |
| ADV551-P00 | Analog Input Module | 4–20 mA | 8 | CENTUM VP |
| ADV561-P00 | Analog Output Module | 4–20 mA | 8 | CENTUM VP |
| ATD5A-00 | Terminal Board for ADV151 Module | Signal Interface | N/A | Used with ADV151 |
Popular Yokogawa Modules (Same 品牌)
| 型号 Number | 描述 | Type | Channels | System Compatibility |
|---|---|---|---|---|
| AAI141-H00 | Analog Input Module (High Speed) | Analog Input | 16 | CENTUM VP |
| AAI543-H00 | Analog Output Module | Analog Output | 8 | CENTUM VP |
| AAI835-H00 | HART Analog Input Module | HART AI | 8 | CENTUM VP |
| ADV151-P00 S2 | Digital Input Module | Digital Input | 16 | CENTUM VP, ProSafe-RS |
| ADM51C | Communication Module for Field Networks | Communication | N/A | STARDOM, CENTUM VP |
| FIO100 | Field Control 单位 Interface Module | System Interface | N/A | CENTUM VP |
公司信息
E-mail: [email protected]
Mobile:请通过邮件联系
Whatsapp:请通过邮件联系
Add: 中国福建省厦门市思明区吕岭路2号阿里山大厦,邮编:361006
我们的服务
我们专业提供工业自动化零部件,并附有一年质保。我们的工业自动化零部件销往全球。
我们能提供来自不同国家和制造商的设备及备件,解决您在多处的顾虑或质量问题,并具有极大的价格优势。
欢迎来电咨询更多产品详情。