产品介绍 The Yokogawa ADM52-2 S4 is a high-performance contact output module designed for use within distributed control systems (DCS) and programmable logic controller (PLC) applications.

零件号: 2289
TAGS:
有库存
Yokogawa ADM52-2 S4 联系我们 Output Module

产品规格

发布时间Jul 07, 2026
制造商 横河
型号 ADM52-2 S4
零件号 IN2289
状态100% 全新
发货港口中国厦门
交货时间1-3 个工作日
证书COO
快递合作伙伴DHL, UPS, TNT, FedEx and EMS.
保修 1 年
单价
$349.00
USD / 单位
-
+
最小起订量: 1 件
0.0


运输信息
订单满额免运费 $5,000
美国东部时间下午 3 点前下单,当日发货
提供国际运输
Yokogawa ADM52-2 S4 联系我们 Output Module Yokogawa ADM52-2 S4 联系我们 Output Module Yokogawa ADM52-2 S4 联系我们 Output Module Yokogawa ADM52-2 S4 联系我们 Output Module

产品介绍

The Yokogawa ADM52-2 S4 is a high-performance contact output module designed for use within distributed control systems (DCS) and programmable logic controller (PLC) applications. As part / Yokogawa’s reputable CENTUM and ProSafe product lines, this module provides reliable and durable output switching functions via dry contact relays. The ADM52-2 S4 is engineered to handle industrial-grade loads and deliver high isolation and fail-safe protection, making it ideal for mission-critical operations in oil and gas, chemical, power, and other process industries.

This module is equipped with 16 independent channels, each capable / switching field devices such as alarms, solenoids, and contactors. With robust electrical isolation and self-diagnostic features, the ADM52-2 S4 ensures safety and system stability across diverse field conditions.


Technical Specifications

Parameter Value
型号 ADM52-2 S4
制造商 横河 Corporation
Type 联系我们 Output Module (Relay Output)
Channels 16 independent output channels
Output Type Dry 联系我们 (Form A SPST-NO)
Rated Load Voltage 24V DC / 110V AC
Maximum Load Current 2 A per channel
Response Time < 10 ms
Isolation Voltage 1500 V AC (Channel to Channel, Channel to Ground)
Diagnostics Channel status, module status, fail-safe
Connector Type Removable terminal block
Power Supply Supplied via system backplane
Power Consumption Approx. 5 W
Operating Temperature -20°C to +70°C
Storage Temperature -40°C to +85°C
Humidity 5% to 95% RH, non-condensing
Dimensions (W x H x D) 130 × 100 × 30 mm
重量 1.5 kg
Mounting DIN rail or baseplate
Certifications CE, CSA, UL, ATEX, SIL2/3 (depending on system)

Applications

  • Distributed Control Systems (DCS): Ideal for interfacing with field output devices such as solenoids, contactors, and relays.

  • Emergency Shutdown Systems (ESD): Used for safety interlocking and contact control within safety systems.

  • Oil & Gas Platforms: 联系我们 output to control relays, flares, ESD valves, and signal devices.

  • Power Plants: Monitoring and actuating various components in SCADA and plant control systems.

  • Chemical Processing Plants: Critical output operations in batch and continuous processing.

  • Water & Wastewater Treatment: Used in output signaling for pumps, motors, and alarm systems.


Product Advantages

  • High Reliability: Built for industrial applications with robust dry contact relay outputs.

  • Electrical Isolation: Strong channel-to-channel and channel-to-ground isolation enhances system safety.

  • Fail-Safe Capabilities: 支持s output status hold or default fallback during system faults.

  • Compact Design: Space-saving form factor suited for dense cabinet installations.

  • Diagnostic Features: Real-time status monitoring ensures rapid troubleshooting and minimized downtime.

  • Long Lifecycle: Engineered for extended service life with minimal maintenance.

  • Plug-and-Play Installation: Easy installation and replacement due to modular architecture.

  • Certified Safety Compliance: SIL2/SIL3 suitable when integrated into certified safety systems.


常见问题 (FAQ)

  1. What is the function / the ADM52-2 S4 module?
    The ADM52-2 S4 provides 16-channel contact outputs for interfacing with field devices in industrial automation systems.

  2. Is the ADM52-2 S4 suitable for safety-related applications?
    Yes, it supports fail-safe operations and is suitable for SIL2/SIL3 systems when used within a certified environment.

  3. Can I use this module in a hazardous area?
    Yes, with appropriate barriers and compliance with system certifications (e.g., ATEX), it can be deployed in hazardous zones.

  4. What type / loads can the output contacts switch?
    The module is designed for low- to moderate-load switching, such as alarms, relays, and solenoids (up to 2 A per channel).

  5. Does the module support hot swapping?
    Depending on the host system, it may support online replacement without shutting down the entire system.

  6. How is the module mounted in the system?
    It can be mounted on DIN rails or system baseplates according to cabinet design.

  7. Is there built-in diagnostic support?
    Yes, the module supports LED and s/tware-based diagnostics for each channel and the module itself.

  8. What is the module’s response time?
    The typical switching response time is less than 10 milliseconds.

  9. What happens in case / system power failure?
    The module can be configured to retain its output status or fall to a predefined safe state.

  10. How does it communicate with the control system?
    Communication is managed via the backplane bus integrated into the system rack or controller base.


Related 型号s (Same or Similar Series)

型号 Number 描述 Output Type Channels Certifications
ADM51-2 S4 Digital contact output module Relay 8 CE, UL
ADM53-2 S4 High-capacity output module Relay 16 SIL3, CE
ADM12-2 S4 Transistor output module NPN 16 CE, UL
ADM92-2 S4 联系我们 output with built-in diagnostics Relay 8 SIL2, CSA
ADV52-2 S4 Analog output module Analog 8 CE, UL
ADM56-2 S4 联系我们 output with enhanced isolation Relay 16 CE, ATEX

Popular Yokogawa Modules

型号 Number 描述 Type Channels 重量
ADV151-P03 Analog Input Module (Voltage) Analog Input 16 350 g
ADM11-2 S4 Digital Output Module Relay Output 8 300 g
AAI143-H50 Analog Input (High-speed HART) Analog Input 16 370 g
AAI543-H50 Analog Input Redundant Module Analog Input 16 380 g
AAR181-S00 Remote I/O Subsystem Interface Communication 420 g
AAI841-H50 Analog Input (Differential HART) Analog Input 8 360 g

公司信息

E-mail: [email protected]

Mobile:请通过邮件联系

Whatsapp:请通过邮件联系

Add: 中国福建省厦门市思明区吕岭路2号阿里山大厦,邮编:361006

我们的服务

我们专业提供工业自动化零部件,并附有一年质保。我们的工业自动化零部件销往全球。

我们能提供来自不同国家和制造商的设备及备件,解决您在多处的顾虑或质量问题,并具有极大的价格优势。

欢迎来电咨询更多产品详情。

产品保修与客户保障

保修详情
  • 2 年标准保修 – 涵盖材料和工艺缺陷
  • 可选延长保修 – 将保修期延长至 5 年
  • 现场技术支持 – 提供经过工厂培训的工程师服务
  • 更换计划 – 48 小时内优先更换
  • 持续的技术协助 – 所有产品的终身支持
质量合规
  • 100% 测试与验证 – 每件产品发货前均经过检查
  • ISO 9001 认证 – 遵守质量管理体系
  • 环境合规 – 符合 RoHS 和 CE 标准
  • 全球安全认证 – UL、cUL 及其他适用认证
  • 可追溯生产 – 完整的序列号和批次可追溯性
退换货政策
  • 30 天退货期 – 未使用产品的退款
  • 无补货费 – 退货处理不收取额外费用
  • 免费退货运费 – 针对有缺陷或错误的商品
  • 交叉发货支持 – 在更换期间最大限度地减少停机时间
  • 简单的 RMA 流程 – 提供在线退货授权
客户权益与支持
  • 价格匹配保证 – 30 天产品价格保护
  • 预留库存 – 为回头客提供优先库存
  • 技术培训 – 提供在线和现场产品培训课程
  • 集成协助 – 为 PLC/DCS 集成提供工程支持
  • 旧型号产品支持 – 为已停产的模块持续提供服务
保修条款与条件
涵盖项目:
  • 材料和工艺方面的制造缺陷
  • 正常使用下的组件故障
  • 固件或软件问题(提供更新)
  • 文档中的错误或遗漏
除外条款:
  • 错误安装或不当使用
  • 未经授权的修改或维修
  • 事故、误用或疏忽造成的损坏
  • 随时间的正常磨损
重要说明:
  • 所有保修或退货请求均需提供购买凭证
  • 退货时应保留原包装
  • 定制配置或特殊订单产品可能有不同的退货条件
  • 国际运输可能需要考虑额外的处理或运输事项

技术文档

Check out Yokogawa ADM52-2 S4 联系我们 Output Module latest technical documentation.

客户评价

发表评论

请通过邮件联系 [email protected] 请通过邮件联系 Follow us on Facebook Subscribe on YouTube