报价 (0)

Yokogawa AAI143-S03 Analog Input Module

产品介绍 The Yokogawa AAI143-S03 is a 16-channel analog input module specifically engineered for integration within the CENTUM VP and CENTUM CS 3000 distributed control systems (DCS) . It

零件号: 1782
TAGS:
有库存
Yokogawa AAI143-S03 Analog Input Module

产品规格

发布时间Jul 07, 2026
制造商 横河
型号 AAI143-S03
零件号 IN1782
状态100% 全新
发货港口中国厦门
交货时间1-3 个工作日
证书COO
快递合作伙伴DHL, UPS, TNT, FedEx and EMS.
保修 1 年
单价
$1,059.00
USD / 单位
-
+
最小起订量: 1 件
0.0


运输信息
订单满额免运费 $5,000
美国东部时间下午 3 点前下单,当日发货
提供国际运输
Yokogawa AAI143-S03 Analog Input Module Yokogawa AAI143-S03 Analog Input Module Yokogawa AAI143-S03 Analog Input Module Yokogawa AAI143-S03 Analog Input Module

产品介绍

The Yokogawa AAI143-S03 is a 16-channel analog input module specifically engineered for integration within the CENTUM VP and CENTUM CS 3000 distributed control systems (DCS). It is designed for precise and reliable acquisition / analog process signals, ensuring seamless communication between field instruments and control systems.

This model is optimized for standard 4–20 mA DC signals, and unlike HART-enabled variants, it focuses on cost-effective high-density signal acquisition without the additional overhead / digital communication protocols. This makes it particularly well-suited for systems where HART communication is unnecessary, but reliable signal input and high system performance are essential.

Built with industry-grade robustness, the AAI143-S03 supports high-speed data processing, signal integrity, and diagnostic capabilities, contributing to reduced downtime, greater control accuracy, and extended system scalability.


产品规格

Parameter Specification
型号 Number AAI143-S03
Module Type Analog Input Module
Input Channels 16 channels
Input Signal Type 4–20 mA DC (non-HART)
Input Resistance 250 Ω (typical)
Resolution 16 bits
Data Update Rate 100 ms
Isolation Type Optical isolation (channel-to-bus and field-to-system)
Power Supply Voltage Supplied via base plate
Power Consumption Approx. 3.3 W
Installation Type Mounted on N-IO baseplate
Operating Temperature Range 0 to 50°C (32 to 122°F)
Storage Temperature Range -20 to 70°C (-4 to 158°F)
Humidity Range 5% to 95% RH (non-condensing)
Built-in Diagnostics Overrange, underrange, open input detection
Certifications CE, KC, compliant with marine and hazardous area standards
Communication Internal system bus only (no HART protocol)
Dimensions (H × W × D) 107.5 × 32.8 × 130 mm
重量 0.3 kg

Product Applications

The AAI143-S03 is widely used in process automation and control systems where reliable analog signal acquisition is essential, but HART communication is not required. This makes it a cost-efficient choice for core industrial automation functions, such as:

  • Oil & gas plant automation

  • Chemical and petrochemical processing

  • Power generation facilities

  • Pulp and paper industries

  • Water and wastewater treatment

  • Steel and metal processing

  • Batch control in pharmaceuticals


Product Advantages

  • High-Density Analog Input
    With 16 input channels, the module allows for efficient signal collection from multiple transmitters, reducing module count and wiring complexity.

  • Robust Signal Isolation
    Optical isolation ensures electrical noise and signal interference are minimized, enhancing system stability and integrity.

  • Accurate and Fast Conversion
    A 16-bit resolution and fast 100 ms data refresh rate support precise monitoring / process variables.

  • Cost-Efficient Architecture
    The S03 model excludes HART features, /fering a streamlined and budget-friendly option for analog input in environments where smart communication is unnecessary.

  • Seamless Integration
    Fully compatible with Yokogawa’s CENTUM VP/CS 3000 systems, ensuring effortless hardware and s/tware integration.

  • Built-in Diagnostics
    Internal monitoring functions alert the control system / signal anomalies, allowing operators to react to wiring faults or instrument failures in real time.

  • Environmental Durability
    支持s wide operating temperatures and relative humidity, suitable for rugged industrial installations.


FAQ

  1. Does the AAI143-S03 module support multi-channel simultaneous input?
    Yes, all 16 channels can receive inputs simultaneously; each is independently processed.

  2. How does the module handle over-range or under-range signals?
    It features internal detection that flags such conditions to the DCS for safety and diagnostics.

  3. Is the AAI143-S03 compatible with non-standard 4–20 mA devices?
    It is optimized for standard 4–20 mA signals; non-standard inputs may require signal conditioning.

  4. Can the module detect open circuits in the input loop?
    Yes, open input circuit detection is built-in to ensure timely fault identification.

  5. Is there internal averaging or filtering applied to signal inputs?
    Basic digital filtering is performed to ensure signal stability; advanced processing is handled by the DCS.

  6. Does the module require external power for field inputs?
    Field transmitters require external loop power; the module itself is powered via the baseplate.

  7. What is the input impedance / each channel?
    Each input has a typical resistance / 250 ohms.

  8. Is it possible to replace this module online without shutting down the system?
    Hot-swapping may be supported depending on system configuration and redundancy setup.

  9. Can it be used in SIL-rated applications?
    While the module itself is not SIL-rated, it can be part / a SIL-certified system if applied correctly.

  10. How is grounding managed for input channels?
    The module uses floating inputs with isolation; proper grounding practices should still be observed at the cabinet level.


Related 型号s from the Same Series

型号 Number 描述 Channels Signal Type Special Feature
AAI143-H5 Analog Input Module with HART 支持 16 4–20 mA DC HART communication enabled
AAI145-S00 High Accuracy Analog Input Module 8 4–20 mA DC High precision, low noise input
AAI141-S00 Standard Analog Input Module 16 1–5 V or 4–20 mA Basic analog input
AAI543-S00 Differential Analog Input Module 8 ±10 V DC For differential voltage signals
AAI835-S00 Temperature Input Module 16 Thermocouple/RTD Multi-type thermal sensors
ADV551-P50 Analog Output Module 8 4–20 mA DC Output signal control

Popular Yokogawa Modules (Same 品牌)

型号 Number 描述 Channels Type Application
ADV151-P03 Digital Input Module 32 联系我们 Input Binary signal acquisition
ADV551-P00 Analog Output Module 8 4–20 mA DC Field actuator control
AAR181-S50 Remote I/O Communication Module N/A Ethernet/Fieldbus Remote I/O system communication
AAI841-S00 High-Speed Analog Input Module 4 Voltage/Current For high-speed batch processes
AAI835-H50 Temperature Input Module 16 RTD/Thermocouple Multi-channel temperature inputs
ADM111-S03 Pulse Input Module 2 Frequency/Pulse Flow or speed measurement

公司信息

E-mail: [email protected]

Mobile:请通过邮件联系

Whatsapp:请通过邮件联系

Add: 中国福建省厦门市思明区吕岭路2号阿里山大厦,邮编:361006

我们的服务

我们专业提供工业自动化零部件,并附有一年质保。我们的工业自动化零部件销往全球。

我们能提供来自不同国家和制造商的设备及备件,解决您在多处的顾虑或质量问题,并具有极大的价格优势。

欢迎来电咨询更多产品详情。

产品保修与客户保障

保修详情
  • 2 年标准保修 – 涵盖材料和工艺缺陷
  • 可选延长保修 – 将保修期延长至 5 年
  • 现场技术支持 – 提供经过工厂培训的工程师服务
  • 更换计划 – 48 小时内优先更换
  • 持续的技术协助 – 所有产品的终身支持
质量合规
  • 100% 测试与验证 – 每件产品发货前均经过检查
  • ISO 9001 认证 – 遵守质量管理体系
  • 环境合规 – 符合 RoHS 和 CE 标准
  • 全球安全认证 – UL、cUL 及其他适用认证
  • 可追溯生产 – 完整的序列号和批次可追溯性
退换货政策
  • 30 天退货期 – 未使用产品的退款
  • 无补货费 – 退货处理不收取额外费用
  • 免费退货运费 – 针对有缺陷或错误的商品
  • 交叉发货支持 – 在更换期间最大限度地减少停机时间
  • 简单的 RMA 流程 – 提供在线退货授权
客户权益与支持
  • 价格匹配保证 – 30 天产品价格保护
  • 预留库存 – 为回头客提供优先库存
  • 技术培训 – 提供在线和现场产品培训课程
  • 集成协助 – 为 PLC/DCS 集成提供工程支持
  • 旧型号产品支持 – 为已停产的模块持续提供服务
保修条款与条件
涵盖项目:
  • 材料和工艺方面的制造缺陷
  • 正常使用下的组件故障
  • 固件或软件问题(提供更新)
  • 文档中的错误或遗漏
除外条款:
  • 错误安装或不当使用
  • 未经授权的修改或维修
  • 事故、误用或疏忽造成的损坏
  • 随时间的正常磨损
重要说明:
  • 所有保修或退货请求均需提供购买凭证
  • 退货时应保留原包装
  • 定制配置或特殊订单产品可能有不同的退货条件
  • 国际运输可能需要考虑额外的处理或运输事项

技术文档

Check out Yokogawa AAI143-S03 Analog Input Module latest technical documentation.

客户评价

发表评论

请通过邮件联系 [email protected] 请通过邮件联系 Follow us on Facebook Subscribe on YouTube