产品介绍 The Yokogawa AAI143-H00 S1 is a high-precision analog input module designed for use within Yokogawas CENTUM and ProSafe-RS Distributed Control Systems (DCS). This module provides

零件号: 1915 有库存
Yokogawa AAI143-H00 S1 Analog Input Module

产品规格

发布时间Jul 07, 2026
制造商 横河
型号 AAI143-H00 S1
零件号 IN1915
状态100% 全新
发货港口中国厦门
交货时间1-3 个工作日
证书COO
快递合作伙伴DHL, UPS, TNT, FedEx and EMS.
保修 1 年
单价
$899.00
USD / 单位
-
+
最小起订量: 1 件
0.0


运输信息
订单满额免运费 $5,000
美国东部时间下午 3 点前下单,当日发货
提供国际运输
Yokogawa AAI143-H00 S1 Analog Input Module Yokogawa AAI143-H00 S1 Analog Input Module Yokogawa AAI143-H00 S1 Analog Input Module Yokogawa AAI143-H00 S1 Analog Input Module

产品介绍

The Yokogawa AAI143-H00 S1 is a high-precision analog input module designed for use within Yokogawa’s CENTUM and ProSafe-RS Distributed Control Systems (DCS). This module provides reliable acquisition and processing / analog signals from field devices, enabling precise measurement and control in critical industrial applications.

The AAI143-H00 S1 is engineered to handle various input types such as voltage, current, and resistance temperature detectors (RTDs). It /fers exceptional accuracy and noise imm件y, contributing to the stable operation / automation systems in sectors including power generation, petrochemicals, and manufacturing.

Its robust construction and Yokogawa’s proven technology ensure long-term durability and consistent performance even under harsh operating conditions.


产品规格

Parameter Specification
Product Name Yokogawa AAI143-H00 S1 Analog Input Module
制造商 横河 Corporation
Product Type Analog Input Module
Compatible Systems CENTUM VP, CENTUM CS 3000, ProSafe-RS
Input Signal Types 4–20 mA, 0–20 mA, 1–5 V, 0–5 V, RTDs, Thermocouples
Number / Channels 8 channels
Input Accuracy ±0.05% / full scale
Conversion Method Delta-Sigma A/D converter
Isolation Channel-to-channel and channel-to-earth isolation
Response Time 100 ms (typical)
Operating Temperature Range 0°C to +55°C
Storage Temperature Range -25°C to +70°C
Humidity 10% to 90% RH, non-condensing
Dimensions (W × H × D) 107.5 × 32.8 × 130 mm
重量 0.3 kg
Power Supply 24 V DC

Applications

The AAI143-H00 S1 Analog Input Module is employed in diverse industries where accurate analog signal acquisition is critical:

  • Power Generation Plants — monitoring critical parameters like temperature, pressure, and flow

  • Petrochemical and Refining Industries — control and safety systems requiring reliable input signals

  • Water and Wastewater Treatment — measuring various process variables for regulatory compliance

  • Chemical Manufacturing — process monitoring and control for reaction conditions

  • Pharmaceutical Production — precise environmental and process condition monitoring

  • Food and Beverage Processing — quality control and process optimization


Advantages

  • High Precision and Stability: With ±0.05% accuracy, the module provides dependable measurement essential for tight process control.

  • Multiple Input Types 支持ed: 支持s various analog signals including current, voltage, thermocouples, and RTDs.

  • Robust Electrical Isolation: Provides channel-to-channel and channel-to-earth isolation to prevent signal interference.

  • Fast Response Time: Typical response time / 100 ms ensures timely data acquisition for process control.

  • Wide Operating Range: Designed to operate reliably within industrial temperature and humidity ranges.

  • Seamless Integration: Compatible with multiple Yokogawa DCS platforms ensuring flexible deployment.

  • Compact and Durable Design: Optimized size and rugged construction for ease / installation and longevity.


常见问题 (FAQ)

  1. What types / analog signals can the AAI143-H00 S1 module handle?
    It supports 4–20 mA, 0–20 mA, 1–5 V, 0–5 V, RTDs, and thermocouples.

  2. How many input channels are available on this module?
    The module provides 8 independent analog input channels.

  3. What is the typical accuracy / the module?
    It /fers ±0.05% full-scale accuracy for precise measurements.

  4. Can the module isolate signals between channels?
    Yes, it provides both channel-to-channel and channel-to-earth electrical isolation.

  5. What is the operating temperature range / the module?
    It operates between 0°C and +55°C reliably.

  6. Is the module compatible with multiple Yokogawa DCS systems?
    Yes, it works with CENTUM VP, CENTUM CS 3000, and ProSafe-RS systems.

  7. What kind / A/D converter does the module use?
    It uses a Delta-Sigma analog-to-digital converter for accurate signal conversion.

  8. What is the typical response time for signal updates?
    The typical response time is around 100 milliseconds.

  9. How is power supplied to the module?
    It uses a 24 V DC power supply.

  10. What are the physical dimensions and weight / the module?
    It measures 107.5 × 32.8 × 130 mm and weighs 0.3 kg.


Related 型号s or Similar Analog Input Modules

型号 描述 Key Features
AAI142-H00 Analog Input Module with 4 Channels 支持s similar signal types, fewer channels
AAI144-H00 High Accuracy Analog Input Module Enhanced precision for critical measurements
AAI145-H00 Analog Input Module with Additional Input Types 支持s thermocouples and RTDs with advanced features
AAI143-H10 Analog Input Module with Extended Temperature Range Wider operating temperature for harsh environments
AAI143-H00 S2 Improved version with faster response time 50 ms typical response time
AAI146-H00 Multi-function Analog Input Module 支持s current, voltage, RTDs, thermocouples

Popular Yokogawa Modules in the Same 品牌

型号 描述 Primary Use
AAI143-H00 Analog Input Module General purpose analog input
AOI143-H00 Analog Output Module Provides analog outputs for control signals
DCI143-H00 Digital Input Module Handles digital input signals
DCO143-H00 Digital Output Module Controls digital output devices
ESD200 Emergency Shutdown System Controller Safety system controller
CENTUM VP PM Process Manager Module Core CPU module in CENTUM VP DCS

公司信息

E-mail: [email protected]

Mobile:请通过邮件联系

Whatsapp:请通过邮件联系

Add: 中国福建省厦门市思明区吕岭路2号阿里山大厦,邮编:361006

我们的服务

我们专业提供工业自动化零部件,并附有一年质保。我们的工业自动化零部件销往全球。

我们能提供来自不同国家和制造商的设备及备件,解决您在多处的顾虑或质量问题,并具有极大的价格优势。

欢迎来电咨询更多产品详情。

产品保修与客户保障

保修详情
  • 2 年标准保修 – 涵盖材料和工艺缺陷
  • 可选延长保修 – 将保修期延长至 5 年
  • 现场技术支持 – 提供经过工厂培训的工程师服务
  • 更换计划 – 48 小时内优先更换
  • 持续的技术协助 – 所有产品的终身支持
质量合规
  • 100% 测试与验证 – 每件产品发货前均经过检查
  • ISO 9001 认证 – 遵守质量管理体系
  • 环境合规 – 符合 RoHS 和 CE 标准
  • 全球安全认证 – UL、cUL 及其他适用认证
  • 可追溯生产 – 完整的序列号和批次可追溯性
退换货政策
  • 30 天退货期 – 未使用产品的退款
  • 无补货费 – 退货处理不收取额外费用
  • 免费退货运费 – 针对有缺陷或错误的商品
  • 交叉发货支持 – 在更换期间最大限度地减少停机时间
  • 简单的 RMA 流程 – 提供在线退货授权
客户权益与支持
  • 价格匹配保证 – 30 天产品价格保护
  • 预留库存 – 为回头客提供优先库存
  • 技术培训 – 提供在线和现场产品培训课程
  • 集成协助 – 为 PLC/DCS 集成提供工程支持
  • 旧型号产品支持 – 为已停产的模块持续提供服务
保修条款与条件
涵盖项目:
  • 材料和工艺方面的制造缺陷
  • 正常使用下的组件故障
  • 固件或软件问题(提供更新)
  • 文档中的错误或遗漏
除外条款:
  • 错误安装或不当使用
  • 未经授权的修改或维修
  • 事故、误用或疏忽造成的损坏
  • 随时间的正常磨损
重要说明:
  • 所有保修或退货请求均需提供购买凭证
  • 退货时应保留原包装
  • 定制配置或特殊订单产品可能有不同的退货条件
  • 国际运输可能需要考虑额外的处理或运输事项

技术文档

Check out Yokogawa AAI143-H00 S1 Analog Input Module latest technical documentation.

客户评价

发表评论

请通过邮件联系 [email protected] 请通过邮件联系 Follow us on Facebook Subscribe on YouTube