产品介绍 The Honeywell TKIXL061 (also known as TCIXL061) is a sixchannel thermocouple input module designed for integration into Honeywell TDC3000/Experion and C200 distributed control sys

零件号: 3579
TAGS:
有库存
Honeywell TK-IXL061 Thermocouple Input Module

产品规格

发布时间Jul 07, 2026
制造商 霍尼韦尔
型号 TK-IXL061
零件号 IN3579
状态100% 全新
发货港口中国厦门
交货时间1-3 个工作日
证书COO
快递合作伙伴DHL, UPS, TNT, FedEx and EMS.
保修 1 年
单价
$1,819.00
USD / 单位
-
+
最小起订量: 1 件
0.0


运输信息
订单满额免运费 $5,000
美国东部时间下午 3 点前下单,当日发货
提供国际运输
Honeywell TK-IXL061 Thermocouple Input Module Honeywell TK-IXL061 Thermocouple Input Module Honeywell TK-IXL061 Thermocouple Input Module Honeywell TK-IXL061 Thermocouple Input Module

产品介绍
The Honeywell TK‑IXL061 (also known as TC‑IXL061) is a six‑channel thermocouple input module designed for integration into Honeywell TDC‑3000/Experion and C200 distributed control systems (DCS). With fully isolated inputs and cold‑junction compensation, it accurately reads temperatures from a variety / thermocouple types. Though superseded by the newer TK‑IXL062, the 061 remains in use in many legacy installations requiring reliable thermocouple readings.


产品规格

Parameter Value
Module type Thermocouple input, 6 channels + 1 cold‑junction channel
Part number 96978480 A01 (Rev. B01)
支持ed thermocouples B, E, J, K, R, S, T, N, C
Input voltage range –12 mV to +78 mV (±12 mV to +30 mV for high resolution)
Resolution 16‑bit (≈1.4 µV nominal)
Sampling/update rate 50 ms for all channels
Settling time (<5% FS) <80 ms
Noise rejection CMRR 120 dB @60 Hz / 100 dB @50 Hz; 60 dB normal noise rejection
Isolation voltage 2,546 VDC channel‑to‑channel and to system
Input current 250 mA @5.1 VDC; 125 mA @24 VDC
Operating temperature –40 °C to +85 °C
Storage temperature –40 °C to +100 °C
Humidity 0–95% non‑condensing
Protection class IP65
Dimensions 170 x 80 x 45 mm
重量 0.3 kg
Cold‑junction compensation Yes, using built‑in thermistor (TC‑CJRT01)

Key Applications
• Industrial process control systems (e.g., petrochemical, power, refining, CHP plants)
• Temperature acquisition in DCS/PLC environments
• Retr/itting legacy Honeywell TDC/DCS systems
• Any scenario needing multiple thermocouple readings with galvanic isolation


Advantages
High accuracy: 16‑bit resolution with <80 ms settling ensures precise, reliable readings
Wide TC compatibility: Accepts 9 thermocouple types, /fering universal flexibility
Robust isolation: 2.5 kV isolation ensures electrical safety and minimal crosstalk
Strong noise imm件y: 优秀 CMRR and rejection / normal-mode noise
Environment-resistant: Operates in harsh conditions from –40 °C to +85 °C; rated IP65
Seamless integration: Plug‑and‑play module for Honeywell racks; drop-in replacement
Cold-junction compensation: Embedded thermistor ensures accurate temperature references


常见问题 (FAQs)

  1. Q: Is TK‑IXL061 compatible with newer Honeywell systems?
    A: It works seamlessly in legacy TDC‑3000/C200/Experion systems; newer systems may require TK‑IXL062.

  2. Q: What are the supported thermocouple types?
    A: 支持s B, E, J, K, R, S, T, N, and C thermocouples.

  3. Q: What resolution can I expect?
    A: Offers 16‑bit resolution (~1.4 µV); high‑res mode (~0.7 µV) for low‑range channels.

  4. Q: How fast does it update readings?
    A: All 6 channels refresh every 50 ms.

  5. Q: What environmental conditions can it handle?
    A: –40 °C to +85 °C; 0–95% humidity non‑condensing; rated IP65.

  6. Q: Does it include cold‑junction compensation?
    A: Yes, via internal thermistor (TC‑CJRT01).

  7. Q: How many channels does it support?
    A: Six input channels plus one cold‑junction channel.

  8. Q: What isolation voltage is provided?
    A: 2,546 VDC isolation between channels and to system.

  9. Q: Can I replace it with TK‑IXL062 directly?
    A: Yes, but terminal rewiring is necessary when switching to TK‑IXL062.

  10. Q: What’s its physical weight and size?
    A: 0.3 kg; 170 x 80 x 45 mm.


Related / Same‑Series 型号s

型号 描述
TK‑IXL062 Coated successor to TK‑IXL061
TC‑IXR061 6‑point RTD input module
TK‑IAH061 6‑channel 4–20 mA analog input module
TK‑HAI081 8‑channel HART analog input module
TK‑TAIH02 High‑level analog input FTA, 8 channels
TK‑IXR061 RTD version for resistance temperature devices

Popular Honeywell Modules (Same Family)

型号 Function
TK‑IAH161 16‑channel analog input (4–20 mA/10 V)
TK‑ODD321 32‑point discrete output module (24 VDC)
TK‑OAV061 6‑channel analog output (10 V)
TK‑IDD321 32‑point DC input module (24 VDC)
TK‑ODK161 16‑point AC output module (120/220 VAC, isolated)
TK‑PRS021 Redundant controller processor module (C200 rack)

公司信息

E-mail: [email protected]

Mobile:请通过邮件联系

Whatsapp:请通过邮件联系

Add: 中国福建省厦门市思明区吕岭路2号阿里山大厦,邮编:361006

我们的服务

我们专业提供工业自动化零部件,并附有一年质保。我们的工业自动化零部件销往全球。

我们能提供来自不同国家和制造商的设备及备件,解决您在多处的顾虑或质量问题,并具有极大的价格优势。

欢迎来电咨询更多产品详情。

产品保修与客户保障

保修详情
  • 2 年标准保修 – 涵盖材料和工艺缺陷
  • 可选延长保修 – 将保修期延长至 5 年
  • 现场技术支持 – 提供经过工厂培训的工程师服务
  • 更换计划 – 48 小时内优先更换
  • 持续的技术协助 – 所有产品的终身支持
质量合规
  • 100% 测试与验证 – 每件产品发货前均经过检查
  • ISO 9001 认证 – 遵守质量管理体系
  • 环境合规 – 符合 RoHS 和 CE 标准
  • 全球安全认证 – UL、cUL 及其他适用认证
  • 可追溯生产 – 完整的序列号和批次可追溯性
退换货政策
  • 30 天退货期 – 未使用产品的退款
  • 无补货费 – 退货处理不收取额外费用
  • 免费退货运费 – 针对有缺陷或错误的商品
  • 交叉发货支持 – 在更换期间最大限度地减少停机时间
  • 简单的 RMA 流程 – 提供在线退货授权
客户权益与支持
  • 价格匹配保证 – 30 天产品价格保护
  • 预留库存 – 为回头客提供优先库存
  • 技术培训 – 提供在线和现场产品培训课程
  • 集成协助 – 为 PLC/DCS 集成提供工程支持
  • 旧型号产品支持 – 为已停产的模块持续提供服务
保修条款与条件
涵盖项目:
  • 材料和工艺方面的制造缺陷
  • 正常使用下的组件故障
  • 固件或软件问题(提供更新)
  • 文档中的错误或遗漏
除外条款:
  • 错误安装或不当使用
  • 未经授权的修改或维修
  • 事故、误用或疏忽造成的损坏
  • 随时间的正常磨损
重要说明:
  • 所有保修或退货请求均需提供购买凭证
  • 退货时应保留原包装
  • 定制配置或特殊订单产品可能有不同的退货条件
  • 国际运输可能需要考虑额外的处理或运输事项

技术文档

Check out Honeywell TK-IXL061 Thermocouple Input Module latest technical documentation.

客户评价

发表评论

请通过邮件联系 [email protected] 请通过邮件联系 Follow us on Facebook Subscribe on YouTube