Product 描述
The Honeywell RM7890A1015 is a microprocessor-based integrated burner control designed for automatically fired gas, oil, or combination fuel single burner applications. It ensures safe and reliable operation by controlling the burner sequencing, flame supervision, diagnostics, and status indication.
Technical Specifications
| Parameter | Value |
|---|---|
| Operating Voltage | 120 Vac (+10% / -15%), 50/60 Hz |
| Power Dissipation | Max. 10 W |
| Ambient Operating Temp | -40°F to +140°F (-40°C to +60°C) |
| Storage Temperature | -40°F to +150°F (-40°C to +66°C) |
| Humidity | 85% RH continuous, non-condensing |
| Dimensions | 127 x 127 x 133 mm |
| 重量 | 0.83 kg |
| Maximum Connected Load | 2000 VA, 15A fuse maximum |
| Vibration Resistance | 0.5G environment |
| Certifications | UL listed, CSA certified, FM approved |
Applications
-
Industrial boilers
-
Commercial heating systems
-
Power plant burners
-
Gas and oil-fired furnaces
-
Single burner systems requiring flame monitoring and safety interlocks
Advantages
-
Integrated microprocessor for precise control
-
Extensive safety checks including dynamic logic and flame system self-tests
-
Retains history and fault data even after power loss
-
Modular design with optional communication and display modules
-
Field-proven reliability and long service life
-
Simple installation and maintenance
常见问题 (FAQ)
Q1: What type / burners is RM7890A1015 compatible with?
A1: It is compatible with automatically fired gas, oil, or combination fuel single burner systems.
Q2: Can it operate at low ambient temperatures?
A2: Yes, it operates reliably down to -40°C.
Q3: Does it retain fault history after a power outage?
A3: Yes, its non-volatile memory stores history and status data.
Q4: What is the maximum electrical load it supports?
A4: It supports up to 2000 VA with a maximum 15A fuse.
Q5: Is a remote reset function available?
A5: Yes, remote reset is supported as an optional feature.
Q6: What optional accessories can be used?
A6: Keyboard display modules, network interfaces, remote displays, and annunciators are available.
Q7: How is flame detection achieved?
A7: It uses plug-in flame signal amplifiers and compatible detectors such as UV, IR, or flame rods.
Q8: What mounting options are available?
A8: It can be mounted using Q7800A for panels or Q7800B for wall/burner mounts.
Q9: Is it certified for use in Canada?
A9: Yes, it is CSA certified for Canadian markets.
Q10: What is the weight / the 件?
A10: The RM7890A1015 weighs approximately 0.83 kg.
Recommended Related or Similar 型号s
| 型号 | 描述 | Dimensions (mm) | 重量 (kg) |
|---|---|---|---|
| RM7890B1013 | Burner Control, similar logic | 127 x 127 x 133 | 0.83 |
| RM7890C1000 | Burner Control, standing pilot | 127 x 127 x 133 | 0.83 |
| EC7890A1029 | Burner Control, 220-240 Vac | 127 x 127 x 133 | 0.83 |
| EC7890B1028 | Burner Control, 220-240 Vac | 127 x 127 x 133 | 0.83 |
| RM7800L1075 | Expanded annunciator model | 127 x 127 x 133 | 0.83 |
| RM7800G1001 | Standard burner controller | 127 x 127 x 133 | 0.83 |
Popular Honeywell 型号s
| 型号 | 描述 | Dimensions (mm) | 重量 (kg) |
|---|---|---|---|
| RM7800L1075 | Expanded annunciator burner control | 127 x 127 x 133 | 0.83 |
| RM7800G1001 | Burner control, standard version | 127 x 127 x 133 | 0.83 |
| R7847A1033 | Ultraviolet flame amplifier | 127 x 127 x 133 | 0.83 |
| R7861A1026 | Ultraviolet flame amplifier | 127 x 127 x 133 | 0.83 |
| RM7895A1014 | Primary burner controller | 127 x 127 x 133 | 0.83 |
| RM7885A1008 | Programmable relay module | 127 x 127 x 133 | 0.83 |
公司信息
E-mail: [email protected]
Mobile:请通过邮件联系
Whatsapp:请通过邮件联系
Add: 中国福建省厦门市思明区吕岭路2号阿里山大厦,邮编:361006
我们的服务
我们专业提供工业自动化零部件,并附有一年质保。我们的工业自动化零部件销往全球。
我们能提供来自不同国家和制造商的设备及备件,解决您在多处的顾虑或质量问题,并具有极大的价格优势。
欢迎来电咨询更多产品详情。