The HIMA F3226 is a 2-channel safety-related switching amplifier module, designed to meet the demanding safety requirements / critical industrial automation systems. As part / HIMA’s high-integrity safety controller systems, the F3226 ensures reliable and fault-tolerant signal amplification for binary input devices such as mechanical switches, proximity sensors, or optical sensors. It is widely used in applications where safety and availability are / utmost importance, especially in industries such as oil and gas, chemical processing, power generation, and transportation infrastructure.
This module is developed and certified according to IEC 61508 and EN 50156-2 standards, achieving SIL 3 levels / safety integrity when used within approved system architectures. The HIMA F3226 ensures that the integrity / safety-critical signals is maintained even in harsh industrial environments.
产品规格
| Parameter | Value |
|---|---|
| Product Name | F3226 2-Channel Safety Switching Amplifier |
| 制造商 | HIMA Paul Hildebrandt GmbH |
| Function | Switching Amplifier Module for Safety Systems |
| Number / Channels | 2 (independently isolated channels) |
| Input Signal Type | Binary input (mechanical, inductive, optical) |
| Output Type | Optocoupler-based switching output |
| Safety Integrity Level | SIL 3 (according to IEC 61508) |
| Response Time | < 5 ms |
| Isolation | Galvanic isolation between input and output |
| Power Supply | 24 V DC ±10% |
| Power Consumption | Approx. 1.5 W |
| Operating Temperature | -20°C to +60°C |
| Storage Temperature | -40°C to +85°C |
| Mounting | DIN Rail |
| Dimensions (H x W x D) | 193 x 117 x 40 mm |
| 重量 | 0.168 kg |
| Certifications | IEC 61508, EN 50156, CE, SIL 3 |
Product Applications
The F3226 is ideally suited for applications involving critical safety signal monitoring and amplification in:
-
Emergency shutdown systems (ESD)
-
Burner control and boiler protection systems
-
Turbine control and safety interlock systems
-
Pipeline and compressor station automation
-
Chemical and petrochemical plant safety loops
-
Power plant turbine and generator protection circuits
Its robust design and certification for SIL 3 make it a preferred choice for ensuring continuous, fault-tolerant signal integrity in safety-instrumented systems (SIS).
Product Advantages
-
High Safety Integrity: Certified up to SIL 3 according to IEC 61508 for use in the most demanding safety systems.
-
Dual-Channel Architecture: Offers independent channel operation with fault tolerance and redundancy.
-
Robust Isolation: Galvanic isolation between inputs and outputs prevents fault propagation and electrical noise interference.
-
Compact Design: Narrow module width allows for space-saving DIN rail installations in dense control cabinets.
-
Low Power Consumption: Energy-efficient design reduces heat buildup and enhances system longevity.
-
High Compatibility: Can interface with a wide range / mechanical and electronic sensors and actuators.
-
Fail-Safe Behavior: Designed to default to a safe state in the event / internal fault detection.
-
Simple Maintenance: Hot-swappable design and clear diagnostics support fast replacement and low downtime.
-
Global Standards Compliance: Meets international norms for functional safety and industrial reliability.
-
Long-Term Availability: HIMA ensures long product life cycles and backward compatibility.
常见问题 (FAQ)
-
What is the main function / the HIMA F3226 module?
It serves as a 2-channel safety-related amplifier to process binary input signals from field devices in safety-critical applications. -
Which standards does the F3226 comply with?
It complies with IEC 61508, EN 50156, and other relevant safety standards up to SIL 3. -
What types / input devices can it handle?
It can interface with mechanical switches, proximity sensors, inductive sensors, and optical signal devices. -
Can I use F3226 in non-safety systems?
Yes, but it is optimized for safety-related functions where high reliability is required. -
Does it support hot swapping?
Yes, the F3226 supports hot swapping for easy maintenance and minimal downtime. -
Is the module compatible with HIMA’s HIMax or HIQuad platforms?
Yes, it integrates seamlessly with both HIMax and HIQuad safety systems. -
What is the power supply requirement?
It requires a 24 V DC power supply, with a tolerance / ±10%. -
Can this module be installed in outdoor environments?
It must be installed in a protected cabinet. It is rated for -20°C to +60°C ambient temperatures. -
What diagnostic functions are available?
The module includes self-monitoring and fault diagnostic features accessible via the system controller. -
How fast is the response time from input activation to output switching?
The typical response time is less than 5 milliseconds, which is suitable for real-time safety-critical applications such as ESD (Emergency Shutdown) and burner management systems.
Recommended Related 型号s (Same Series or Similar Function)
| 型号 Number | 描述 | Channels | SIL Level | Input Type |
|---|---|---|---|---|
| F3227 | 2-channel switching amplifier with extended diagnostics | 2 | SIL 3 | Binary |
| F3236 | 2-channel high-speed input amplifier module | 2 | SIL 3 | Fast binary |
| F3330 | 2-channel digital input module for safety applications | 2 | SIL 3 | Digital |
| F3237 | 2-channel input/output hybrid module | 2 | SIL 3 | Binary I/O |
| F8621A | Analog output module for critical loop control | N/A | SIL 2 | Analog output |
| F7553 | 16-channel digital input module | 16 | SIL 3 | Digital input |
Recommended Popular HIMA 型号s (Same 品牌)
| 型号 Number | 描述 | Application Area | SIL Level |
|---|---|---|---|
| F8650E | CPU module for HIMax safety system | Central processing | SIL 3 |
| F8621A | Analog output module | Process control | SIL 2 |
| F7133 | 16-channel relay output module | General control applications | SIL 3 |
| F8652X | Communication module for redundant systems | Communication backbone | SIL 3 |
| F8640 | Universal input module | Versatile field input | SIL 3 |
| F7126 | 8-channel analog input module | Analog signal processing | SIL 2 |
公司信息
E-mail: [email protected]
Mobile:请通过邮件联系
Whatsapp:请通过邮件联系
Add: 中国福建省厦门市思明区吕岭路2号阿里山大厦,邮编:361006
我们的服务
我们专业提供工业自动化零部件,并附有一年质保。我们的工业自动化零部件销往全球。
我们能提供来自不同国家和制造商的设备及备件,解决您在多处的顾虑或质量问题,并具有极大的价格优势。
欢迎来电咨询更多产品详情。