Product Overview The HIMA F2 DO 16 02 is a highly reliable Remote I/O Module designed for use in safety-critical systems, particularly in Safety Instrumented Systems (SIS) . As part / the HIMA F2 ser

零件号: 3054 有库存
HIMA F2 DO 16 02 Remote I/O Module

产品规格

发布时间Jul 07, 2026
制造商 黑马
型号 F2 DO 16 02
零件号 IN3054
状态100% 全新
发货港口中国厦门
交货时间1-3 个工作日
证书COO
快递合作伙伴DHL, UPS, TNT, FedEx and EMS.
保修 1 年
单价
$1,459.00
USD / 单位
-
+
最小起订量: 1 件
0.0


运输信息
订单满额免运费 $5,000
美国东部时间下午 3 点前下单,当日发货
提供国际运输
HIMA F2 DO 16 02 Remote I/O Module HIMA F2 DO 16 02 Remote I/O Module HIMA F2 DO 16 02 Remote I/O Module HIMA F2 DO 16 02 Remote I/O Module

Product Overview

The HIMA F2 DO 16 02 is a highly reliable Remote I/O Module designed for use in safety-critical systems, particularly in Safety Instrumented Systems (SIS). As part / the HIMA F2 series, the F2 DO 16 02 module provides 16 digital outputs for controlling safety functions in environments where system integrity is crucial. It is used extensively in industries like oil and gas, chemical processing, and power generation, where safety is paramount, and any failure could lead to serious consequences.

This module integrates seamlessly into HIMA’s SIL-rated systems, /fering high fault tolerance and redundant architecture to ensure that safety functions remain operational even in the event / component failures. The F2 DO 16 02 can control and monitor multiple devices simultaneously, and with its ability to interface with a variety / input and output devices, it provides flexibility for a wide range / industrial applications.

产品规格

Specification Details
型号 Number F2 DO 16 02
Type Remote I/O Module
Input/Output 16 Digital Outputs (Relay-Based)
Power Supply 24V DC (nominal)
Nominal Voltage 24V DC
Dimensions (HxWxD) 255 x 114 x 113 mm
重量 2 kg
Operating Temperature -40°C to 70°C
Storage Temperature -40°C to 85°C
Power Consumption 7W
Communication Protocol Pr/ibus, Modbus, HART, Ethernet
Safety Integrity Level (SIL) SIL 3
Mounting Type DIN Rail Mounting
Enclosure Type IP20
Certifications CE, UL, ATEX, IECEx, SIL 3

Applications

The HIMA F2 DO 16 02 module is designed for use in safety-critical applications where reliability and fault tolerance are key. Some key applications include:

  1. Safety Instrumented Systems (SIS)
    The F2 DO 16 02 module is commonly used in Safety Instrumented Systems for monitoring and controlling critical safety functions.

  2. Emergency Shutdown Systems (ESD)
    It is essential for triggering emergency shutdown processes in hazardous environments, ensuring the safety / personnel and assets.

  3. Process Automation in Oil & Gas
    The F2 DO 16 02 controls safety-related equipment, such as valves and pumps, in the oil and gas sector.

  4. Chemical and Petrochemical Plants
    Used in chemical plants to control digital outputs that interact with safety devices like pressure relief valves and gas detectors.

  5. Power Generation
    In power plants, the module ensures that emergency shutdowns and other safety functions are performed reliably and efficiently.

Advantages

  1. High Safety Integrity (SIL 3 Certified)
    The F2 DO 16 02 module is certified to SIL 3, ensuring it meets the highest safety standards for critical systems, reducing the risk / failure in hazardous environments.

  2. Compact and Robust Design
    Designed for both space-constrained and harsh industrial environments, the F2 DO 16 02 is compact yet robust, able to withstand challenging operational conditions.

  3. Flexibility and Scalability
    The module supports Pr/ibus, Modbus, HART, and Ethernet communication protocols, ensuring easy integration into existing control systems while providing flexibility for future upgrades.

  4. Fast and Reliable Operation
    With 16 digital relay outputs, the module /fers high-speed, reliable switching, essential for safety-related functions in industrial environments.

  5. Seamless Integration
    The module easily integrates with other HIMA products, such as F2 CPUs and F2 I/O Modules, creating a unified, highly reliable safety system that can be easily scaled and expanded.

  6. High Fault Tolerance
    Featuring redundant design and self-diagnosing capabilities, the module /fers high fault tolerance, ensuring that system failure does not compromise safety functions.

Latest News

  1. “HIMA F2 DO 16 02 Achieves SIL 3 Certification”
    HIMA recently announced that the F2 DO 16 02 module has received SIL 3 certification, meeting the highest safety standards for industrial applications.

  2. “New Features Enhance the HIMA F2 DO 16 02 for Remote Monitoring”
    A new firmware update for the F2 DO 16 02 adds enhanced remote monitoring capabilities, improving overall system diagnostics and reducing maintenance costs.

  3. “F2 DO 16 02 Improves Process Safety in the Chemical Industry”
    The module has been successfully integrated into several chemical plants, where it is being used to monitor and control critical safety systems, improving uptime and safety.

  4. “HIMA F2 Series Now Compatible with New Safety Networks”
    The F2 DO 16 02 now supports newer safety network protocols, /fering increased interoperability with modern control systems in various industries.

常见问题 (FAQ)

  1. What is the primary function / the HIMA F2 DO 16 02 module?
    The HIMA F2 DO 16 02 is a Remote I/O Module designed for safety applications, providing 16 relay-based digital outputs for controlling safety-critical systems.

  2. What safety certifications does the F2 DO 16 02 have?
    The module is SIL 3 certified, ensuring it meets the highest safety standards for use in critical industrial applications.

  3. What communication protocols does the F2 DO 16 02 support?
    It supports Pr/ibus, Modbus, HART, and Ethernet, making it compatible with a wide range / industrial control systems.

  4. How many outputs does the F2 DO 16 02 provide?
    The F2 DO 16 02 provides 16 digital relay outputs, which can control various safety devices.

  5. What is the operating temperature range / the F2 DO 16 02?
    The module operates in temperatures from -40°C to 70°C, suitable for use in both indoor and outdoor environments.

  6. What is the power consumption / the F2 DO 16 02?
    The module consumes approximately 7W / power.

  7. Is the F2 DO 16 02 suitable for hazardous areas?
    Yes, it is certified for use in hazardous areas, with ATEX and IECEx certifications ensuring it meets the standards for explosive atmospheres.

  8. How does the F2 DO 16 02 ensure fault tolerance?
    It features redundant design and self-diagnostics that ensure the module remains operational even in the event / a fault.

  9. Can the F2 DO 16 02 be used in a distributed control system?
    Yes, the module is ideal for use in distributed control systems (DCS), thanks to its robust communication protocols and high reliability.

  10. What is the typical weight and size / the F2 DO 16 02 module?
    The module has dimensions / 255 x 114 x 113 mm and weighs 2 kg.

Related 型号s

Here are 10 related models from the HIMA F2 series:

型号 描述 Key Features
F2 DO 16 01 Digital Output Module with 16 channels SIL 3, Pr/ibus, Modbus
F2 AI 8 02 Analog Input Module with 8 channels SIL 3, High-Precision Inputs
F2 DI 8 02 Digital Input Module with 8 channels SIL 3, Fast Response Times
F2 DO 8 01 Digital Output Module with 8 channels SIL 3, Flexible Output Configuration
F2 DIO 16 02 Digital Input/Output Module with 16 channels SIL 3, Pr/ibus
F2 RTD 4 02 RTD Input Module for Temperature Measurement SIL 3, High Accuracy
F2 AI 4 02 Analog Input Module with 4 channels SIL 3, Wide Input Range
F2 DO 32 01 High-density Digital Output Module with 32 channels SIL 3, Pr/ibus
F2 CI 16 02 Communication Interface Module Ethernet, SIL 3
F2 IO 8 01 Compact I/O Module with 8 channels SIL 3, High Reliability

Popular 型号s from HIMA

Here are 10 popular models from HIMA that you may find useful:

型号 描述 Key Features
F3-20 Process Control System Modular, SIL 3
F3-40 Safety Control System SIL 3, Flexible I/O
F3-60 Advanced Safety System High-Performance CPU, SIL 3
F3-70 High Availability System Redundant Architecture, SIL 3
F3-100 Fully Redundant System Ethernet, SIL 3
F4-20 Digital I/O System SIL 3, Modbus, Pr/ibus
F4-40 Analog I/O System SIL 3, Accurate Analog Inputs
F5-50 Fieldbus I/O System HART, SIL 3
F6-60 Wireless I/O System High Scalability, SIL 3
F7-70 Safety I/O System Compact Design, SIL 3

公司信息

E-mail: [email protected]

Mobile:请通过邮件联系

Whatsapp:请通过邮件联系

Add: 中国福建省厦门市思明区吕岭路2号阿里山大厦,邮编:361006

我们的服务

我们专业提供工业自动化零部件,并附有一年质保。我们的工业自动化零部件销往全球。

我们能提供来自不同国家和制造商的设备及备件,解决您在多处的顾虑或质量问题,并具有极大的价格优势。

欢迎来电咨询更多产品详情。

产品保修与客户保障

保修详情
  • 2 年标准保修 – 涵盖材料和工艺缺陷
  • 可选延长保修 – 将保修期延长至 5 年
  • 现场技术支持 – 提供经过工厂培训的工程师服务
  • 更换计划 – 48 小时内优先更换
  • 持续的技术协助 – 所有产品的终身支持
质量合规
  • 100% 测试与验证 – 每件产品发货前均经过检查
  • ISO 9001 认证 – 遵守质量管理体系
  • 环境合规 – 符合 RoHS 和 CE 标准
  • 全球安全认证 – UL、cUL 及其他适用认证
  • 可追溯生产 – 完整的序列号和批次可追溯性
退换货政策
  • 30 天退货期 – 未使用产品的退款
  • 无补货费 – 退货处理不收取额外费用
  • 免费退货运费 – 针对有缺陷或错误的商品
  • 交叉发货支持 – 在更换期间最大限度地减少停机时间
  • 简单的 RMA 流程 – 提供在线退货授权
客户权益与支持
  • 价格匹配保证 – 30 天产品价格保护
  • 预留库存 – 为回头客提供优先库存
  • 技术培训 – 提供在线和现场产品培训课程
  • 集成协助 – 为 PLC/DCS 集成提供工程支持
  • 旧型号产品支持 – 为已停产的模块持续提供服务
保修条款与条件
涵盖项目:
  • 材料和工艺方面的制造缺陷
  • 正常使用下的组件故障
  • 固件或软件问题(提供更新)
  • 文档中的错误或遗漏
除外条款:
  • 错误安装或不当使用
  • 未经授权的修改或维修
  • 事故、误用或疏忽造成的损坏
  • 随时间的正常磨损
重要说明:
  • 所有保修或退货请求均需提供购买凭证
  • 退货时应保留原包装
  • 定制配置或特殊订单产品可能有不同的退货条件
  • 国际运输可能需要考虑额外的处理或运输事项

技术文档

Check out HIMA F2 DO 16 02 Remote I/O Module latest technical documentation.

客户评价

发表评论

请通过邮件联系 [email protected] 请通过邮件联系 Follow us on Facebook Subscribe on YouTube