报价 (0)

ABB ZINT-792+N8205 3AXD50000030405 MC Interface Board

ProductOverview The ABBZINT792+N8205 MC Interface Board (order code3AXD50000030405) is engineered as a highperformance multichannel communication core for ABB automation platforms. It links programmab

零件号: 8793 有库存
ABB ZINT-792+N8205 3AXD50000030405 MC Interface Board

产品规格

发布时间Jul 08, 2026
制造商 ABB PLC
型号 ZINT-792+N8205 3AXD50000030405
零件号 IN8793
状态100% 全新
发货港口中国厦门
交货时间1-3 个工作日
证书COO
快递合作伙伴DHL, UPS, TNT, FedEx and EMS.
保修 1 年
单价
$1,819.00
USD / 单位
-
+
最小起订量: 1 件
0.0


运输信息
订单满额免运费 $5,000
美国东部时间下午 3 点前下单,当日发货
提供国际运输
ABB ZINT-792+N8205 3AXD50000030405 MC Interface Board ABB ZINT-792+N8205 3AXD50000030405 MC Interface Board ABB ZINT-792+N8205 3AXD50000030405 MC Interface Board ABB ZINT-792+N8205 3AXD50000030405 MC Interface Board

Product Overview

The ABB ZINT‑792+N8205 MC Interface Board (order code 3AXD50000030405) is engineered as a high‑performance multichannel communication core for ABB automation platforms. It links programmable logic controllers, drives, HMIs, and third‑party field devices, guaranteeing deterministic data flow even in electrically noisy plant environments. Rigorously tested to IEC 61000‑6‑2/4 standards, it withstands voltage surges, ESD, and radiated RF without communication loss. A conformally coated PCB and industrial‑grade components extend mean‑time‑between‑failure well beyond 150 000 h. The board drops directly onto a 35 mm DIN rail, drawing minimal power from the 24 VDC control bus—ideal for retr/it projects where cabinet space and power budgets are tight.


Product Specifications

Parameter Specification
型号 ZINT‑792+N8205
Order Code 3AXD50000030405
Interface Type MC (Multichannel) Interface
支持ed Protocols Modbus RTU (2‑wire RS‑485), CANopen DS‑301, ABB DriveBus
Baud‑Rate Range 9.6 kbit/s – 1 Mbit/s (auto‑negotiation)
Galvanic Isolation 2.5 kV DC between field and logic domains
Input Voltage 24 VDC ± 15 %
Inrush Current < 5 A, 10 ms
Steady Current 0.5 A (typ.)
Dimensions 235 × 145 × 30 mm
重量 0.4 kg
Mounting 35 mm DIN rail, tool‑free clip
Operating Temp. –20 °C to +60 °C
Storage Temp. –40 °C to +85 °C
Humidity 5 % – 95 % RH, non‑condensing
Vibration 5 g, 10 Hz – 150 Hz, IEC 60068‑2‑6
Firmware Update Field‑loadable via micro‑USB (DFU mode)

Applications

  • Distributed Control Systems (DCS) – Integrates remote I/O islands with central process controllers over long RS‑485 trunks.

  • Drive Chains – Provides deterministic command/feedback loops between ACS/ACS‑S drives and plant PLCs, enabling speed and torque coordination.

  • Machine Tools – Bridges high‑speed CANopen motion networks with legacy Modbus diagnostics for spindle and axis modules.

  • Energy Management – Aggregates data from smart meters and power analyzers, forwarding key KPIs to SCADA dashboards in real time.

  • Building Automation – Acts as a protocol gateway between HVAC controllers, lighting panels, and security systems, reducing gateway counts.

  • Lab & Test Rigs – Offers galvanic isolation and surge imm件y critical for precision measurement devices in EMC‑heavy test cells.


Product Advantages

  • Multi‑Protocol on One PCB – Handles Modbus, CANopen, and ABB DriveBus simultaneously; no extra gateway modules required.

  • Robust Isolation – 2.5 kV isolation safeguards PLC CPU boards from field transients and ground loops.

  • Field‑Upgradeable Firmware – DFU utility delivers bug fixes and feature upgrades without removing the board.

  • Compact Footprint – 30 mm thickness leaves airflow channels free inside crowded cabinets.

  • Low Power Draw – < 12 W typical, easing load on 24 VDC power supplies and UPS systems.

  • Extended Life Design – Conformal coating plus 105 °C electrolytic capacitors push service life beyond 15 years in 45 °C ambient.

  • Tool‑Free Installation – Spring‑lock DIN clip and pluggable terminals cut installation time by 40 %.

  • Diagnostic LEDs – Per‑channel status LEDs simplify troubleshooting, reducing downtime.

  • EMC‑Hardened – Meets Class A limits; passes 10 V/m radiated imm件y—ideal for drives rooms.

  • Global Compliance – CE, UKCA, cULus Recognition, RCM‑Australia certified for worldwide deployment.


FAQ

  1. What cabling should I use for RS‑485 lines?
    Use 2‑conductor shielded twisted pair, 120 Ω characteristic impedance, AWG 22 – 24.

  2. Is hot‑swap permitted?
    Yes, the board supports live insertion on powered 24 VDC buses; communications resume within 3 s.

  3. Can I mix CANopen and Modbus devices simultaneously?
    Absolutely—the MCU allocates independent buffers and time slices for each protocol stack.

  4. How do I update firmware?
    Connect a PC via micro‑USB, launch ABB DFU‑Suite, select the *.bin file, and press “Flash”; typical load time < 90 s.

  5. Does the board log diagnostics?
    Yes, a 64‑entry circular fault log is accessible through the Modbus holding register range 0x3000–0x303F.

  6. What is the idle power consumption?
    9 W at 24 VDC with all channels enabled but no traffic.

  7. Are termination resistors integrated?
    Each RS‑485 segment has switchable 120 Ω termination accessible on the terminal header.

  8. What enclosure rating is required?
    Mount inside a minimum IP20 enclosure; no forced cooling needed below 50 °C ambient.

  9. How many nodes can one board manage?
    Up to 64 Modbus slaves and 127 CANopen devices concurrently.

  10. Is a conformity certificate available?
    CE Declaration / Conformity is downloadable from the ABB product page; hard copy ships with each 件.


Recommended 型号s — Same Series / Related

型号 描述 Dimensions 重量
ZINT‑790+N8205 Entry‑level MC board with Modbus only 235 × 145 × 30 mm 0.38 kg
ZINT‑791+N8206 CANopen‑focused variant with higher isolation 235 × 145 × 30 mm 0.39 kg
ZINT‑792+N8206 Dual‑protocol board with extended temp range to +70 °C 235 × 145 × 30 mm 0.42 kg
ZINT‑793+N8205 High‑speed MC board, 2 Mbit/s Modbus option 235 × 145 × 30 mm 0.41 kg
ZINT‑794+N8204 Smart‑diagnostics MC board with onboard web server 235 × 145 × 30 mm 0.44 kg
ZINT‑795+N8205 Redundant‑channel MC board for SIL2 systems 235 × 145 × 30 mm 0.45 kg

Popular ABB Automation 型号s

型号 描述 重量
ZINT-571 Standard MC interface board, supports multiple I/O types, compatible with N8205 0.660 kg
ZINT-592 High-speed interface module, designed for redundant communication paths 0.680 kg
ZINT-511 Communication interface board, 2-channel, standard update rate 0.610 kg
ZINT-541 EMI-resistant interface module, extended I/O isolation features 0.650 kg
ZINT-521 Compact interface board for cabinet space optimization 0.600 kg
ZINT-7B1C MC interface module, wide protocol support, industrial-grade reliability 0.630 kg

公司信息

E-mail: [email protected]

Mobile:请通过邮件联系

Whatsapp:请通过邮件联系

Add: 中国福建省厦门市思明区吕岭路2号阿里山大厦,邮编:361006

我们的服务

我们专业提供工业自动化零部件,并附有一年质保。我们的工业自动化零部件销往全球。

我们能提供来自不同国家和制造商的设备及备件,解决您在多处的顾虑或质量问题,并具有极大的价格优势。

欢迎来电咨询更多产品详情。

产品保修与客户保障

保修详情
  • 2 年标准保修 – 涵盖材料和工艺缺陷
  • 可选延长保修 – 将保修期延长至 5 年
  • 现场技术支持 – 提供经过工厂培训的工程师服务
  • 更换计划 – 48 小时内优先更换
  • 持续的技术协助 – 所有产品的终身支持
质量合规
  • 100% 测试与验证 – 每件产品发货前均经过检查
  • ISO 9001 认证 – 遵守质量管理体系
  • 环境合规 – 符合 RoHS 和 CE 标准
  • 全球安全认证 – UL、cUL 及其他适用认证
  • 可追溯生产 – 完整的序列号和批次可追溯性
退换货政策
  • 30 天退货期 – 未使用产品的退款
  • 无补货费 – 退货处理不收取额外费用
  • 免费退货运费 – 针对有缺陷或错误的商品
  • 交叉发货支持 – 在更换期间最大限度地减少停机时间
  • 简单的 RMA 流程 – 提供在线退货授权
客户权益与支持
  • 价格匹配保证 – 30 天产品价格保护
  • 预留库存 – 为回头客提供优先库存
  • 技术培训 – 提供在线和现场产品培训课程
  • 集成协助 – 为 PLC/DCS 集成提供工程支持
  • 旧型号产品支持 – 为已停产的模块持续提供服务
保修条款与条件
涵盖项目:
  • 材料和工艺方面的制造缺陷
  • 正常使用下的组件故障
  • 固件或软件问题(提供更新)
  • 文档中的错误或遗漏
除外条款:
  • 错误安装或不当使用
  • 未经授权的修改或维修
  • 事故、误用或疏忽造成的损坏
  • 随时间的正常磨损
重要说明:
  • 所有保修或退货请求均需提供购买凭证
  • 退货时应保留原包装
  • 定制配置或特殊订单产品可能有不同的退货条件
  • 国际运输可能需要考虑额外的处理或运输事项

技术文档

Check out ABB ZINT-792+N8205 3AXD50000030405 MC Interface Board latest technical documentation.

客户评价

发表评论

请通过邮件联系 [email protected] 请通过邮件联系 Follow us on Facebook Subscribe on YouTube