見積もり (0)

Yokogawa NFAI141-S00 Analog Input Module

製品紹介 The Yokogawa NFAI141-S00 Analog Input Module is an advanced industrial-grade component designed to deliver high-precision analog signal acquisition in process automation systems.

品番: 1406 在庫あり
Yokogawa NFAI141-S00 Analog Input Module

製品仕様

発売時期Jul 07, 2026
メーカー 横河電機
モデル NFAI141-S00
型番 IN1406
状態100%新品
出荷港中国廈門
リードタイム1-3営業日
認証COO
配送パートナーDHL, UPS, TNT, FedEx and EMS.
保証 1年間
単価
$1,369.00
USD / ユニット
-
+
最小注文: 1 台
0.0


配送情報
一定金額以上のご注文で送料無料 $5,000
東部標準時午後3時までのご注文は当日発送いたします。
国際配送可能
Yokogawa NFAI141-S00 Analog Input Module Yokogawa NFAI141-S00 Analog Input Module Yokogawa NFAI141-S00 Analog Input Module Yokogawa NFAI141-S00 Analog Input Module

製品紹介

The Yokogawa NFAI141-S00 Analog Input Module is an advanced industrial-grade component designed to deliver high-precision analog signal acquisition in process automation systems. Engineered for integration into Yokogawa’s high-reliability control platforms, this module provides accurate, stable, and noise-resistant measurement for a wide range / industrial applications. Its superior design ensures seamless operation even in harsh environments, making it an essential component in critical control systems across energy, chemical, oil & gas, and manufacturing industries.

The NFAI141-S00 module supports multiple signal types, enabling flexibility for different process requirements. Its robust isolation design minimizes interference, while its self-diagnostic capabilities enhance operational safety and reliability. This module is ideally suited for tasks requiring fast, accurate, and continuous data acquisition in real-time process control.


Product Parameters

Parameter Specification
モデル NFAI141-S00
Type Analog Input Module
Input Channels 16 channels
Signal Type Voltage / Current
Input Range -10 V to +10 V or 4-20 mA
Resolution 16-bit
Isolation Channel-to-channel and channel-to-ground
Sampling Time Approx. 5 ms per channel
Accuracy ±0.1% / full scale
Power Supply 24 VDC
Operating Temperature 0°C to 55°C
Storage Temperature -20°C to 70°C
Dimensions 130 x 107.5 x 32.8 mm
重量 0.2 kg
Mounting DIN Rail / Baseplate
Communication Interface Yokogawa Proprietary System Bus

Product Applications

The NFAI141-S00 module plays a critical role in process control and monitoring, providing accurate analog signal input for various industries. Its primary application areas include:

  • Process Automation: Captures continuous measurements from sensors to ensure precise control / industrial processes.

  • Oil & Gas: Monitors flow rates, pressures, and temperatures in pipelines and refineries for safe operation.

  • Power Generation: Collects analog signals from turbines and generators to optimize energy output and efficiency.

  • Chemical Processing: Maintains strict process control by monitoring temperature, pressure, and chemical reaction rates.

  • Water Treatment: Gathers data from sensors for quality monitoring and automated control systems.

  • Pharmaceutical Manufacturing: サポートs compliance with stringent quality standards through precise environmental monitoring.


Product Advantages

  • High Accuracy and Stability: Ensures precise measurement with 16-bit resolution, minimizing process errors.

  • Comprehensive Signal サポート: Compatible with voltage and current signals, allowing flexibility for diverse applications.

  • Robust Electrical Isolation: Provides channel-to-channel isolation to reduce noise and prevent signal interference.

  • Enhanced Reliability: Designed for industrial environments with strong resistance to electromagnetic interference (EMI).

  • Integrated Diagnostics: Features built-in self-check mechanisms to detect faults quickly and improve system uptime.

  • Easy Integration: Seamlessly integrates with Yokogawa control platforms, reducing engineering and setup time.

  • Compact Design: Space-efficient module that fits into tight control panel configurations.


FAQ

  1. What type / signals can the NFAI141-S00 module process?
    It supports both voltage and current signals, such as ±10 V for voltage input and 4–20 mA for current input.

  2. How does the module maintain measurement accuracy under temperature variations?
    The module uses temperature-compensated circuitry to ensure accuracy even under fluctuating environmental conditions.

  3. Does the module support simultaneous input signal acquisition?
    Yes, the module uses high-speed multiplexing and sampling to achieve near-simultaneous acquisition across multiple channels.

  4. What isolation method does the NFAI141-S00 use?
    It utilizes opto-isolation for each channel to protect against electrical surges and reduce signal interference.

  5. What is the default sampling rate / the analog input channels?
    The default sampling rate is approximately 5 milliseconds per channel, suitable for real-time control applications.

  6. Can the module detect wiring errors or sensor failures?
    Yes, it includes diagnostic features to identify open circuits, short circuits, and abnormal input conditions.

  7. What filtering techniques are implemented to minimize signal noise?
    The module uses digital filtering and low-pass filtering to reduce high-frequency noise and provide clean analog data.

  8. How does the module handle redundant configurations?
    It supports redundant system architecture, allowing primary and backup modules for critical process reliability.

  9. Is calibration required for the module, and how is it performed?
    Periodic calibration is recommended and can be performed via Yokogawa’s engineering tools without removing the module from the system.

  10. What communication protocol does the module use to interface with the control system?
    It communicates via Yokogawa’s proprietary system bus, ensuring high-speed, secure, and stable data transmission.


Related モデルs (Same Series or Similar Functionality)

モデル Number 説明
NFAI141-H00 Standard Analog Input Module (16 CH)
NFAI141-S00 Enhanced Analog Input Module
NFAO141-H00 Analog Output Module
NFDI143-H00 Digital Input Module
NFDO145-H00 Digital Output Module
NFVI150-H00 Voltage Input Module

Popular Yokogawa モデルs

モデル Number 説明
AIP827-320 High-Performance Analog Input Processor
NFAF135-S50 S1 Frequency Input Module
SAI143 Signal Cable for Analog Interface
NFDO145-H00 High-Density Digital Output Module
NFAI135-H00 High-Resolution Analog Input Module
SAI533 Isolated Signal Interface Cable

会社情報

E-mail: [email protected]

Mobile:メールでのお問い合わせ

Whatsapp:メールでのお問い合わせ

Add: 中国福建省廈門市思明区呂嶺路2号 阿里山ビル 〒361006

サービス内容

当社は産業用オートメーション部品の供給を専門としており、1年間の保証を提供しております。当社の産業用オートメーション部品は世界中に販売されています。

当社は様々な国やメーカーの機器及びスペアパーツを提供し、複数拠点でのご不安や品質問題を解消するとともに、大きな価格メリットを実現しております。

製品詳細については、お気軽にお電話にてお問い合わせください。

製品保証とお客様サポート

保証詳細
  • 2年間標準保証 – 材料および製造上の欠陥をカバー
  • オプション延長保証 – 最大5年まで延長可能
  • オンサイト技術サポート – 工場トレーニングを受けたエンジニアが対応
  • 交換プログラム – 48時間以内の優先交換
  • 継続的技術支援 – 全製品のライフタイムサポート
品質コンプライアンス
  • 100%テスト済み・検証済み – 出荷前に各ユニットを検査
  • ISO 9001認証取得 – 品質マネジメントシステム準拠
  • 環境コンプライアンス – RoHSおよびCE基準準拠
  • 国際安全認証 – UL、cUL、その他該当する認証
  • トレーサブル生産 – 完全なシリアルおよびバッチ追跡
返品・交換ポリシー
  • 30日間返品期間 – 未使用製品の返金
  • 再入庫手数料なし – 追加料金なしで返品処理
  • 返品送料無料 – 不良品または誤品の場合
  • 交換品先行発送 – 交換中のダウンタイムを最小化
  • 簡単RMA手続き – オンライン返品承認が可能
お客様の権利とサポート
  • プライスマッチ保証 – 30日間の製品価格保護
  • 優先在庫確保 – リピーター様向け優先在庫
  • 技術トレーニング – オンラインおよびオンサイトでの製品トレーニング
  • 統合支援 – PLC/DCS統合のエンジニアリングサポート
  • レガシー製品サポート – 製造中止モジュールの継続サービス
保証規約
保証対象:
  • 材料および製造上の欠陥
  • 通常使用下での部品故障
  • ファームウェアまたはソフトウェアの問題(アップデート提供)
  • ドキュメントの誤りまたは欠落
保証除外事項:
  • 誤った設置または不適切な使用
  • 無許可の改造または修理
  • 事故、誤用、または不注意による損傷
  • 経年による通常の摩耗
重要事項:
  • すべての保証または返品リクエストには購入証明が必要です
  • 返品の際は元の梱包材を保管してください
  • カスタム設定品または特注品は異なる返品条件が適用される場合があります
  • 国際配送には追加の手続きや配送条件が適用される場合があります

技術文書

Check out Yokogawa NFAI141-S00 Analog Input Module latest technical documentation.

お客様のレビュー

レビューを投稿

メールでのお問い合わせ [email protected] メールでのお問い合わせ Follow us on Facebook Subscribe on YouTube