見積もり (0)

Yokogawa AAV144-S53/K4A00 Voltage Input Module

製品紹介 The Yokogawa AAV144-S53/K4A00 is a high-performance Voltage Input Module designed specifically for integration with Yokogawas CENTUM CS 3000 and CENTUM VP distributed control syst

品番: 1821 在庫あり
Yokogawa AAV144-S53/K4A00 Voltage Input Module

製品仕様

発売時期Jul 07, 2026
メーカー 横河電機
モデル AAV144-S53/K4A00
型番 IN1821
状態100%新品
出荷港中国廈門
リードタイム1-3営業日
認証COO
配送パートナーDHL, UPS, TNT, FedEx and EMS.
保証 1年間
単価
$709.00
USD / ユニット
-
+
最小注文: 1 台
0.0


配送情報
一定金額以上のご注文で送料無料 $5,000
東部標準時午後3時までのご注文は当日発送いたします。
国際配送可能
Yokogawa AAV144-S53/K4A00 Voltage Input Module Yokogawa AAV144-S53/K4A00 Voltage Input Module Yokogawa AAV144-S53/K4A00 Voltage Input Module Yokogawa AAV144-S53/K4A00 Voltage Input Module

製品紹介

The Yokogawa AAV144-S53/K4A00 is a high-performance Voltage Input Module designed specifically for integration with Yokogawa’s CENTUM CS 3000 and CENTUM VP distributed control systems (DCS). As part / the Analog Input Module family, this model excels in monitoring DC voltage signals, delivering precision analog measurements for complex industrial automation systems. Its robust configuration allows for enhanced signal fidelity, low-noise performance, and high imm台y to electrical interference, making it a reliable component for critical process applications.

Developed with long-term reliability and operational continuity in mind, the AAV144-S53/K4A00 supports a wide range / analog voltage signals and is capable / isolating input signals to prevent system-wide disruptions. It is especially tailored for industries requiring strict analog performance, such as power generation, petrochemical, oil and gas, and pharmaceuticals.


製品仕様

Parameter 説明
モデル Number AAV144-S53/K4A00
Product Type Voltage Input Module
メーカー 横河電機 Corporation
Input Channels 16 channels (isolated per channel)
Input Signal Range ±10V DC (can be configured)
Input Impedance ≥10 MΩ
Resolution 16-bit A/D conversion
Accuracy ±0.1% / full scale
Isolation 1000 V AC between input and system
Conversion Time 50 ms per channel
Power Supply Supplied through the I/O base plate
Diagnostic Function Open wire detection, Input signal failure detection
Redundancy サポート Yes (with redundant systems)
Operating Temperature Range 0 to 50°C
Storage Temperature Range -20 to 70°C
Humidity 5% to 95% RH (non-condensing)
Mounting Mounted on I/O base 台
Dimensions (W x H x D) 107.5 × 130 × 32.8 mm
重量 0.2 kg
Applicable Systems CENTUM CS 3000, CENTUM VP
Certification CE, UL, CSA compliant

Product Applications

  • Oil & Gas: Monitoring / field instruments and control signals in refineries and pipelines.

  • Power Plants: Voltage sensing for turbine control and electrical distribution systems.

  • Pharmaceuticals: Recording cleanroom sensor data with high accuracy.

  • Chemical Processing: Handling analog process variables with minimized signal distortion.

  • Water Treatment: Accurate measurement / control voltages in dosing and filtration systems.

  • Pulp and Paper: Integration into distributed control networks for energy and quality control.


Product Advantages

  • High Signal Accuracy: With 16-bit resolution and low error tolerance, it ensures accurate analog input readings.

  • Input Isolation: Each input channel is isolated, enhancing safety and preventing cross-interference.

  • Advanced Diagnostics: Equipped with failure detection features to support proactive maintenance.

  • System Compatibility: Seamlessly integrates into Yokogawa’s flagship DCS platforms.

  • Reduced Downtime: サポートs redundancy configurations to maintain system availability.

  • Space Efficient Design: Compact module suitable for high-density I/O cabinets.

  • Electromagnetic Imm台y: 優良 performance in noisy industrial environments.

  • Extended Temperature Range: Reliable operation even in demanding environmental conditions.

  • Compliant with Global Standards: CE, UL, CSA certifications ensure worldwide deployment capabilities.

  • Long-Term サポート: Backed by Yokogawa’s extensive service and upgrade lifecycle management.


FAQ

  1. Does the AAV144-S53/K4A00 support multi-range input signal configuration?
    Yes, it supports configuration for various DC voltage ranges including ±10V, ±5V, and 0–10V.

  2. Can this module detect input signal faults or wiring issues automatically?
    Yes, it includes open wire and signal failure detection functions.

  3. What is the A/D conversion precision / this module?
    The AAV144-S53/K4A00 uses 16-bit A/D conversion for high resolution.

  4. Is hot-swapping supported for this module?
    No, hot-swapping is not supported. Modules must be installed or removed when the system is powered down.

  5. Does this module provide channel-to-channel isolation?
    Yes, each input channel is galvanically isolated from the others.

  6. Can the module be calibrated via the control system?
    Yes, it supports s/tware-based calibration through Yokogawa’s engineering tools.

  7. What diagnostic functions are integrated in the module?
    It includes diagnostics for open circuit detection, signal level fault, and hardware failure.

  8. Does it support redundant I/O configurations?
    Yes, it is compatible with redundant I/O configurations to enhance system reliability.

  9. What is the default sampling time per channel?
    The default analog sampling time is 50 milliseconds per channel.

  10. How does the module handle overvoltage protection?
    Built-in protection circuitry prevents damage from transient input voltage spikes.


Related モデルs from the Same Series

モデル 説明 Signal Type Channels System Compatibility
AAV141-S50 Analog Input Module (Voltage) Voltage 16 CENTUM VP, CS 3000
AAV142-S00 Voltage Input Module (Isolated) Voltage 16 CENTUM VP
AAV143-S03 High-Speed Analog Input Module Voltage 8 CENTUM CS 3000
AAP135-S00 Analog Output Module Voltage/Current 8 CENTUM CS 3000
ADV151-P03 Digital Input Module Discrete 32 CENTUM VP, CS 3000
AAI141-H50 High Voltage Analog Input Module Voltage 16 CENTUM VP

Popular Yokogawa Modules

モデル 説明 Function System Compatibility Channels
AAI141-S50 Analog Input Module Analog Input CENTUM VP, CS 3000 16
AAI543-S00 Analog Output Module Analog Output CENTUM VP, CS 3000 8
ADV151-P03 Digital Input Module Digital Input CENTUM VP, CS 3000 32
ADV561-P00 Digital Output Module Digital Output CENTUM VP, CS 3000 32
AAR181-S00 RTD Input Module Temperature Sensing CENTUM VP 8
AAM50 Power Supply Module Power Supply FCS Cabinet

会社情報

E-mail: [email protected]

Mobile:メールでのお問い合わせ

Whatsapp:メールでのお問い合わせ

Add: 中国福建省廈門市思明区呂嶺路2号 阿里山ビル 〒361006

サービス内容

当社は産業用オートメーション部品の供給を専門としており、1年間の保証を提供しております。当社の産業用オートメーション部品は世界中に販売されています。

当社は様々な国やメーカーの機器及びスペアパーツを提供し、複数拠点でのご不安や品質問題を解消するとともに、大きな価格メリットを実現しております。

製品詳細については、お気軽にお電話にてお問い合わせください。

製品保証とお客様サポート

保証詳細
  • 2年間標準保証 – 材料および製造上の欠陥をカバー
  • オプション延長保証 – 最大5年まで延長可能
  • オンサイト技術サポート – 工場トレーニングを受けたエンジニアが対応
  • 交換プログラム – 48時間以内の優先交換
  • 継続的技術支援 – 全製品のライフタイムサポート
品質コンプライアンス
  • 100%テスト済み・検証済み – 出荷前に各ユニットを検査
  • ISO 9001認証取得 – 品質マネジメントシステム準拠
  • 環境コンプライアンス – RoHSおよびCE基準準拠
  • 国際安全認証 – UL、cUL、その他該当する認証
  • トレーサブル生産 – 完全なシリアルおよびバッチ追跡
返品・交換ポリシー
  • 30日間返品期間 – 未使用製品の返金
  • 再入庫手数料なし – 追加料金なしで返品処理
  • 返品送料無料 – 不良品または誤品の場合
  • 交換品先行発送 – 交換中のダウンタイムを最小化
  • 簡単RMA手続き – オンライン返品承認が可能
お客様の権利とサポート
  • プライスマッチ保証 – 30日間の製品価格保護
  • 優先在庫確保 – リピーター様向け優先在庫
  • 技術トレーニング – オンラインおよびオンサイトでの製品トレーニング
  • 統合支援 – PLC/DCS統合のエンジニアリングサポート
  • レガシー製品サポート – 製造中止モジュールの継続サービス
保証規約
保証対象:
  • 材料および製造上の欠陥
  • 通常使用下での部品故障
  • ファームウェアまたはソフトウェアの問題(アップデート提供)
  • ドキュメントの誤りまたは欠落
保証除外事項:
  • 誤った設置または不適切な使用
  • 無許可の改造または修理
  • 事故、誤用、または不注意による損傷
  • 経年による通常の摩耗
重要事項:
  • すべての保証または返品リクエストには購入証明が必要です
  • 返品の際は元の梱包材を保管してください
  • カスタム設定品または特注品は異なる返品条件が適用される場合があります
  • 国際配送には追加の手続きや配送条件が適用される場合があります

技術文書

Check out Yokogawa AAV144-S53/K4A00 Voltage Input Module latest technical documentation.

お客様のレビュー

レビューを投稿

メールでのお問い合わせ [email protected] メールでのお問い合わせ Follow us on Facebook Subscribe on YouTube