Yokogawa AAR181-S00 S2 RTD Input Module

製品紹介 The Yokogawa AAR181-S00 S2 is a high-performance 8-channel RTD input module, engineered to deliver accurate and stable resistance temperature detection within distributed control

品番: 2339 在庫あり
Yokogawa AAR181-S00 S2 RTD Input Module

製品仕様

発売時期Jul 07, 2026
メーカー 横河電機
モデル AAR181-S00 S2
型番 IN2339
状態100%新品
出荷港中国廈門
リードタイム1-3営業日
認証COO
配送パートナーDHL, UPS, TNT, FedEx and EMS.
保証 1年間
単価
$1,359.00
USD / ユニット
-
+
最小注文: 1 台
0.0


配送情報
一定金額以上のご注文で送料無料 $5,000
東部標準時午後3時までのご注文は当日発送いたします。
国際配送可能
Yokogawa AAR181-S00 S2 RTD Input Module Yokogawa AAR181-S00 S2 RTD Input Module Yokogawa AAR181-S00 S2 RTD Input Module Yokogawa AAR181-S00 S2 RTD Input Module

製品紹介

The Yokogawa AAR181-S00 S2 is a high-performance 8-channel RTD input module, engineered to deliver accurate and stable resistance temperature detection within distributed control systems. As part / Yokogawa’s field-proven I/O family, this module is specifically built to interface with RTD sensors like Pt100, JPt100, and others, ensuring highly accurate temperature measurements across various industrial applications.

With its advanced signal isolation, robust architecture, and high channel resolution, the AAR181-S00 S2 supports reliable operation in demanding process environments such as power generation, chemical plants, and oil & gas refineries. The “S2” revision denotes an updated firmware/hardware set with enhanced reliability and extended system compatibility.


製品仕様

Parameter Specification
モデル AAR181-S00 S2
説明 8-Channel RTD Input Module
Input Type RTD (Pt100, JPt100, Cu10, Cu53, etc.)
Number / Channels 8 isolated input channels
Measurement Range -200°C to +850°C (depends on sensor type)
Input Resolution 16-bit
Accuracy ±0.1% / full scale (typical)
Input Impedance High impedance (>1 MΩ)
Channel Isolation Isolated channel-to-channel and from system ground
Sampling Cycle 100 ms (typical)
Interface For use with Yokogawa’s N-IO or FIO terminal base
Power Supply Supplied via I/O base 台
Operating Temperature -20°C to 70°C
Storage Temperature -40°C to 85°C
Humidity 5% to 95% RH (non-condensing)
Dimensions 107.5 × 130 × 32.8 mm
重量 0.2 kg
Mounting Method Terminal base mounting (rack-based installation)
Compliance & Certifications CE, RoHS, KC, ISA Standards Compliant

Product Applications

The AAR181-S00 S2 is ideal for precision temperature monitoring and control in the following industries:

  • Power Plants: For temperature monitoring / turbine shafts, bearings, and heat exchangers.

  • Oil & Gas Facilities: Used in distillation columns, compressor stations, and safety-critical temperature monitoring.

  • Chemical Manufacturing: Critical for controlling temperature-sensitive reaction vessels and storage tanks.

  • Pharmaceuticals: Ensures GMP-compliant temperature data in cleanroom and sterilization environments.

  • Food & Beverage: Maintains quality and safety in cooking, pasteurization, and fermentation processes.

  • Water Treatment: Tracks environmental conditions and equipment temperature for optimized operations.


Product Advantages

  • High Accuracy: Ensures precise temperature measurement, improving process control quality and reducing waste.

  • Channel Isolation: Prevents electrical interference, allowing stable multi-point measurement.

  • Scalable Integration: Easily integrated into Yokogawa DCS systems for centralized monitoring and control.

  • Flexible Sensor Compatibility: サポートs multiple RTD types with customizable range settings.

  • Robust Industrial Design: Operates reliably in harsh conditions including temperature fluctuations and high humidity.

  • Reduced Downtime: Built-in diagnostics and fault detection minimize troubleshooting time.

  • Compact Footprint: High channel density in a small module saves control cabinet space.

  • Firmware Stability (S2): Enhanced s/tware version ensures reliable long-term operation with Yokogawa’s latest DCS platforms.


よくある質問 (FAQ)

  1. What RTD sensor types can be connected to the AAR181-S00 S2?
    The module supports Pt100, JPt100, Cu10, and Cu53 RTDs, among others.

  2. How many RTD sensors can be connected simultaneously?
    The module supports up to 8 RTD sensors, one per channel.

  3. Is this module compatible with CENTUM VP?
    Yes, it is fully compatible with Yokogawa CENTUM VP and ProSafe-RS systems.

  4. What does the “S2” suffix indicate?
    It indicates a second-generation or updated version / the module, with firmware and reliability improvements.

  5. Can this module detect sensor disconnection?
    Yes, open-circuit detection is supported, and it will generate system alarms for operator action.

  6. Does the module /fer hot-swapping?
    番号 For safety and system integrity, modules should be inserted or removed only with power /f.

  7. What is the default scan interval?
    The default scan time is typically 100 milliseconds.

  8. Is field calibration required?
    Factory calibration is generally sufficient, though users may perform periodic verification.

  9. How is the wiring configured for 3-wire or 4-wire RTD sensors?
    The terminal base supports standard 3-wire or 4-wire configurations with proper terminal mapping.

  10. Does it support redundant operation?
    Yes, when installed within a Yokogawa redundant I/O system, the module supports fault-tolerant configuration.


Recommended Related モデルs (Same Series or Function)

モデル 説明
AAR181-S01 RTD Input Module with enhanced diagnostics
AAR145-S00 16-Channel RTD/POT Input Module
AAR145-S50 High-accuracy RTD/POT Input Module
AAR841-S00 High-speed RTD Module for critical applications
AAI143-H00 16-Channel Analog Input Module
AAR111-S00 8-Channel Universal Analog Input Module

Popular Yokogawa モデルs (Same ブランド, Different Functionality)

モデル 説明
AAI543-H00 High-density Analog Output Module
CP451-10 Main Processor Module for CENTUM VP
ADV151-P00 FOUNDATION Fieldbus Communication Module
SAI533-H00 Safety-Certified Analog Input Module
AAI143-H50 General Purpose Analog Input Module (16 Channels)
PW402 Redundant Power Supply Module for Control System Racks

会社情報

E-mail: [email protected]

Mobile:メールでのお問い合わせ

Whatsapp:メールでのお問い合わせ

Add: 中国福建省廈門市思明区呂嶺路2号 阿里山ビル 〒361006

サービス内容

当社は産業用オートメーション部品の供給を専門としており、1年間の保証を提供しております。当社の産業用オートメーション部品は世界中に販売されています。

当社は様々な国やメーカーの機器及びスペアパーツを提供し、複数拠点でのご不安や品質問題を解消するとともに、大きな価格メリットを実現しております。

製品詳細については、お気軽にお電話にてお問い合わせください。

製品保証とお客様サポート

保証詳細
  • 2年間標準保証 – 材料および製造上の欠陥をカバー
  • オプション延長保証 – 最大5年まで延長可能
  • オンサイト技術サポート – 工場トレーニングを受けたエンジニアが対応
  • 交換プログラム – 48時間以内の優先交換
  • 継続的技術支援 – 全製品のライフタイムサポート
品質コンプライアンス
  • 100%テスト済み・検証済み – 出荷前に各ユニットを検査
  • ISO 9001認証取得 – 品質マネジメントシステム準拠
  • 環境コンプライアンス – RoHSおよびCE基準準拠
  • 国際安全認証 – UL、cUL、その他該当する認証
  • トレーサブル生産 – 完全なシリアルおよびバッチ追跡
返品・交換ポリシー
  • 30日間返品期間 – 未使用製品の返金
  • 再入庫手数料なし – 追加料金なしで返品処理
  • 返品送料無料 – 不良品または誤品の場合
  • 交換品先行発送 – 交換中のダウンタイムを最小化
  • 簡単RMA手続き – オンライン返品承認が可能
お客様の権利とサポート
  • プライスマッチ保証 – 30日間の製品価格保護
  • 優先在庫確保 – リピーター様向け優先在庫
  • 技術トレーニング – オンラインおよびオンサイトでの製品トレーニング
  • 統合支援 – PLC/DCS統合のエンジニアリングサポート
  • レガシー製品サポート – 製造中止モジュールの継続サービス
保証規約
保証対象:
  • 材料および製造上の欠陥
  • 通常使用下での部品故障
  • ファームウェアまたはソフトウェアの問題(アップデート提供)
  • ドキュメントの誤りまたは欠落
保証除外事項:
  • 誤った設置または不適切な使用
  • 無許可の改造または修理
  • 事故、誤用、または不注意による損傷
  • 経年による通常の摩耗
重要事項:
  • すべての保証または返品リクエストには購入証明が必要です
  • 返品の際は元の梱包材を保管してください
  • カスタム設定品または特注品は異なる返品条件が適用される場合があります
  • 国際配送には追加の手続きや配送条件が適用される場合があります

技術文書

Check out Yokogawa AAR181-S00 S2 RTD Input Module latest technical documentation.

お客様のレビュー

レビューを投稿

メールでのお問い合わせ [email protected] メールでのお問い合わせ Follow us on Facebook Subscribe on YouTube