The Woodward LR20949 Measuring Transducer is a precision industrial device designed to convert analog or mechanical signals into standardized electrical outputs for monitoring, control, and feedback purposes. Engineered for high-reliability applications, this transducer provides accurate measurement / parameters such as speed, position, pressure, or torque depending on system configuration. The LR20949 is widely used in power generation, engine control, and process automation systems, where precise measurement is critical for maintaining operational stability and safety. Its robust design ensures consistent performance under harsh environmental conditions, making it suitable for industrial, marine, and energy applications.
Product Parameters
| Parameter | Specification |
|---|---|
| Product Type | Measuring Transducer |
| モデル | LR20949 |
| Dimensions | 130 × 80 × 50 mm |
| 重量 | 0.45 kg |
| Input Signal | Analog or mechanical input (voltage, current, or displacement-based) |
| Output Signal | Standardized electrical output (4–20 mA or 0–10 V DC) |
| Power Supply | 24 V DC nominal |
| Power Consumption | 3–5 W typical |
| Operating Temperature Range | –20 °C to +70 °C |
| Storage Temperature Range | –40 °C to +85 °C |
| Accuracy | ±0.2 % full scale |
| Response Time | <10 ms |
| Isolation | Galvanic isolation between input and output |
| Mounting | Panel or DIN rail mountable |
| Housing Material | Aluminum with protective coating |
| Environmental Protection | IP65 |
Applications
The LR20949 Measuring Transducer is designed for accurate signal conversion and measurement in industrial systems, including:
-
Engine and Generator Control – monitoring speed, torque, and position for precise control and protection.
-
Power Generation Plants – feeding accurate measurement signals to control systems for load balancing and monitoring.
-
Industrial Automation – providing feedback signals to PLCs and SCADA systems.
-
Marine and Offshore Equipment – high-reliability measurement under harsh marine environments.
-
Process Control Systems – converting mechanical or analog process signals into standardized electrical outputs for centralized monitoring.
Its high accuracy and rapid response make it ideal for critical systems where precise feedback is essential to maintain operational efficiency and safety.
Advantages
-
High Accuracy and Precision: ±0.2 % full-scale accuracy ensures reliable measurements.
-
Fast Response Time: Less than 10 ms response time supports dynamic systems with rapidly changing inputs.
-
Robust Industrial Design: Aluminum housing with IP65 protection resists dust, moisture, and harsh industrial environments.
-
Flexible Mounting Options: Can be mounted on panels or DIN rails, supporting varied installation needs.
-
Wide Operating Range: Maintains performance from –20 °C to +70 °C.
-
Galvanic Isolation: Input and output signals are isolated to prevent interference and ground loops.
-
Standardized Output Signals: Compatible with 4–20 mA and 0–10 V DC systems.
-
Energy Efficient: Low power consumption makes it suitable for distributed measurement systems.
FAQ
-
What types / input signals can the LR20949 measure?
It can measure analog voltage, current, or mechanical displacement depending on configuration. -
What is the standard output signal / this transducer?
Standard outputs are 4–20 mA or 0–10 V DC for integration with control systems. -
What is the accuracy / the LR20949?
The device provides ±0.2 % full-scale accuracy over its operating range. -
How fast is the response time / the transducer?
Response time is less than 10 ms, suitable for dynamic feedback applications. -
Can the transducer operate in harsh industrial environments?
Yes, its aluminum housing and IP65 rating protect against dust, moisture, and mechanical stress. -
What is the operating temperature range for reliable performance?
The transducer operates reliably from –20 °C to +70 °C. -
Is there isolation between input and output signals?
Yes, galvanic isolation prevents interference and ground loop issues. -
How is the LR20949 mounted in industrial systems?
It supports panel or DIN rail mounting for flexible installation. -
What power supply is required for this module?
A 24 V DC nominal supply is required, with typical consumption / 3–5 W. -
Can this transducer be integrated with PLCs or SCADA systems?
Yes, the standardized 4–20 mA or 0–10 V output allows seamless integration with industrial control systems.
Recommended Related モデルs (Same Series or Compatible)
| モデル | 説明 |
|---|---|
| LR20940 | Basic measuring transducer for speed and torque signals |
| LR20941 | High-accuracy analog-to-electrical signal transducer |
| LR20942 | Fast-response transducer for dynamic measurement |
| LR20943 | Marine-grade measuring transducer with corrosion resistance |
| LR20944 | Load and position transducer for industrial engines |
| LR20945 | Multi-input measuring transducer for process applications |
Popular Woodward モデルs (Same ブランド)
| モデル | 説明 |
|---|---|
| SST-PB3 | Engine control module for distributed power systems |
| MRD1T2HTL6M42 | Digital speed control module for engines and generators |
| 8440 | Digital speed controller for industrial engines |
| 2301 | Actuation and feedback control module |
| 5050 | Industrial governor interface |
| 5350 | Modular control system for hybrid power applications |
会社情報
E-mail: [email protected]
Mobile:メールでのお問い合わせ
Whatsapp:メールでのお問い合わせ
Add: 中国福建省廈門市思明区呂嶺路2号 阿里山ビル 〒361006
サービス内容
当社は産業用オートメーション部品の供給を専門としており、1年間の保証を提供しております。当社の産業用オートメーション部品は世界中に販売されています。
当社は様々な国やメーカーの機器及びスペアパーツを提供し、複数拠点でのご不安や品質問題を解消するとともに、大きな価格メリットを実現しております。
製品詳細については、お気軽にお電話にてお問い合わせください。