見積もり (0)

Woodward 5441-691 Relay Field Terminal Module

製品紹介 The Woodward 5441-691 Relay Field Terminal Module is a high-performance interface component designed for reliable relay control and signal routing in industrial automation systems

品番: 6352
TAGS:
在庫あり
Woodward 5441-691 Relay Field Terminal Module

製品仕様

発売時期Jul 08, 2026
メーカー Woodward
モデル 5441-691
型番 IN6352
状態100%新品
出荷港中国廈門
リードタイム1-3営業日
認証COO
配送パートナーDHL, UPS, TNT, FedEx and EMS.
保証 1年間
単価
$1,709.00
USD / ユニット
-
+
最小注文: 1 台
0.0


配送情報
一定金額以上のご注文で送料無料 $5,000
東部標準時午後3時までのご注文は当日発送いたします。
国際配送可能
Woodward 5441-691 Relay Field Terminal Module Woodward 5441-691 Relay Field Terminal Module Woodward 5441-691 Relay Field Terminal Module Woodward 5441-691 Relay Field Terminal Module

製品紹介

The Woodward 5441-691 Relay Field Terminal Module is a high-performance interface component designed for reliable relay control and signal routing in industrial automation systems. Engineered to provide secure field wiring connections, this module simplifies the integration / control signals between Woodward controllers and field devices such as relays, actuators, and sensors. Its robust construction and optimized PCB layout ensure dependable operation in environments where electrical noise, vibration, and temperature fluctuations are common. The module /fers clear terminal labeling and rugged screw connections, making installation and maintenance efficient even in complex control cabinets.


Technical Specifications

Parameter Details
モデル Number 5441-691
メーカー Woodward
Function Relay field terminal interface module
Input Voltage Range 18–32 VDC nominal
Relay Output Type Form C (SPDT) contacts
お問い合わせ Rating 5 A at 250 VAC / 30 VDC
Isolation 1500 V RMS between control and field circuits
Operating Temperature -40 °C to +85 °C
Storage Temperature -55 °C to +105 °C
Humidity Tolerance 5%–95% non-condensing
Mounting Method DIN-rail or panel-mount
Termination Type Screw-clamp removable terminal blocks
Dimensions (W × H × D) 150 × 110 × 40 mm
重量 0.45 kg
Standards Compliance CE, UL recognized, RoHS compliant

Applications

  • Turbine and Generator Control: Provides field termination for relays controlling turbines, compressors, and generators in power plants.

  • Industrial Automation: Interfaces programmable logic controllers (PLCs) with external devices requiring isolated relay contacts.

  • Oil & Gas Facilities: Handles critical control signals in drilling rigs and pipeline stations where high reliability is essential.

  • Marine and Transportation Systems: Ensures robust relay control in ship propulsion systems and heavy-duty locomotives.

  • Process Control Plants: Connects sensors, alarms, and control circuits for chemical, pharmaceutical, or food-processing equipment.


Advantages

  • High Electrical Isolation: 1500 V RMS isolation between control and field circuits minimizes the risk / noise coupling and equipment damage.

  • Flexible Mounting Options: サポートs both DIN-rail and panel-mounting for easy integration into new or existing control cabinets.

  • Robust Relay Output: SPDT relay contacts with 5 A rating provide reliable switching for a variety / loads.

  • User-Friendly Wiring: Removable screw-clamp terminal blocks simplify field connections and maintenance.

  • Industrial-Grade Durability: Wide temperature range and vibration resistance ensure consistent performance in harsh environments.

  • Global Compliance: Meets CE, UL, and RoHS standards for worldwide acceptance in critical industrial applications.


FAQ

  1. What type / relay outputs does the 5441-691 module provide?
    It provides Form C (single-pole, double-throw) relay outputs, allowing both normally open and normally closed contact configurations to suit various control needs.

  2. How does the module achieve isolation between the control circuit and field wiring?
    Galvanic isolation rated at 1500 V RMS is integrated into the design, effectively protecting control electronics from transient voltages and electrical noise.

  3. Can the relay contacts handle inductive loads such as solenoids or motors?
    Yes, but it is recommended to use proper snubber or flyback suppression components to protect the contacts and maintain long-term reliability.

  4. Is the module compatible with standard 24 VDC control systems?
    Absolutely. Its 18–32 VDC operating range makes it suitable for typical 24 VDC industrial control applications.

  5. What is the recommended tightening torque for the terminal screws?
    The terminal blocks are designed for a torque / approximately 0.5–0.6 Nm, ensuring secure connections without damaging the conductor or terminal.

  6. Does the module require an external power supply for the relay coils?
    Yes, an external 24 VDC supply within the specified range is required to energize the relay coils and power the internal circuitry.

  7. How does the module handle high inrush currents at the relay contacts?
    The relay contacts are rated for 5 A continuous and can tolerate moderate inrush currents; external surge protection is recommended for very high inrush loads.

  8. Can the module be mounted horizontally as well as vertically?
    Yes, it can be mounted in any orientation as long as there is adequate ventilation and the wiring is properly secured.

  9. What diagnostic indicators are provided on the board?
    Integrated LED indicators show relay status and power supply presence, facilitating quick troubleshooting during commissioning and maintenance.

  10. Is the 5441-691 suitable for redundant control configurations?
    Yes. Multiple modules can be wired in parallel or series configurations to implement redundant or fail-safe control schemes.


Recommended Related モデルs

モデル Number 説明
5441-690 Relay Field Terminal Module, standard version
5441-692 High-density relay terminal module
5441-693 Isolated relay interface with extended inputs
5441-694 Dual-channel relay field module
5441-695 Heavy-duty industrial relay termination board
5441-696 Compact relay interface for confined installations

Popular Woodward モデルs

モデル Number 説明
5417-028 Shielded high-EMI industrial control cable
5466-353 Overspeed protection module for turbine systems
5501-471 Power management controller
9907-014 Digital speed control module
8200-226 Advanced actuator control module
5417-040 Extended-length industrial connection cable

会社情報

E-mail: [email protected]

Mobile:メールでのお問い合わせ

Whatsapp:メールでのお問い合わせ

Add: 中国福建省廈門市思明区呂嶺路2号 阿里山ビル 〒361006

サービス内容

当社は産業用オートメーション部品の供給を専門としており、1年間の保証を提供しております。当社の産業用オートメーション部品は世界中に販売されています。

当社は様々な国やメーカーの機器及びスペアパーツを提供し、複数拠点でのご不安や品質問題を解消するとともに、大きな価格メリットを実現しております。

製品詳細については、お気軽にお電話にてお問い合わせください。

製品保証とお客様サポート

保証詳細
  • 2年間標準保証 – 材料および製造上の欠陥をカバー
  • オプション延長保証 – 最大5年まで延長可能
  • オンサイト技術サポート – 工場トレーニングを受けたエンジニアが対応
  • 交換プログラム – 48時間以内の優先交換
  • 継続的技術支援 – 全製品のライフタイムサポート
品質コンプライアンス
  • 100%テスト済み・検証済み – 出荷前に各ユニットを検査
  • ISO 9001認証取得 – 品質マネジメントシステム準拠
  • 環境コンプライアンス – RoHSおよびCE基準準拠
  • 国際安全認証 – UL、cUL、その他該当する認証
  • トレーサブル生産 – 完全なシリアルおよびバッチ追跡
返品・交換ポリシー
  • 30日間返品期間 – 未使用製品の返金
  • 再入庫手数料なし – 追加料金なしで返品処理
  • 返品送料無料 – 不良品または誤品の場合
  • 交換品先行発送 – 交換中のダウンタイムを最小化
  • 簡単RMA手続き – オンライン返品承認が可能
お客様の権利とサポート
  • プライスマッチ保証 – 30日間の製品価格保護
  • 優先在庫確保 – リピーター様向け優先在庫
  • 技術トレーニング – オンラインおよびオンサイトでの製品トレーニング
  • 統合支援 – PLC/DCS統合のエンジニアリングサポート
  • レガシー製品サポート – 製造中止モジュールの継続サービス
保証規約
保証対象:
  • 材料および製造上の欠陥
  • 通常使用下での部品故障
  • ファームウェアまたはソフトウェアの問題(アップデート提供)
  • ドキュメントの誤りまたは欠落
保証除外事項:
  • 誤った設置または不適切な使用
  • 無許可の改造または修理
  • 事故、誤用、または不注意による損傷
  • 経年による通常の摩耗
重要事項:
  • すべての保証または返品リクエストには購入証明が必要です
  • 返品の際は元の梱包材を保管してください
  • カスタム設定品または特注品は異なる返品条件が適用される場合があります
  • 国際配送には追加の手続きや配送条件が適用される場合があります

技術文書

Check out Woodward 5441-691 Relay Field Terminal Module latest technical documentation.

お客様のレビュー

レビューを投稿

メールでのお問い合わせ [email protected] メールでのお問い合わせ Follow us on Facebook Subscribe on YouTube