Product 説明 The Honeywell RM7800L1012 is a microprocessor-based integrated burner control designed for single-burner, automatically fired gas, oil, or combination fuel applications. It manages

品番: 3133 在庫あり
Honeywell RM7800L1012 Burner Control

製品仕様

発売時期Jul 07, 2026
メーカー Honeywell DCS
モデル RM7800L1012
型番 IN3133
状態100%新品
出荷港中国廈門
リードタイム1-3営業日
認証COO
配送パートナーDHL, UPS, TNT, FedEx and EMS.
保証 1年間
単価
$529.00
USD / ユニット
-
+
最小注文: 1 台
0.0


配送情報
一定金額以上のご注文で送料無料 $5,000
東部標準時午後3時までのご注文は当日発送いたします。
国際配送可能
Honeywell RM7800L1012 Burner Control Honeywell RM7800L1012 Burner Control Honeywell RM7800L1012 Burner Control Honeywell RM7800L1012 Burner Control

Product 説明

The Honeywell RM7800L1012 is a microprocessor-based integrated burner control designed for single-burner, automatically fired gas, oil, or combination fuel applications. It manages burner sequencing, flame supervision, system diagnostics, and operational status indication. It is part / the reliable 7800 Series, /fering high safety and flexibility with advanced features such as Modbus communication, first-out annunciation, and self-check diagnostics.


Technical Specifications

Parameter Value
モデル RM7800L1012
Power Supply 120 VAC (+10/-15%), 50/60 Hz
Power Dissipation 10 W (relay), 3 W (display module)
Maximum Load 2000 VA
Operating Temperature -40°C to 60°C (-40°F to 140°F)
Storage Temperature -40°C to 66°C (-40°F to 150°F)
Humidity 85% RH, non-condensing
Vibration 0.5G
Dimensions 127 x 127 x 133 mm
重量 0.83 kg
Flame Failure Response 0.8 to 3 seconds (depending on amplifier)
Approvals UL, CSA, FM, SIL3 capable

Applications

  • Industrial boilers and burners in power plants.

  • Oil and gas processing facilities.

  • Chemical and petrochemical industries.

  • Food processing and manufacturing plants.

  • Any application requiring high-reliability burner control with flame monitoring.


Advantages

  • SIL3 capable for safety-critical applications.

  • Advanced diagnostics and first-out annunciation for quick troubleshooting.

  • Microprocessor-based design ensures high reliability and long life.

  • Flexible configuration with plug-in flame amplifiers and purge cards.

  • サポートs Modbus communication for integration into modern systems.

  • Nonvolatile memory retains history even after power loss.


FAQ

Q1: What is the primary function / the RM7800L1012?
A1: It provides automatic burner sequencing, flame supervision, and system diagnostics for single-burner applications.

Q2: Is the RM7800L1012 compatible with both gas and oil burners?
A2: Yes, it is designed for gas, oil, or combination fuel burners.

Q3: Does it support SIL3 safety level?
A3: Yes, when used in a properly designed safety system.

Q4: Can it communicate with a control system?
A4: Yes, via Modbus with an optional communication module.

Q5: What happens if there is a power loss?
A5: Its nonvolatile memory retains operational and fault history.

Q6: How is flame failure detected?
A6: Using compatible flame detectors and plug-in amplifiers, with a response time / 0.8–3 seconds.

Q7: Is remote reset possible?
A7: Yes, with the optional remote reset module.

Q8: What is the operating temperature range?
A8: From -40°C to 60°C (-40°F to 140°F).

Q9: Does it include a display for diagnostics?
A9: Yes, a vacuum fluorescent display provides operational and fault information.

Q10: How flexible is installation?
A10: It can be panel, wall, or burner mounted with various accessories.


Related モデルs

モデル 説明 Dimensions (mm) 重量 (kg)
RM7800E Burner control, FM/IRI rated 127 x 127 x 133 0.83
RM7800G Burner control, UL/CSA rated 127 x 127 x 133 0.83
RM7800M Burner control, On/Off type 127 x 127 x 133 0.83
RM7838A Advanced burner control 127 x 127 x 133 0.83
R7847C Self-check flame amplifier 25 x 75 x 50 0.1
R7852A Infrared flame amplifier 25 x 75 x 50 0.1

Popular Honeywell モデルs

モデル 説明 Dimensions (mm) 重量 (kg)
RM7890A Basic burner control 127 x 127 x 133 0.83
RM7895A Integrated burner control 127 x 127 x 133 0.83
RM7800L1087 Burner control with VPS 127 x 127 x 133 0.83
RM7823A Basic relay module 127 x 127 x 133 0.83
R7849A Ultraviolet flame amplifier 25 x 75 x 50 0.1
R7861A Self-check UV flame amplifier 25 x 75 x 50 0.1

会社情報

E-mail: [email protected]

Mobile:メールでのお問い合わせ

Whatsapp:メールでのお問い合わせ

Add: 中国福建省廈門市思明区呂嶺路2号 阿里山ビル 〒361006

サービス内容

当社は産業用オートメーション部品の供給を専門としており、1年間の保証を提供しております。当社の産業用オートメーション部品は世界中に販売されています。

当社は様々な国やメーカーの機器及びスペアパーツを提供し、複数拠点でのご不安や品質問題を解消するとともに、大きな価格メリットを実現しております。

製品詳細については、お気軽にお電話にてお問い合わせください。

製品保証とお客様サポート

保証詳細
  • 2年間標準保証 – 材料および製造上の欠陥をカバー
  • オプション延長保証 – 最大5年まで延長可能
  • オンサイト技術サポート – 工場トレーニングを受けたエンジニアが対応
  • 交換プログラム – 48時間以内の優先交換
  • 継続的技術支援 – 全製品のライフタイムサポート
品質コンプライアンス
  • 100%テスト済み・検証済み – 出荷前に各ユニットを検査
  • ISO 9001認証取得 – 品質マネジメントシステム準拠
  • 環境コンプライアンス – RoHSおよびCE基準準拠
  • 国際安全認証 – UL、cUL、その他該当する認証
  • トレーサブル生産 – 完全なシリアルおよびバッチ追跡
返品・交換ポリシー
  • 30日間返品期間 – 未使用製品の返金
  • 再入庫手数料なし – 追加料金なしで返品処理
  • 返品送料無料 – 不良品または誤品の場合
  • 交換品先行発送 – 交換中のダウンタイムを最小化
  • 簡単RMA手続き – オンライン返品承認が可能
お客様の権利とサポート
  • プライスマッチ保証 – 30日間の製品価格保護
  • 優先在庫確保 – リピーター様向け優先在庫
  • 技術トレーニング – オンラインおよびオンサイトでの製品トレーニング
  • 統合支援 – PLC/DCS統合のエンジニアリングサポート
  • レガシー製品サポート – 製造中止モジュールの継続サービス
保証規約
保証対象:
  • 材料および製造上の欠陥
  • 通常使用下での部品故障
  • ファームウェアまたはソフトウェアの問題(アップデート提供)
  • ドキュメントの誤りまたは欠落
保証除外事項:
  • 誤った設置または不適切な使用
  • 無許可の改造または修理
  • 事故、誤用、または不注意による損傷
  • 経年による通常の摩耗
重要事項:
  • すべての保証または返品リクエストには購入証明が必要です
  • 返品の際は元の梱包材を保管してください
  • カスタム設定品または特注品は異なる返品条件が適用される場合があります
  • 国際配送には追加の手続きや配送条件が適用される場合があります

技術文書

Check out Honeywell RM7800L1012 Burner Control latest technical documentation.

お客様のレビュー

レビューを投稿

メールでのお問い合わせ [email protected] メールでのお問い合わせ Follow us on Facebook Subscribe on YouTube