製品紹介
The Honeywell FC-BSN-1608 Safe NAMUR Sensor Converter is an advanced interface module specifically designed for converting NAMUR-type sensor signals into logic-level signals suitable for direct processing by safety systems such as Honeywell Fail Safe Controller (FSC) and Experion PKS architectures.
NAMUR sensors are widely used in critical applications that demand intrinsically safe field wiring and high-integrity signal isolation. The FC-BSN-1608 module is engineered to accept standard NAMUR signals and convert them reliably for safe operation in Safety Integrity Level (SIL) rated systems. This makes it an ideal component for safety-critical industries where functional safety compliance is required, including oil & gas, chemical processing, power generation, and pharmaceuticals.
The module ensures precise signal conditioning, provides fault detection (such as open/short circuits), and is fully certified for use in hazardous zones. It also includes channel-level diagnostics and galvanic isolation, safeguarding both field and control equipment from electrical disturbances.
The FC-BSN-1608 represents an essential part / modern process safety infrastructure, providing dependable, repeatable NAMUR signal interfacing across a range / industrial sectors.
製品仕様
| Parameter | Specification |
|---|---|
| Product Name | Honeywell FC-BSN-1608 Safe NAMUR Sensor Converter |
| 型番 | FC-BSN-1608 |
| System Compatibility | Honeywell FSC (Fail Safe Controller), Experion PKS |
| Input Type | NAMUR proximity sensors, contact sensors |
| Number / Channels | 16 isolated input channels |
| Input Signal Type | NAMUR EN 60947-5-6 compliant |
| Input Voltage Range | 8 VDC nominal |
| Input Current Levels | Sensor ON: ≤ 1.2 mA; Sensor OFF: ≥ 2.1 mA |
| Fault Detection | Short-circuit, open-circuit, line fault |
| Galvanic Isolation | Input-to-system logic and channel-to-channel |
| Diagnostics | Channel-level and module-level diagnostics |
| Indication LEDs | Per-channel input status, fault detection |
| Power Supply | 24 VDC nominal (redundant supported) |
| Power Consumption | < 6 W typical |
| Operating Temperature Range | -20°C to +60°C (-4°F to +140°F) |
| Storage Temperature Range | -40°C to +85°C (-40°F to +185°F) |
| Humidity Range | 5% to 95% RH (non-condensing) |
| Shock / Vibration Compliance | IEC 60068 compliant |
| Dimensions (H x W x D) | 128 x 50 x 145 mm |
| 重量 | 0.65 kg |
| Mounting Method | DIN rail or panel mount |
| Flame Rating | UL 94V-0 |
| Certifications | CE, UL, CSA, ATEX Zone 2, IECEx |
Applications
-
Signal conversion for NAMUR proximity and contact sensors
-
Emergency shutdown systems (ESD)
-
SIL-rated functional safety applications in oil & gas
-
Overpressure protection systems in chemical plants
-
Process shutdown and interlock functions in power generation
-
Intrinsically safe field device interfacing
-
Turbine and compressor monitoring systems
-
Rotating equipment protection
-
Sensor interfacing for pulp & paper machinery safety
-
Safety integration in pharmaceutical and life sciences plants
Product Advantages
-
High-integrity NAMUR conversion: Converts NAMUR sensor signals for safe processing
-
Multi-channel density: サポートs 16 channels in a compact module
-
Comprehensive fault detection: Identifies short-circuits, open-circuits, and line faults
-
Channel isolation: Full galvanic isolation protects both system logic and field devices
-
Redundant power support: Increases safety system uptime
-
LED diagnostics: Simplifies commissioning and maintenance with clear status indicators
-
Certified for hazardous areas: ATEX Zone 2 and IECEx certifications
-
Designed for SIL-rated applications: Suitable for use in high-integrity process safety loops
-
Rugged industrial design: Withstands environmental extremes common in heavy industries
-
Flexible mounting: DIN rail or panel mounting supports new build or retr/it projects
よくある質問 (FAQ)
-
What is the main purpose / the FC-BSN-1608?
It converts NAMUR sensor signals into digital signals usable by Honeywell FSC and Experion PKS systems. -
How many channels does this module provide?
It provides 16 isolated input channels. -
What type / sensors can it connect to?
It connects to NAMUR-compliant proximity sensors or contact sensors. -
Is it compatible with safety systems?
Yes — it is designed for SIL-rated safety applications and integrates with Honeywell FSC systems. -
What kinds / faults can the module detect?
It detects short-circuits, open-circuits, and line faults. -
Is galvanic isolation provided?
Yes — between input channels and from channels to system logic. -
Is it certified for hazardous areas?
Yes — ATEX Zone 2 and IECEx certified. -
What is the supported input current range?
Sensor ON: ≤ 1.2 mA; Sensor OFF: ≥ 2.1 mA. -
Does the module support redundant power?
Yes — it works with redundant 24 VDC power supplies. -
How is status indicated?
LEDs indicate channel status and fault conditions at both channel and module levels.
Related モデルs (Same Series or Product Line)
| モデル Number | 説明 |
|---|---|
| FC-BSN-1604 | 4-Channel Safe NAMUR Sensor Converter |
| FC-DOX-0001 | Digital Output Module for FSC |
| FC-RLY-0002 | Relay Output Module for FSC |
| FC-CPU-0001 | FSC Main CPU Module |
| FC-BKM-0001 | Battery and Key Switch Module |
| FC-PSU-0001 | Power Supply Module for FSC |
Popular Honeywell モデルs (Same ブランド)
| モデル Number | 説明 |
|---|---|
| C300 Controller | Advanced Process Controller |
| HC900 Hybrid Controller | Hybrid Process and Safety Controller |
| FSC 10101 | High Integrity Safety Controller |
| RM7800 | Integrated Burner Management Control Module |
| UCN I/O Rack | Universal Control Network I/O Rack |
| S9000 PLC | Modular Safety PLC for industrial automation |
会社情報
E-mail: [email protected]
Mobile:メールでのお問い合わせ
Whatsapp:メールでのお問い合わせ
Add: 中国福建省廈門市思明区呂嶺路2号 阿里山ビル 〒361006
サービス内容
当社は産業用オートメーション部品の供給を専門としており、1年間の保証を提供しております。当社の産業用オートメーション部品は世界中に販売されています。
当社は様々な国やメーカーの機器及びスペアパーツを提供し、複数拠点でのご不安や品質問題を解消するとともに、大きな価格メリットを実現しております。
製品詳細については、お気軽にお電話にてお問い合わせください。