製品紹介 The HIMA F3328A is a safety-related switching amplifier engineered for high-integrity industrial automation systems. As part / HIMAs renowned safety system platform, this module

品番: 3001
TAGS:
在庫あり
HIMA F3328A Safety Related Switching Amplifiers

製品仕様

発売時期Jul 07, 2026
メーカー Hima DCSモジュール
モデル F3328A
型番 IN3001
状態100%新品
出荷港中国廈門
リードタイム1-3営業日
認証COO
配送パートナーDHL, UPS, TNT, FedEx and EMS.
保証 1年間
単価
$1,559.00
USD / ユニット
-
+
最小注文: 1 台
0.0


配送情報
一定金額以上のご注文で送料無料 $5,000
東部標準時午後3時までのご注文は当日発送いたします。
国際配送可能
HIMA F3328A Safety Related Switching Amplifiers HIMA F3328A Safety Related Switching Amplifiers HIMA F3328A Safety Related Switching Amplifiers HIMA F3328A Safety Related Switching Amplifiers

製品紹介

The HIMA F3328A is a safety-related switching amplifier engineered for high-integrity industrial automation systems. As part / HIMA’s renowned safety system platform, this module is specially designed for use in environments where functional safety and reliability are paramount, including chemical plants, refineries, oil & gas pipelines, and other critical infrastructure. The F3328A module ensures galvanic isolation, signal amplification, and logic-level interfacing between field devices and safety-related control systems.

It is integrated into the HIMA Planar F-series platform and conforms to strict international safety standards such as IEC 61508 SIL 3, providing robust performance in demanding safety-critical applications. The compact yet robust build / the module makes it ideal for DIN rail mounting within tight control cabinets.


Technical Specifications

Below is a detailed technical overview / the HIMA F3328A Safety-Related Switching Amplifier:

Parameter Specification
Product Name HIMA F3328A Safety-Related Switching Amplifier
メーカー HIMA Paul Hildebrandt GmbH
System Compatibility HIMA Planar F Safety System
Input Type 1 or 2 digital input channels
Input Signal Level 15–30 V DC
Output Type Relay (potential-free contact)
お問い合わせ Rating 250 V AC / 30 V DC, 2 A
Response Time <10 ms
Switching Frequency Max. 10 Hz
Isolation Voltage ≥2.5 kV (Galvanic Isolation)
Safety Integrity Level (SIL) SIL 3 (IEC 61508), EN 50156
Power Supply 24 V DC ±10%
Power Consumption Approx. 1.2 W
Temperature Range -20°C to +60°C
Mounting Type DIN Rail Mounting
Housing Material Polycarbonate (Flame-retardant)
Dimensions (W×H×D) 120 x 160 x 40 mm
重量 1 kg
Certifications CE, ATEX, IECEx, TÜV Approved
Cooling Natural Convection
Protection Class IP20

Product Applications

The HIMA F3328A is designed for use in a wide variety / safety-critical environments:

  • Process Industry: Monitoring emergency shutdown signals in refineries, petrochemical plants, and power generation facilities.

  • Railway Systems: Integration in signal and control 台s where secure switching is required.

  • Oil and Gas: Offshore platforms and onshore stations requiring SIL-rated switching modules.

  • Pharmaceutical Plants: Ensures safe operation and shutdown in cleanroom and hazardous environments.

  • Chemical Industry: Used in explosion-prone environments to safely isolate and amplify digital control signals.

  • Energy Sector: For interfacing high-reliability sensors and actuators with emergency control systems.


Product Advantages

  • High Safety Integrity: Certified to SIL 3, providing reliable performance in life-critical applications.

  • Galvanic Isolation: Ensures complete electrical isolation between field inputs and control logic circuits.

  • Compact Design: Slim 18mm width fits easily into standard DIN rail enclosures without requiring excessive space.

  • Fast Switching: Enables high-speed response with minimal latency (<10 ms), essential in emergency shutdown scenarios.

  • Robust Compatibility: Seamlessly integrates with HIMA Planar F-series systems and a wide range / field devices.

  • Low Power Consumption: Energy-efficient operation ensures long-term cost savings.

  • ATEX & IECEx Certified: Approved for use in explosive atmospheres, supporting hazardous area installations.

  • Long Lifecycle: Designed for durability, ensuring low maintenance and high system availability over years / operation.


よくある質問 (FAQ)

  1. What is the primary function / the HIMA F3328A?
    The F3328A amplifies and switches digital signals in safety-related systems, ensuring galvanic isolation and reliability.

  2. Is the F3328A certified for SIL 3 applications?
    Yes, it is certified according to IEC 61508 for use in SIL 3 systems.

  3. What type / outputs does the F3328A provide?
    It /fers potential-free relay contacts suitable for interfacing with control elements.

  4. Can the F3328A operate in hazardous areas?
    Yes, it is ATEX and IECEx certified, making it suitable for explosive atmospheres.

  5. What input voltage range does the F3328A support?
    It accepts input signal levels between 15 and 30 V DC.

  6. How is the module mounted in a control panel?
    It is designed for DIN rail mounting, suitable for standard electrical enclosures.

  7. Does the F3328A support redundancy or diagnostics?
    It does not have built-in diagnostics but is compatible with HIMA safety system diagnostics.

  8. What is the weight / the F3328A module?
    It weighs 1 kg.

  9. What is the maximum switching frequency / this amplifier?
    The maximum recommended switching frequency is 10 Hz.

  10. Is the F3328A compatible with legacy HIMA systems?
    Yes, it integrates well with both legacy and modern HIMA Planar F control platforms.


Related モデルs from the Same Series

モデル 説明 SIL Level Input Type Output Type
F3328 Switching amplifier without advanced diagnostics SIL 3 Digital (DC) Relay output
F3330 Dual-channel safety switching amplifier SIL 3 2 × Digital Relay
F3331 Digital output module for emergency control SIL 3 Internal system input Solid-state output
F3221 Analog input module with isolation SIL 3 Analog (4–20 mA) Bus interface
F8650X CPU module for safety control systems SIL 3 System Integration Logic Control
F6208 Power supply module for Planar F system N/A 24 V DC input Internal bus supply

Popular モデルs from HIMA (Same ブランド)

モデル Function System SIL Level Application
F8621A CPU module with Ethernet and serial ports HIMax SIL 3 Central processing for safety logic
F7553 Communication module for PROFIBUS-DP HIMatrix N/A Industrial fieldbus communication
F8650X Redundant CPU system with SIL 3 Planar F SIL 3 Safety control and shutdown systems
F7133 Analog input module HIMatrix SIL 2 Analog signal monitoring
F6705 Power supply monitoring module Planar X N/A Voltage and current supervision
F3331 Relay output for emergency signals Planar F SIL 3 Critical shutdown signal relay

会社情報

E-mail: [email protected]

Mobile:メールでのお問い合わせ

Whatsapp:メールでのお問い合わせ

Add: 中国福建省廈門市思明区呂嶺路2号 阿里山ビル 〒361006

サービス内容

当社は産業用オートメーション部品の供給を専門としており、1年間の保証を提供しております。当社の産業用オートメーション部品は世界中に販売されています。

当社は様々な国やメーカーの機器及びスペアパーツを提供し、複数拠点でのご不安や品質問題を解消するとともに、大きな価格メリットを実現しております。

製品詳細については、お気軽にお電話にてお問い合わせください。

製品保証とお客様サポート

保証詳細
  • 2年間標準保証 – 材料および製造上の欠陥をカバー
  • オプション延長保証 – 最大5年まで延長可能
  • オンサイト技術サポート – 工場トレーニングを受けたエンジニアが対応
  • 交換プログラム – 48時間以内の優先交換
  • 継続的技術支援 – 全製品のライフタイムサポート
品質コンプライアンス
  • 100%テスト済み・検証済み – 出荷前に各ユニットを検査
  • ISO 9001認証取得 – 品質マネジメントシステム準拠
  • 環境コンプライアンス – RoHSおよびCE基準準拠
  • 国際安全認証 – UL、cUL、その他該当する認証
  • トレーサブル生産 – 完全なシリアルおよびバッチ追跡
返品・交換ポリシー
  • 30日間返品期間 – 未使用製品の返金
  • 再入庫手数料なし – 追加料金なしで返品処理
  • 返品送料無料 – 不良品または誤品の場合
  • 交換品先行発送 – 交換中のダウンタイムを最小化
  • 簡単RMA手続き – オンライン返品承認が可能
お客様の権利とサポート
  • プライスマッチ保証 – 30日間の製品価格保護
  • 優先在庫確保 – リピーター様向け優先在庫
  • 技術トレーニング – オンラインおよびオンサイトでの製品トレーニング
  • 統合支援 – PLC/DCS統合のエンジニアリングサポート
  • レガシー製品サポート – 製造中止モジュールの継続サービス
保証規約
保証対象:
  • 材料および製造上の欠陥
  • 通常使用下での部品故障
  • ファームウェアまたはソフトウェアの問題(アップデート提供)
  • ドキュメントの誤りまたは欠落
保証除外事項:
  • 誤った設置または不適切な使用
  • 無許可の改造または修理
  • 事故、誤用、または不注意による損傷
  • 経年による通常の摩耗
重要事項:
  • すべての保証または返品リクエストには購入証明が必要です
  • 返品の際は元の梱包材を保管してください
  • カスタム設定品または特注品は異なる返品条件が適用される場合があります
  • 国際配送には追加の手続きや配送条件が適用される場合があります

技術文書

Check out HIMA F3328A Safety Related Switching Amplifiers latest technical documentation.

お客様のレビュー

レビューを投稿

メールでのお問い合わせ [email protected] メールでのお問い合わせ Follow us on Facebook Subscribe on YouTube