見積もり (0)

HIMA F3217 8 Channel Safety Related Input Module

製品紹介 The HIMA F3217 is an advanced 8-channel safety-related input module designed to provide high-level reliability and safety for industrial control systems. This module is part / HI

品番: 2947
TAGS:
在庫あり
HIMA F3217 8 Channel Safety Related Input Module

製品仕様

発売時期Jul 07, 2026
メーカー Hima DCSモジュール
モデル F3217
型番 IN2947
状態100%新品
出荷港中国廈門
リードタイム1-3営業日
認証COO
配送パートナーDHL, UPS, TNT, FedEx and EMS.
保証 1年間
単価
$1,939.00
USD / ユニット
-
+
最小注文: 1 台
0.0


配送情報
一定金額以上のご注文で送料無料 $5,000
東部標準時午後3時までのご注文は当日発送いたします。
国際配送可能
HIMA F3217 8 Channel Safety Related Input Module HIMA F3217 8 Channel Safety Related Input Module HIMA F3217 8 Channel Safety Related Input Module HIMA F3217 8 Channel Safety Related Input Module

製品紹介

The HIMA F3217 is an advanced 8-channel safety-related input module designed to provide high-level reliability and safety for industrial control systems. This module is part / HIMA’s extensive family / safety systems, /fering robust performance for applications that require SIL 3 (Safety Integrity Level 3) certification. It is used primarily in safety-critical environments, such as process automation, emergency shutdown systems (ESD), and other safety-related tasks. The F3217 module ensures that critical safety functions are consistently maintained while meeting strict international standards for industrial safety.

With 8 input channels, this module allows for the connection / a variety / field devices, ensuring that signals are correctly monitored and processed. Its reliability and fault-tolerant design make it an essential part / any high-integrity system, providing comprehensive safety coverage for both small and large-scale automation systems.


製品仕様

Parameter Details
モデル Number F3217
Type 8 Channel Safety Related Input Module
Input Channels 8 (digital)
Safety Integrity Level SIL 3 (Safety Integrity Level 3)
Nominal Input Voltage 24 V DC
Input Type Digital (Dry お問い合わせ / Dry Closure)
Signal Monitoring Redundant monitoring for high safety assurance
Fault Tolerance 2oo3 (two out / three) voting system
Temperature Range -40°C to +70°C (-40°F to +158°F)
Mounting Type DIN Rail
Dimensions (Module) 200 x 100 x 35 mm
重量 (Module) 0.3 kg
Response Time < 1 ms
Power Consumption 0.7 W (maximum)
Certifications SIL 3, IEC 61508, IEC 61511, UL, CE
Connection Interface Screw terminal blocks
Status Indicators LEDs for each channel (ON/OFF and fault indication)
Protection Short-circuit and overload protection

Product Applications

The HIMA F3217 8 Channel Safety Related Input Module is designed for use in various safety-critical applications, ensuring that safety functions are always operational:

  • Process Control: For monitoring and controlling processes in industries like chemical, oil & gas, and pharmaceuticals.

  • Emergency Shutdown Systems (ESD): Ensures that emergency shutdown signals are safely processed and executed.

  • Fire & Gas Detection: Monitors fire and gas detection systems to initiate appropriate actions if hazardous conditions are detected.

  • Machine Safety: Used in safety systems for monitoring emergency stops, protective doors, and safety light curtains in manufacturing environments.

  • Safety Instrumented Systems (SIS): A key component in safety instrumented systems for providing fail-safe operation.

  • Power Generation: Used for monitoring critical parameters in power plants, ensuring the integrity / safety systems.


Product Advantages

  • High Reliability: The module is designed for high fault tolerance, ensuring that safety functions are not compromised even under challenging conditions.

  • Safety Integrity Level 3 (SIL 3): The F3217 meets the highest safety integrity standards, making it ideal for critical safety applications.

  • Fast Response Time: With a response time / less than 1 ms, the module ensures rapid detection and response to unsafe conditions.

  • Flexible Input Options: The module supports dry contact inputs, /fering flexibility in connecting various types / field devices.

  • Robust Environmental Performance: Designed to operate in extreme temperatures ranging from -40°C to +70°C, making it suitable for harsh industrial environments.

  • Easy Installation: The module can be easily mounted on a standard DIN rail, simplifying installation and integration into control panels.

  • Comprehensive Monitoring: Redundant monitoring and fault detection ensure that the system operates at peak reliability.

  • Long-term Durability: Built to last, with protection against short-circuits and overloads to extend the lifespan / both the module and the connected devices.


よくある質問 (FAQ)

  1. What is the primary function / the HIMA F3217 module?

    • It provides 8 digital input channels for safety-related applications, ensuring high reliability and fault tolerance for critical control systems.

  2. What does SIL 3 certification mean?

    • SIL 3 certification indicates that the module meets the highest safety integrity standards, making it suitable for high-risk applications.

  3. Can the F3217 module be used in harsh environments?

    • Yes, it operates in a wide temperature range from -40°C to +70°C, making it suitable for a variety / industrial environments.

  4. What type / inputs does the F3217 support?

    • The module supports dry contact inputs (dry closure), which are common for digital on//f signals from field devices.

  5. How does the F3217 ensure safety in case / a fault?

    • The module uses a 2oo3 (two out / three) voting system to ensure that a single fault does not compromise safety.

  6. Is the F3217 easy to integrate into existing systems?

    • Yes, the module can be easily integrated into safety instrumented systems and process control systems, thanks to its standardized DIN rail mounting and simple screw terminal connections.

  7. What industries can benefit from the F3217 module?

    • The F3217 is ideal for industries such as oil & gas, chemicals, pharmaceuticals, power generation, and manufacturing.

  8. Does the module /fer fault indication?

    • Yes, it has built-in LEDs that indicate the status / each channel, including any faults.

  9. What certifications does the F3217 module have?

    • It is certified for SIL 3, IEC 61508, IEC 61511, UL, and CE, ensuring compliance with international safety standards.

  10. What is the power consumption / the F3217 module?

    • The module consumes a maximum / 0.7 W / power during operation.


Related モデルs (Same Series or Functionality)

モデル Number 説明
F3227 16-channel Safety Input Module with similar safety features
F3207 4-channel Safety Input Module, smaller form factor
F3210 8-channel Input Module with enhanced diagnostics capabilities
F3237 12-channel Safety Input Module for larger-scale systems
F3247 8-channel Input Module with integrated relay outputs
F3267 High-density input module with extended fault tolerance

Popular モデルs from HIMA (その他 Categories)

モデル Number Type 説明
F2130 Safety Related Output Module Output module for controlling safety-critical actuators
F3000 Safety Controller Module Centralized safety controller for various safety systems
F2132 2-channel Safety Output Module Compact output module for small safety systems
F3100 Safety I/O Module Modular I/O system for safety applications
F3120 Safety Interface Module Interfaces external devices with the safety controller
F3140 Advanced Safety Controller High-performance controller for large-scale safety systems

会社情報

E-mail: [email protected]

Mobile:メールでのお問い合わせ

Whatsapp:メールでのお問い合わせ

Add: 中国福建省廈門市思明区呂嶺路2号 阿里山ビル 〒361006

サービス内容

当社は産業用オートメーション部品の供給を専門としており、1年間の保証を提供しております。当社の産業用オートメーション部品は世界中に販売されています。

当社は様々な国やメーカーの機器及びスペアパーツを提供し、複数拠点でのご不安や品質問題を解消するとともに、大きな価格メリットを実現しております。

製品詳細については、お気軽にお電話にてお問い合わせください。

製品保証とお客様サポート

保証詳細
  • 2年間標準保証 – 材料および製造上の欠陥をカバー
  • オプション延長保証 – 最大5年まで延長可能
  • オンサイト技術サポート – 工場トレーニングを受けたエンジニアが対応
  • 交換プログラム – 48時間以内の優先交換
  • 継続的技術支援 – 全製品のライフタイムサポート
品質コンプライアンス
  • 100%テスト済み・検証済み – 出荷前に各ユニットを検査
  • ISO 9001認証取得 – 品質マネジメントシステム準拠
  • 環境コンプライアンス – RoHSおよびCE基準準拠
  • 国際安全認証 – UL、cUL、その他該当する認証
  • トレーサブル生産 – 完全なシリアルおよびバッチ追跡
返品・交換ポリシー
  • 30日間返品期間 – 未使用製品の返金
  • 再入庫手数料なし – 追加料金なしで返品処理
  • 返品送料無料 – 不良品または誤品の場合
  • 交換品先行発送 – 交換中のダウンタイムを最小化
  • 簡単RMA手続き – オンライン返品承認が可能
お客様の権利とサポート
  • プライスマッチ保証 – 30日間の製品価格保護
  • 優先在庫確保 – リピーター様向け優先在庫
  • 技術トレーニング – オンラインおよびオンサイトでの製品トレーニング
  • 統合支援 – PLC/DCS統合のエンジニアリングサポート
  • レガシー製品サポート – 製造中止モジュールの継続サービス
保証規約
保証対象:
  • 材料および製造上の欠陥
  • 通常使用下での部品故障
  • ファームウェアまたはソフトウェアの問題(アップデート提供)
  • ドキュメントの誤りまたは欠落
保証除外事項:
  • 誤った設置または不適切な使用
  • 無許可の改造または修理
  • 事故、誤用、または不注意による損傷
  • 経年による通常の摩耗
重要事項:
  • すべての保証または返品リクエストには購入証明が必要です
  • 返品の際は元の梱包材を保管してください
  • カスタム設定品または特注品は異なる返品条件が適用される場合があります
  • 国際配送には追加の手続きや配送条件が適用される場合があります

技術文書

Check out HIMA F3217 8 Channel Safety Related Input Module latest technical documentation.

お客様のレビュー

レビューを投稿

メールでのお問い合わせ [email protected] メールでのお問い合わせ Follow us on Facebook Subscribe on YouTube