Product Overview
The Epro PR6426/010-110+CON021 32mm Eddy-Current Sensor is a precision non-contact measurement system designed for monitoring shaft displacement, vibration, eccentricity, and position in high-performance turbomachinery. This model integrates the PR6426/010-110 probe with the CON021 signal converter, ensuring accurate signal processing and compatibility with advanced condition monitoring systems. It is widely used in turbines, compressors, pumps, and critical rotating machinery where reliable measurement is essential.
Key Features
-
High sensitivity / 2 V/mm (50.8 mV/mil) with excellent accuracy
-
Wide static measurement range / ±4.0 mm (0.157”)
-
Low long-term drift (< 0.3%) for stable monitoring
-
Nominal air gap / 5.5 mm (0.22”) for precise operation
-
Non-contact sensing technology eliminates wear
-
Robust construction for harsh industrial environments
-
Integrated CON021 converter for signal conditioning and system compatibility
Technical Specifications
| Feature | Specification |
|---|---|
| モデル Number | PR6426/010-110+CON021 |
| Type | Eddy-Current Sensor with Signal Converter |
| Output Signal | 0.5 V DC to 4.5 V DC |
| Frequency Range | 0 to 20 kHz |
| Operating Temperature | -25°C to +85°C |
| Protection Class | IP67 |
| Cable Length | 5 meters armored cable |
| Dimensions | Sensor head diameter 32 mm |
| 重量 | 0.92 kg |
| Applications | Turbines, compressors, pumps, fans |
Industry Applications
-
Turbine shaft displacement and vibration monitoring
-
Compressor rotor position and eccentricity measurement
-
Pump alignment and dynamic condition tracking
-
Fan and general rotating equipment diagnostics
-
Power generation and oil & gas monitoring systems
Advantages
-
Reliable non-contact operation ensures long service life
-
High accuracy and stability for critical machine protection
-
Compatible with standard monitoring systems via CON021
-
Easy installation and integration into existing setups
-
Durable design withstands vibration, shocks, and contamination
-
Enhances predictive maintenance and machine safety
よくある質問 (FAQ)
Q1: What is the output range / the PR6426/010-110+CON021?
A1: The sensor provides a DC output signal from 0.5 V to 4.5 V.
Q2: What is the nominal measurement range?
A2: It supports a static measurement range / ±4.0 mm (0.157”).
Q3: What is the protection class rating?
A3: The sensor has an IP67 rating for protection against dust and water.
Q4: What is the operating temperature range?
A4: It operates reliably between -25°C and +85°C.
Q5: How long is the cable supplied with the sensor?
A5: The standard version comes with a 5-meter armored cable.
Q6: Can this sensor be used in predictive maintenance programs?
A6: Yes, it is commonly used in condition monitoring systems for predictive maintenance.
Q7: Which industries typically use this sensor?
A7: Power generation, petrochemical, oil & gas, and heavy industry.
Q8: What is the function / the CON021 signal converter?
A8: It processes and conditions the probe’s raw signal for compatibility with monitoring equipment.
Related Epro Sensors
| モデル Number | 説明 |
|---|---|
| PR6426/010-100 | 32mm Eddy-Current Sensor |
| PR6426/010-120 | 32mm Eddy-Current Sensor |
| PR6426/010-140 | 32mm Eddy-Current Sensor |
| PR6426/010-160 | 32mm Eddy-Current Sensor |
| PR6426/010-180 | 32mm Eddy-Current Sensor |
| PR6426/010-200 | 32mm Eddy-Current Sensor |
Popular Epro Sensors
| モデル Number | 説明 |
|---|---|
| PR6423/003-020 | 8mm Eddy-Current Sensor |
| PR6423/010-130 | 8mm Eddy-Current Sensor |
| PR6423/000-031+CON041 | 8mm Eddy-Current Sensor |
| PR6423/004-010-CN | 8mm Eddy-Current Sensor |
| PR6424/010-000 | 25mm Eddy-Current Sensor |
| PR6425/010-000 | 50mm Eddy-Current Sensor |
会社情報
E-mail: [email protected]
Mobile:メールでのお問い合わせ
Whatsapp:メールでのお問い合わせ
Add: 中国福建省廈門市思明区呂嶺路2号 阿里山ビル 〒361006
サービス内容
当社は産業用オートメーション部品の供給を専門としており、1年間の保証を提供しております。当社の産業用オートメーション部品は世界中に販売されています。
当社は様々な国やメーカーの機器及びスペアパーツを提供し、複数拠点でのご不安や品質問題を解消するとともに、大きな価格メリットを実現しております。
製品詳細については、お気軽にお電話にてお問い合わせください。