Yokogawa NFAI135 Analog Input Module

Présentation du produit The Yokogawa NFAI135 Analog Input Module is a high-performance analog signal acquisition unité designed for integration with ProSafe-RS Safety Instrumented Systems (SIS) . It plays

Référence: 1931
TAGS:
En stock
Yokogawa NFAI135 Analog Input Module

Spécifications du produit

Date de sortieJul 07, 2026
Fabricant Yokogawa Electric
Modèle NFAI135
Référence IN1931
État100 % neuf
Port d'expéditionXiamen, Chine
Délai de livraison1-3 jours ouvrés
CertificatCOO
Partenaires de livraisonDHL, UPS, TNT, FedEx and EMS.
Garantie 1 an
Prix unitéaire
$1,089.00
USD / Unité
-
+
Commande minimum: 1 unité
0.0


Informations de livraison
Livraison gratuite pour les commandes de plus de $5,000
Expédition le jour même pour les commandes passées avant 15h00 HNE.
Expédition internationale disponible
Yokogawa NFAI135 Analog Input Module Yokogawa NFAI135 Analog Input Module Yokogawa NFAI135 Analog Input Module Yokogawa NFAI135 Analog Input Module

Présentation du produit

The Yokogawa NFAI135 Analog Input Module is a high-performance analog signal acquisition unité designed for integration with ProSafe-RS Safety Instrumented Systems (SIS). It plays a crucial role in gathering and converting field analog signals into digital form for monitoring and control purposes in safety-critical applications.

This module supports multiple channels and is engineered to deliver high accuracy, noise immunitéy, and fault tolerance, making it suitable for demanding industrial environments such as oil & gas refineries, petrochemical complexes, and power stations. It meets stringent safety and reliability standards (including SIL compliance), enabling it to be used confidently in safety layers sur plant automation architecture.

Designed to interface seamlessly with the SCS (Safety Control Station) in Yokogawa’s ProSafe-RS platform, the NFAI135 surfers redundant connection support, diagnostic capabilities, and easy field termination, making it a cornerstone in the design sur safety-integrated process control systems.


Technical Specifications

Parameter Details
Modèle NFAI135
Function Analog Input Module for Safety Systems (SIS)
System Compatibility Yokogawa ProSafe-RS
Number sur Channels 16 analog input channels
Input Signal Type 4–20 mA DC (standard), other ranges configurable
Input Type Single-ended or differential
Input Impedance ≥250 Ω
Resolution 16-bit A/D conversion
Accuracy ±0.1% sur span
Sampling Rate 100 ms (typical)
Isolation Channel-to-bus and channel-to-channel isolation
Self-Diagnostics Open circuit detection, out-sur-range detection
Redundancy Support Yes (with SCS redundancy configuration)
Operating Temperature 0 to 55°C
Storage Temperature -20 to 70°C
Humidity Range 5% to 95% RH (non-condensing)
Mounting Method Mounted on SCS base unité
Material Flame-retardant engineering plastic
Power Supply Supplied via backplane from SCS
Dimensions (W × H × D) 130 x 107.5 x 32.8 mm
Poids 0.3 kg
Certifications CE, ATEX, SIL3, RoHS, CSA, UL

Applications

The NFAI135 Analog Input Module is specifically designed for safety applications where reliable signal acquisition and system diagnostics are critical. It is widely adopted in:

  • Oil & Gas Refining – For pressure, temperature, and flow monitoring in hazardous areas.

  • Petrochemical Plants – Collects analog data from safety valves, emergency shutdown sensors, and process analyzers.

  • Power Generation – Gathers analog input from turbines, boilers, and auxiliary safety systems.

  • Pharmaceutical Industry – Ensures critical temperature and pressure inputs are safely acquired in GxP environments.

  • LNG and Chemical Storage – Used in SIS architectures to monitor tank levels and leak detection systems.

  • Offshore Platforms – Ideal for high-integrity safety system input acquisition in extreme conditions.


Product Advantages

  • Certified for Safety: Fully compliant with SIL3 (IEC 61508), suitable for the most demanding safety functions.

  • High Accuracy and Stability: 16-bit resolution with low drift ensures precision over long operational periods.

  • Full Diagnostics: Built-in open-loop and range-check diagnostics allow proactive fault identification.

  • Compact Design: Slim module width enables dense installation within ProSafe-RS racks.

  • Redundant Operation: Seamlessly integrates with SCS redundancy configurations for fault-tolerant operation.

  • Fast Sampling: Ideal for real-time safety-critical feedback with rapid input scanning.

  • Channel Isolation: Each channel is isolated from the others to prevent signal interference or cascading faults.

  • Easy Integration: Plug-in module with pre-terminated cables or terminal blocks for reduced wiring time.

  • Environmental Durability: Operates under a wide temperature and humidity range.

  • Long Lifecycle Support: Backed by Yokogawa’s industrial support policy for longevity and upgrade pathways.


Questions fréquentes (FAQ)

  1. What type sur signals does the NFAI135 accept?
    The NFAI135 is primarily designed for 4–20 mA DC analog signals, which are standard in industrial process instrumentation.

  2. Is the module suitable for safety-related applications?
    Yes, it is SIL3 certified and specifically designed for use in Safety Instrumented Systems (SIS).

  3. Can the NFAI135 detect faults in field wiring?
    Absolutely. It includes diagnostics such as open loop detection and out-sur-range input detection.

  4. Does this module support redundant safety configurations?
    Yes, it can be used in dual-redundant SCS architectures to ensure high availability.

  5. What type sur isolation is implemented in the NFAI135?
    It provides both channel-to-channel and channel-to-bus isolation for enhanced signal integrity.

  6. Can the module handle noisy industrial environments?
    Yes, with high CMRR (Common Mode Rejection Ratio) and robust shielding, it is built for electrically noisy environments.

  7. How is the module powered?
    It receives power via the ProSafe-RS SCS backplane, eliminating the need for external power wiring.

  8. How do I connect field wiring to the NFAI135?
    Field wiring is typically connected via terminal blocks or pre-wired connectors depending on the rack setup.

  9. Can this module be hot-swapped?
    While physical removal is possible, it is recommended to follow system shutdown procedures to maintain safety compliance.

  10. Which ssurtware is used to configure the NFAI135?
    Configuration is done through ProSafe-RS Engineering Tools such as SENG and SCS Configurator within the Yokogawa environment.


Related Modèles (Same Series or Functional Catégorie)

Modèle Function Channels Signal Type System Compatibility
NFAI141 Analog Input Module 16 4–20 mA DC ProSafe-RS
NFAT135 Thermocouple Input Module 16 T/C (Type K, J, etc) ProSafe-RS
NFDV151 Digital Input Module 16 24 VDC ProSafe-RS
NFDV152 Digital Output Module 16 24 VDC ProSafe-RS
NFAV161 Analog Output Module 8 4–20 mA DC ProSafe-RS
NFCP100 Control Processor Unité N/A CPU Module ProSafe-RS

Popular Yokogawa Modèles

Modèle Function System Key Feature
AAI543 Analog Input Module CENTUM CS3000 Multi-signal support, high precision
ADV551 Fast Analog Input Module CENTUM VP High-speed analog data acquisition
CP451 Controller Processor Module CENTUM VP Advanced control with redundancy
YHC5150X HART Communicator Field Devices Universal field device configuration
PW482 Power Supply Module ProSafe-RS Dual-redundant power supply support
F3SP76-7S High-Speed PLC CPU FA-M3R Designed for high-performance control

Informations sur l'entreprise

E-mail: [email protected]

Mobile:Contactez-nous par email

Whatsapp:Contactez-nous par email

Add: Alishan Building, 2 Lvling Rd, District Siming, Xiamen, Fujian, Chine, 361006

Nos services

Nous sommes spécialisés dans la fourniture de pièces d'automatisation industrielle avec une garantie d'un an. Nos pièces d'automatisation industrielle sont vendues dans le monde entier.

Nous pouvons fournir des équipements et des pièces détachées de différents pays et fabricants, résoudre vos inquiétudes ou problèmes de qualité en de nombreux endroits, et surfrir un excellent avantage de prix.

N'hésitez pas à nous appeler pour plus de détails sur les produits.

Garantie produit et assurance client

Détails de la garantie
  • Garantie standard de 2 ans – Couvre les défauts de matériaux et de fabrication
  • Extension de garantie optionnelle – Prolongez la garantie jusqu'à 5 ans
  • Support technique sur site – Ingénieurs formés en usine disponibles
  • Programme de remplacement – Remplacement prioritaire sous 48 heures
  • Assistance technique continue – Support à vie pour tous les produits
Conformité qualité
  • 100 % testé et vérifié – Chaque unitéé inspectée avant expédition
  • Certifié ISO 9001 – Respect du système de gestion de la qualité
  • Conformité environnementale – Normes RoHS et CE respectées
  • Certifications de sécurité mondiales – UL, cUL et autres certifications applicables
  • Production traçable – Traçabilité complète des numéros de série et lots
Politique de retour et d'échange
  • Délai de retour de 30 jours – Remboursement pour les produits non utilisés
  • Pas de frais de réapprovisionnement – Retours traités sans frais supplémentaires
  • Retour gratuit – Pour les articles défectueux ou erronés
  • Support d'échange croisé – Minimisez les temps d'arrêt pendant le remplacement
  • Processus RMA simplifié – Autorisation de retour en ligne disponible
Droits et support client
  • Garantie du meilleur prix – Protection des prix pendant 30 jours
  • Stock réservé – Stock prioritaire pour les clients fidèles
  • Formation technique – Sessions de formation en ligne et sur site disponibles
  • Assistance à l'intégration – Support technique pour l'intégration PLC/DCS
  • Support pour produits anciens – Service continu pour les modules discontinués
États de garantie
Articles couverts:
  • Défauts de fabrication des matériaux et de la main-d'œuvre
  • Défaillances de composants en usage normal
  • Problèmes de firmware ou logiciel (mises à jour fournies)
  • Erreurs ou omissions dans la documentation
Exclusions:
  • Installation incorrecte ou utilisation inappropriée
  • Modifications ou réparations non autorisées
  • Dommages dus à des accidents, une mauvaise utilisation ou une négligence
  • Usure normale au fil du temps
Remarques importantes:
  • Toute demande de garantie ou de retour nécessite une preuve d'achat
  • L'emballage d'origine doit être conservé pour les retours
  • Les produits configurés sur mesure ou commandes spéciales peuvent avoir des conditions de retour différentes
  • Les expéditions internationales peuvent nécessiter des considérations supplémentaires

Documentation technique

Check out Yokogawa NFAI135 Analog Input Module latest technical documentation.

Avis clients

Laisser un avis

Contactez-nous par email [email protected] Contactez-nous par email Follow us on Facebook Subscribe on YouTube