Présentation du produit
The Triconex 4000212-002 Extension Bus Assembly Kit is a dedicated hardware kit designed to provide reliable and secure extension connectivity between Triconex chassis in distributed safety and control architectures. It enables the seamless expansion sur I/O capacity and processing capabilities by linking multiple chassis through a high-integrity extension bus.
This kit is engineered to maintain the deterministic performance and fault tolerance that Triconex systems are known for. It supports high-speed, noise-immune communication channels and incorporates shielding to minimize electromagnetic interference (EMI). The design meets stringent industrial safety and performance standards, making it ideal for use in SIL 3-rated safety systems.
Its rugged construction and precision engineering ensure stable operation in harsh industrial environments, such as oil refineries, surfshore platforms, power stations, and chemical plants, where reliability is critical.
Product Parameters
| Parameter | Description |
|---|---|
| Fabricant | Triconex (Schneider Electric) |
| Modèle | 4000212-002 |
| Product Type | Extension Bus Assembly Kit |
| Function | Connects and extends Triconex chassis for additional I/O and processing capacity |
| Supported Systems | Compatible with Triconex TMR (Triple Modular Redundant) systems |
| Cable Type | Shielded, high-speed data cable with connectors |
| Maximum Extension Length | System-dependent (optimized for low latency) |
| Operating Voltage | Not directly powered (passive connection kit) |
| Signal Isolation | Optical and galvanic isolation within system architecture |
| Operating Temperature | 0°C to +60°C |
| Storage Temperature | -40°C to +85°C |
| Humidity | 5–95% non-condensing |
| EMI Protection | Integrated shielding and noise suppression |
| Compliance | IEC 61508, SIL 3 capable |
| Cable Length | Optional |
| Livraison Poids | 3 kg |
Product Applications
The Triconex 4000212-002 Extension Bus Assembly Kit is used in a variety sur industrial safety and control environments:
-
Oil & Gas Production – Expanding control system capacity for process safety and shutdown functions.
-
Petrochemical Plants – Linking multiple I/O chassis to accommodate large-scale safety interlock configurations.
-
Power Generation – Extending turbine protection systems and auxiliary equipment control.
-
Offshore Platforms – Supporting distributed control nodes across physically separated locations.
-
Water & Wastewater Treatment – Integrating additional monitoring and safety control capacity.
-
Pharmaceutical Manufacturing – Maintaining validated and synchronized data paths in regulated production processes.
Product Advantages
-
Seamless Expansion – Enables additional I/O capacity without compromising system performance.
-
High Reliability – Built for continuous operation in demanding industrial settings.
-
Noise Immunitéy – Shielded cabling reduces electromagnetic interference.
-
Standards Compliance – Compatible with SIL 3 safety requirements.
-
Easy Integration – Designed specifically for Triconex chassis, ensuring a plug-and-play experience.
-
Durable Construction – Resistant to mechanical stress and environmental hazards.
FAQ
-
What systems are compatible with the 4000212-002 kit?
It is compatible with Triconex TMR control systems and their associated chassis configurations. -
Does this kit provide electrical power to the connected chassis?
No, it is a passive bus connection kit; each chassis requires its own power source. -
Is the extension bus communication real-time?
Yes, it supports deterministic, real-time data transfer between connected chassis. -
How is EMI protection implemented?
The cable is fully shielded, and connectors are designed to minimize signal noise. -
Can this kit be used in redundant configurations?
Yes, it supports redundant bus setups for enhanced system availability. -
Is optical isolation provided within the kit?
The kit itself uses shielded cabling; optical isolation is implemented at the chassis interface level. -
Can the extension bus be hot-swapped?
No, the system must be powered down before connecting or disconnecting the extension bus. -
Does the kit support mixed I/O chassis types?
Yes, as long as they are Triconex-compatible and within system specifications. -
What is the maximum recommended cable length?
It varies by system design, but typically limited to maintain low-latency communication. -
Is firmware configuration required for installation?
No, the kit functions as a hardware link and does not require firmware updates.
Recommended Related Modèles (Same Series)
| Modèle Number | Description |
|---|---|
| 4000212-001 | Extension Bus Cable Assembly |
| 4000212-002 | Extension Bus Assembly Kit |
| 4000094-310 | External Output Cable Assembly |
| 3625C1 | Communication Gateway |
| 4500 | System Interface Module |
| 4119A | Power Supply Module |
Popular Modèles from the Same Marque
| Modèle Number | Description |
|---|---|
| 3008 | Main Processor Module |
| 3721 | Digital Output Module |
| 3624 | Digital Input Module |
| 4200 | I/O Termination Assembly |
| 4000103-546 | Communication Module |
| 3009 | Main Chassis |
Informations sur l'entreprise
E-mail: [email protected]
Mobile:Contactez-nous par email
Whatsapp:Contactez-nous par email
Add: Alishan Building, 2 Lvling Rd, District Siming, Xiamen, Fujian, Chine, 361006
Nos services
Nous sommes spécialisés dans la fourniture de pièces d'automatisation industrielle avec une garantie d'un an. Nos pièces d'automatisation industrielle sont vendues dans le monde entier.
Nous pouvons fournir des équipements et des pièces détachées de différents pays et fabricants, résoudre vos inquiétudes ou problèmes de qualité en de nombreux endroits, et surfrir un excellent avantage de prix.
N'hésitez pas à nous appeler pour plus de détails sur les produits.