HIMA F8652X 984865265 Central Module

Présentation du produit The HIMA F8652X Central Module is a high-performance, dual-processor central unité developed specifically for HIMAs HIMax safety system architecture. It serves as the main controll

Référence: 2837 En stock
HIMA F8652X 984865265 Central Module

Spécifications du produit

Date de sortieJul 07, 2026
Fabricant Modules DCS Hima
Modèle F8652X 984865265
Référence IN2837
État100 % neuf
Port d'expéditionXiamen, Chine
Délai de livraison1-3 jours ouvrés
CertificatCOO
Partenaires de livraisonDHL, UPS, TNT, FedEx and EMS.
Garantie 1 an
Prix unitéaire
$1,719.00
USD / Unité
-
+
Commande minimum: 1 unité
0.0


Informations de livraison
Livraison gratuite pour les commandes de plus de $5,000
Expédition le jour même pour les commandes passées avant 15h00 HNE.
Expédition internationale disponible
HIMA F8652X 984865265 Central Module HIMA F8652X 984865265 Central Module HIMA F8652X 984865265 Central Module HIMA F8652X 984865265 Central Module

Présentation du produit

The HIMA F8652X Central Module is a high-performance, dual-processor central unité developed specifically for HIMA’s HIMax safety system architecture. It serves as the main controller responsible for executing safety logic, coordinating I/O communication, and interfacing with system diagnostics and communication modules. As part sur HIMA’s modular and scalable safety platform, the F8652X is designed for critical process safety applications that require the highest levels sur availability, fault tolerance, and system integrity.

Capable sur meeting SIL 3 safety requirements, the F8652X combines robust redundancy strategies with advanced diagnostics and seamless hot-swap functionality. Its architecture is tailored for use in industries where unplanned downtime and safety failures are not acceptable, such as oil and gas, chemical processing, power generation, and rail transportation.


Spécifications du produit

Parameter Details
Modèle Number F8652X
Fabricant HIMA
Function Central Processor Module
System Compatibility HIMax Safety System
Safety Integrity Level SIL 3 (IEC 61508)
Processor Type Dual-redundant CPUs with integrated memory
Memory Capacity Program and runtime memory integrated
Hot-Swappable Yes
Communication Ports System bus, Ethernet, RS485, optional PROFIBUS/Modbus
Diagnostic Features Extensive self-diagnostics and real-time monitoring
Status Indicators LED indicators for power, diagnostics, and operation
Power Supply 24 VDC nominal (range: 18–30 VDC)
Power Consumption Approx. 10 W
Operating Temperature 0°C to +60°C
Storage Temperature -40°C to +85°C
Humidity 5% to 95% non-condensing
Vibration Resistance Meets industrial standards (IEC 60068-2-6)
Shock Resistance Meets industrial standards (IEC 60068-2-27)
Dimensions (H x W x D) 257 x 114 x 30 mm
Poids 1.5 kg
Mounting Plug-in module for HIMax rack system
Certifications SIL 3 (TÜV), CE, IEC 61508, ATEX zone compatible

Applications

The HIMA F8652X is extensively used in sectors requiring high safety integrity, system availability, and functional flexibility. Key application areas include:

  • Oil & Gas Refining and Offshore Platforms – For emergency shutdown (ESD), fire and gas (F&G), and blowout prevention systems.

  • Chemical & Petrochemical Plants – Managing safety interlocks and critical processing sequences.

  • Power Generation Facilities – Used in turbine protection, generator synchronization, and boiler control systems.

  • Transportation and Rail Systems – Safety controls for signaling and train control systems.

  • Pharmaceutical Manufacturing – For fail-safe process control in regulated environments.

  • Water and Wastewater Treatment – Emergency response management and process safety.


Advantages

  • Redundant CPU Architecture: Built-in dual processors ensure continuous operation even in fault scenarios.

  • SIL 3 Certified: Complies with the highest safety integrity standards for mission-critical systems.

  • Comprehensive Diagnostics: Integrated real-time diagnostic functions allow predictive maintenance and fast fault isolation.

  • Modular Integration: Seamlessly fits into the HIMax rack and works with various I/O and communication modules.

  • Hot-Swap Support: Enables live replacement and maintenance without shutting down the system.

  • Flexible Communication: Supports multiple protocols including Ethernet, Modbus, and PROFIBUS for system interoperability.

  • Durable Construction: Engineered for industrial-grade temperature, vibration, and shock resistance.

  • Reduced Downtime: Designed to minimize system interruption through robust failover capabilities.


FAQ – Questions fréquentes

  1. What is the primary function sur the F8652X module?
    It acts as the central processor in the HIMax safety system, executing safety logic and managing system operations.

  2. Can the module be replaced while the system is running?
    Yes, the F8652X is hot-swappable, meaning it can be replaced without interrupting ongoing operations.

  3. Is it suitable for SIL 3 safety applications?
    Absolutely. It is certified to meet SIL 3 according to IEC 61508.

  4. What type sur communication protocols are supported?
    The module supports Ethernet, RS485, and optional integration with Modbus or PROFIBUS.

  5. How does the F8652X ensure system availability?
    Through its redundant dual-CPU architecture and real-time diagnostics, ensuring fault tolerance.

  6. What kind sur environments can it operate in?
    It operates in industrial conditions with temperatures from 0°C to +60°C and is resistant to vibration and shock.

  7. Is external programming required?
    Yes, programming is done through the SILworX engineering ssurtware provided by HIMA.

  8. Does the module include its own memory?
    Yes, it comes with integrated program and runtime memory.

  9. How is status information communicated to operators?
    Through front-panel LED indicators and diagnostic communication with the main system.

  10. What certifications does the F8652X hold?
    It is TÜV-certified for SIL 3, CE-marked, and conforms to ATEX and IEC 61508 standards.


Related Modèles (Same Series or Compatible)

Modèle Description Key Feature System
F8651E Central Module Dual CPU, high safety integration HIMax
F8650X CPU Module SIL 3, hot-swappable HIMax
F7550 CPU Redundancy Module Enhances processor fault tolerance HIMax
F7553 Communication Processor Module System-level data communication HIMax
F7505 I/O Controller Handles I/O routing and processing HIMax
F6705 Interface Module PROFIBUS/DP integration HIMax

Popular HIMA Modèles (Same Marque)

Modèle Description Application System
F3330 Analog Input Module Precise input for temperature, pressure, etc. HIMatrix
F3236 Analog Output Module Actuator and valve signal control HIMatrix
F7126 CPU Module for Compact Systems Used in smaller safety solutions HIMatrix
F8621A Digital Input Module Emergency button and sensor input HIMax
F7131 Communication Gateway Module Interfaces to higher-level systems HIMatrix
F7128 Safety Controller Module Standalone compact PLC HIMatrix

Informations sur l'entreprise

E-mail: [email protected]

Mobile:Contactez-nous par email

Whatsapp:Contactez-nous par email

Add: Alishan Building, 2 Lvling Rd, District Siming, Xiamen, Fujian, Chine, 361006

Nos services

Nous sommes spécialisés dans la fourniture de pièces d'automatisation industrielle avec une garantie d'un an. Nos pièces d'automatisation industrielle sont vendues dans le monde entier.

Nous pouvons fournir des équipements et des pièces détachées de différents pays et fabricants, résoudre vos inquiétudes ou problèmes de qualité en de nombreux endroits, et surfrir un excellent avantage de prix.

N'hésitez pas à nous appeler pour plus de détails sur les produits.

Garantie produit et assurance client

Détails de la garantie
  • Garantie standard de 2 ans – Couvre les défauts de matériaux et de fabrication
  • Extension de garantie optionnelle – Prolongez la garantie jusqu'à 5 ans
  • Support technique sur site – Ingénieurs formés en usine disponibles
  • Programme de remplacement – Remplacement prioritaire sous 48 heures
  • Assistance technique continue – Support à vie pour tous les produits
Conformité qualité
  • 100 % testé et vérifié – Chaque unitéé inspectée avant expédition
  • Certifié ISO 9001 – Respect du système de gestion de la qualité
  • Conformité environnementale – Normes RoHS et CE respectées
  • Certifications de sécurité mondiales – UL, cUL et autres certifications applicables
  • Production traçable – Traçabilité complète des numéros de série et lots
Politique de retour et d'échange
  • Délai de retour de 30 jours – Remboursement pour les produits non utilisés
  • Pas de frais de réapprovisionnement – Retours traités sans frais supplémentaires
  • Retour gratuit – Pour les articles défectueux ou erronés
  • Support d'échange croisé – Minimisez les temps d'arrêt pendant le remplacement
  • Processus RMA simplifié – Autorisation de retour en ligne disponible
Droits et support client
  • Garantie du meilleur prix – Protection des prix pendant 30 jours
  • Stock réservé – Stock prioritaire pour les clients fidèles
  • Formation technique – Sessions de formation en ligne et sur site disponibles
  • Assistance à l'intégration – Support technique pour l'intégration PLC/DCS
  • Support pour produits anciens – Service continu pour les modules discontinués
États de garantie
Articles couverts:
  • Défauts de fabrication des matériaux et de la main-d'œuvre
  • Défaillances de composants en usage normal
  • Problèmes de firmware ou logiciel (mises à jour fournies)
  • Erreurs ou omissions dans la documentation
Exclusions:
  • Installation incorrecte ou utilisation inappropriée
  • Modifications ou réparations non autorisées
  • Dommages dus à des accidents, une mauvaise utilisation ou une négligence
  • Usure normale au fil du temps
Remarques importantes:
  • Toute demande de garantie ou de retour nécessite une preuve d'achat
  • L'emballage d'origine doit être conservé pour les retours
  • Les produits configurés sur mesure ou commandes spéciales peuvent avoir des conditions de retour différentes
  • Les expéditions internationales peuvent nécessiter des considérations supplémentaires

Documentation technique

Check out HIMA F8652X 984865265 Central Module latest technical documentation.

Avis clients

Laisser un avis

Contactez-nous par email [email protected] Contactez-nous par email Follow us on Facebook Subscribe on YouTube