Angebot (0)

Yokogawa SEC402 ESB Bus Coupler Module

Produkteinführung The Yokogawa SEC402 is a high-performance ESB Bus Coupler Module that serves as a vital communication bridge within Yokogawas CENTUM VP and CENTUM CS 3000 Distributed Control Syst

Artikelnummer: 1873
TAGS:
Auf Lager
Yokogawa SEC402 ESB Bus Coupler Module

Produktspezifikationen

ErscheinungsdatumJul 07, 2026
Hersteller Yokogawa Electric
Modell SEC402
Artikelnummer IN1873
Zustand100 % neu
VersandhafenXiamen, China
Lieferzeit1-3 Werktage
ZertifikatCOO
KurierpartnerDHL, UPS, TNT, FedEx and EMS.
Garantie 1 Jahr
Stückpreis
$1,959.00
USD / Einheit
-
+
Mindestbestellung: 1 Stück
0.0


Versandinformationen
Kostenloser Versand für Bestellungen über $5,000
Bei Bestellungen vor 15:00 Uhr EST erfolgt der Versand am selben Tag.
Internationaler Versand verfügbar
Yokogawa SEC402 ESB Bus Coupler Module Yokogawa SEC402 ESB Bus Coupler Module Yokogawa SEC402 ESB Bus Coupler Module Yokogawa SEC402 ESB Bus Coupler Module

Produkteinführung

The Yokogawa SEC402 is a high-performance ESB Bus Coupler Module that serves as a vital communication bridge within Yokogawa’s CENTUM VP and CENTUM CS 3000 Distributed Control Systems (DCS). Its primary function is to interface the Field Control Station (FCS) with the I/O modules over the ESB (Enhanced System Backbone) bus, ensuring high-speed, synchronized, and reliable data transmission across control networks.

Designed with a focus on fault tolerance, redundancy, and modular expansion, the SEC402 supports both single and dual-redundant bus configurations. It enables seamless signal exchange between the control processor and I/O modules, while also vonfering robust electrical isolation and diagnostic functions. The module is known for its durability, efficient bus bandwidth utilization, and compatibility with Yokogawa’s wide range von FIO (Field I/O) modules.

Whether deployed in batch control systems, large process industries, or compact automation architectures, the SEC402 provides the backbone communication essential for maintaining reliable plant operations.


Produktspezifikationen

Parameter Beschreibung
Modell SEC402
Hersteller Yokogawa Electric Corporation
Product Type ESB Bus Coupler Module
System Compatibility CENTUM VP, CENTUM CS 3000
Bus Interface ESB (Enhanced System Backbone)
Redundancy Support Yes (Dual-redundant ESB bus capable)
Data Transmission High-speed serial (proprietary ESB protocol)
Module Type Passive interface
Power Supply Voltage Supplied via base plate (typically 24V DC)
Status Indicators LED indicators for power, communication, and fault diagnostics
Mounting Method Base-mounted on ESB backplane
Installation Environment Enclosed control cabinets
Operating Temperature 0°C to +55°C
Storage Temperature -20°C to +70°C
Humidity Range 10–90% RH, non-condensing
Insulation Resistance ≥100 MΩ (500V DC)
Dielectric Strength 1500V AC for 1 minute (between I/O and ground)
Dimensions (W × H × D) 130 x 129.5 x 32.8 mm
Gewicht 0.24 kg
Certifications CE, RoHS, CSA, ATEX, IECEx

Product Applications

The SEC402 Bus Coupler Module is extensively used in industrial settings where distributed I/O systems require consistent and high-speed communication between the Field Control Station and I/O nodes. Key application areas include:

  • Chemical Processing Plants – Ensures rapid and stable signal exchange for reaction and blending systems.

  • Petrochemical Refineries – Facilitates distributed I/O control across large plant areas.

  • Power Generation Facilities – Interfaces turbine and boiler I/O with core control systems.

  • Water and Wastewater Management – Connects remote valve and sensor signals over long distances.

  • Pharmaceutical Manufacturing – Maintains GMP-compliant, real-time data integration between control and field equipment.

  • Steel and Cement Industries – Supports precise synchronization between heavy-duty process modules.

The SEC402 is especially beneficial in redundant architectures, segment-isolated networks, and high-availability DCS platforms.


Product Advantages

  • Robust Bus Communication: Delivers reliable and high-speed communication over ESB architecture.

  • Redundancy Ready: Supports dual-redundant communication for fault-tolerant operation.

  • Compact and Modular: Fits seamlessly into existing Yokogawa baseplate configurations without modification.

  • Diagnostic Monitoring: Equipped with LEDs for real-time status, easing maintenance and fault detection.

  • Highly Compatible: Fully interoperable with Yokogawa’s I/O modules, processors, and FIO platforms.

  • Secure Electrical Isolation: Ensures safe operation by isolating I/O and control signals.

  • Industrial Durability: Designed to withstand temperature variations, vibration, and EMI interference.

  • Easy Installation: Base-mounted design minimizes wiring complexity and setup time.

  • Longevity and Support: Backed by Yokogawa’s extended lifecycle management and field service.

  • Field Proven: Trusted by process industries globally for over a decade von reliable performance.


Häufig gestellte Fragen (FAQ)

  1. What is the main function von the SEC402 module?
    It acts as a bus coupler, connecting the FCS to Field I/O modules over the ESB backbone.

  2. Is the SEC402 compatible with both CENTUM VP and CS 3000 systems?
    Yes, it supports both platforms and integrates seamlessly with Yokogawa’s I/O architecture.

  3. Does the module support redundant communication?
    Absolutely. The SEC402 can be used in dual-redundant ESB bus configurations for increased reliability.

  4. How is this module powered?
    It receives 24V DC power from the baseplate it’s mounted on.

  5. What type von I/O modules can it communicate with?
    It interfaces with various Yokogawa FIO modules such as analog input, digital output, etc.

  6. Can it be hot-swapped?
    No, the module should be replaced only during system shutdown or via redundancy failover.

  7. Are there any built-in diagnostics?
    Yes, it includes LED indicators for power, communication activity, and error detection.

  8. Is there any special cabling required for ESB communication?
    Yes, it requires shielded, twisted-pair ESB communication cables as per Yokogawa standards.

  9. What kind von installation environment is required?
    It should be installed inside enclosed control cabinets in industrial environments.

  10. How vonten should the SEC402 be inspected?
    Annual inspections for connection integrity, LED status, and cabinet conditions are recommended.


Related or Same-Series Yokogawa Modells

Modell Beschreibung System Compatibility Gewicht
SEC401 Basic ESB Bus Coupler Module CENTUM VP / CS 3000 0.85 kg
SEC403 Enhanced ESB Coupler with additional diagnostics CENTUM VP 0.92 kg
FIO100 Field I/O Node Controller CENTUM VP / Remote I/O 2.0 kg
SAI143 16-Channel Analog Input Module (4–20mA) FIO System 0.6 kg
SDO143 16-Channel Digital Output Module (Relay) FIO System 0.6 kg
SCP461 Main Processor Module CENTUM VP / CS 3000 1.2 kg

Popular Yokogawa Modells Across the Marke

Modell Beschreibung Application Area Gewicht
CP451 Communication Processor Module for Vnet/IP Network Control 0.9 kg
AAI543 High-Density Analog Input (32ch, 1–5V) Process Signal Acquisition 0.75 kg
PW482 Redundant Power Supply Module FCS / Control Systems 1.6 kg
ALR121 Alarm Relay Output Module Alarm Management 0.7 kg
NTP100 Time Synchronization Module Time-stamping / Networking 0.8 kg
FCS1000 Compact Field Control Station Small-to-medium systems 2.5 kg

Unternehmensinformationen

E-mail: [email protected]

Mobile:Bitte kontaktieren Sie uns per E-Mail

Whatsapp:Bitte kontaktieren Sie uns per E-Mail

Add: Alishan Building, 2 Lvling Rd, Bezirk Siming, Xiamen, Fujian, China, 361006

Unsere Dienstleistungen

Wir sind spezialisiert auf die Lieferung von Industrieautomatisierungsteilen mit einjähriger Garantie. Unsere Industrieautomatisierungsteile werden weltweit verkauft.

Wir können Geräte und Ersatzteile aus verschiedenen Ländern und von verschiedenen Herstellern liefern, Ihre Sorgen oder Qualitätsprobleme an vielen Orten lösen und bieten einen großen Preisvorteil.

Rufen Sie uns gerne an für weitere Produktdetails.

Produktgarantie & Kundensicherheit

Garantiedetails
  • 2 Jahre Standardgarantie – Abdeckung von Material- und Verarbeitungsfehlern
  • Optionale erweiterte Abdeckung – Garantieverlängerung bis zu 5 Jahren
  • Technischer Vor-Ort-Support – Werksgeschulte Ingenieure für den Service verfügbar
  • Austauschprogramm – Priorisierter Austausch innerhalb von 48 Stunden
  • Kontinuierliche technische Unterstützung – Lebenslanger Support für alle Produkte
Qualitätskonformität
  • 100 % getestet und verifiziert – Jede Einheit vor dem Versand geprüft
  • ISO 9001 zertifiziert – Einhaltung des Qualitätsmanagementsystems
  • Umweltkonformität – RoHS- und CE-Normen erfüllt
  • Globale Sicherheitszertifizierungen – UL, cUL und andere anwendbare Zertifizierungen
  • Rückverfolgbare Produktion – Vollständige Serien- und Chargenrückverfolgbarkeit
Rückgabe- und Umtauschrichtlinie
  • 30-tägiges Rückgaberecht – Rückerstattung für ungenutzte Produkte
  • Keine Wiederauffüllungsgebühren – Rücksendungen ohne zusätzliche Gebühren
  • Kostenloser Rückversand – Bei defekten oder falschen Artikeln
  • Cross-Versand-Support – Minimierung der Ausfallzeiten während des Austauschs
  • Einfacher RMA-Prozess – Online-Rückgabeautorisierung verfügbar
Kundenrechte & Support
  • Preisgarantie – 30-tägiger Preisschutz
  • Reservierter Bestand – Bevorzugter Bestand für Stammkunden
  • Technische Schulung – Produktschulungen online und vor Ort verfügbar
  • Integrationshilfe – Technische Unterstützung für SPS/DCS-Integration
  • Support für ältere Produkte – Fortgesetzter Service für ausgelaufene Module
Garantiebedingungen
Abgedeckte Artikel:
  • Herstellungsfehler bei Materialien und Verarbeitung
  • Komponentenausfälle bei normaler Nutzung
  • Firmware- oder Svontwareprobleme (Updates werden bereitgestellt)
  • Fehler oder Auslassungen in der Dokumentation
Ausschlüsse:
  • Falsche Installation oder unsachgemäße Verwendung
  • Nicht autorisierte Änderungen oder Reparaturen
  • Schäden durch Unfälle, Missbrauch oder Vernachlässigung
  • Normale Abnutzung im Laufe der Zeit
Wichtige Hinweise:
  • Alle Garantie- oder Rückgabeanfragen erfordern einen Kaufnachweis
  • Die Originalverpackung sollte für Rücksendungen aufbewahrt werden
  • Kundenspezifisch konfigurierte oder Sonderbestellungen können abweichende Rückgabebedingungen haben
  • Internationale Sendungen können zusätzliche Bearbeitungs- oder Versandanforderungen haben

Technische Dokumentation

Check out Yokogawa SEC402 ESB Bus Coupler Module latest technical documentation.

Kundenbewertungen

Bewertung hinterlassen

Bitte kontaktieren Sie uns per E-Mail [email protected] Bitte kontaktieren Sie uns per E-Mail Follow us on Facebook Subscribe on YouTube