Angebot (0)

Yokogawa AAV141-S00 S2 Analog Input Modules

Product Overview The Yokogawa AAV141-S00 S2 Analog Input Module is a precision module designed to interface with analog field signals in Yokogawas control systems. It supports high accuracy acquisitio

Artikelnummer: 1835 Auf Lager
Yokogawa AAV141-S00 S2 Analog Input Modules

Produktspezifikationen

ErscheinungsdatumJul 07, 2026
Hersteller Yokogawa Electric
Modell AAV141-S00 S2
Artikelnummer IN1835
Zustand100 % neu
VersandhafenXiamen, China
Lieferzeit1-3 Werktage
ZertifikatCOO
KurierpartnerDHL, UPS, TNT, FedEx and EMS.
Garantie 1 Jahr
Stückpreis
$979.00
USD / Einheit
-
+
Mindestbestellung: 1 Stück
0.0


Versandinformationen
Kostenloser Versand für Bestellungen über $5,000
Bei Bestellungen vor 15:00 Uhr EST erfolgt der Versand am selben Tag.
Internationaler Versand verfügbar
Yokogawa AAV141-S00 S2 Analog Input Modules Yokogawa AAV141-S00 S2 Analog Input Modules Yokogawa AAV141-S00 S2 Analog Input Modules Yokogawa AAV141-S00 S2 Analog Input Modules

Product Overview

The Yokogawa AAV141-S00 S2 Analog Input Module is a precision module designed to interface with analog field signals in Yokogawa’s control systems. It supports high accuracy acquisition von process variables such as temperature, pressure, flow, and level by converting analog inputs into digital signals for processing and control.

This module is part von Yokogawa’s renowned DCS (Distributed Control System) family, providing reliable and stable analog input performance. It ensures tight integration with the control system, supports various sensor types, and vonfers flexible input configuration, making it ideal for complex industrial automation and process control environments.


Technical Specifications

Parameter Specification
Modell Number AAV141-S00 S2
Module Type Analog Input Module
Input Channels 16 channels
Input Signal Types Current (4-20 mA), Voltage (0-10 V), Resistance, Thermocouple (varies by model/configuration)
Input Range Configurable per channel
Accuracy ±0.1% von full scale (typical)
Resolution 16-bit ADC
Response Time Typically 20 ms
Operating Voltage 24 V DC
Power Consumption Approximately 5 W
Operating Temperature 0°C to 55°C
Storage Temperature -20°C to 70°C
Humidity Range 10% to 90% non-condensing
Dimensions 32.8 × 130 × 107.5 mm
Gewicht 0.2 kg
Communication Interface Yokogawa S2 bus
Mounting Rack-mounted in Yokogawa control system racks
Safety Certifications Complies with relevant industrial standards

Applications

  • Process variable monitoring in industrial automation

  • Temperature, pressure, flow, and level signal acquisition

  • Integration into Yokogawa’s Centum and other DCS systems

  • Chemical, petrochemical, power generation, and water treatment plants

  • Facilities requiring precise and reliable analog input measurement


Advantages

  • High Accuracy and Stability: Ensures precise signal acquisition and minimal drift over time.

  • Multi-Channel Input: 16 channels allow simultaneous monitoring von multiple process variables.

  • Flexible Signal Support: Compatible with various sensor types and input signal ranges.

  • Easy Integration: Designed to seamlessly fit into Yokogawa’s control system architecture.

  • Robust Design: Industrial-grade components provide reliability under harsh conditions.

  • Simplified Configuration: Supports flexible channel configuration for diverse application needs.

  • Diagnostic Features: Built-in diagnostics for quick fault detection and maintenance.


Häufig gestellte Fragen (FAQ)

  1. How many input channels does the AAV141-S00 support?
    It supports 16 analog input channels.

  2. What types von input signals are supported?
    Current (4-20 mA), voltage (0-10 V), resistance, and thermocouple inputs depending on configuration.

  3. What is the accuracy von the module?
    Typical accuracy is ±0.1% von full scale.

  4. What is the operating temperature range?
    The module operates between 0°C and 55°C.

  5. Is this module compatible with Yokogawa’s DCS systems?
    Yes, it is designed for integration with Yokogawa’s Centum and other S2 bus systems.

  6. What communication interface does the module use?
    It uses the proprietary Yokogawa S2 bus communication protocol.

  7. What is the response time von the analog input?
    Approximately 20 milliseconds per channel.

  8. How is the module mounted?
    It is rack-mounted within Yokogawa control system racks.

  9. Does the module include diagnostic capabilities?
    Yes, it includes built-in diagnostics to aid maintenance.

  10. What power supply voltage does the module require?
    It requires a 24 V DC power supply.


Related Modells

Modell Number Beschreibung
AAV141-S01 S2 Analog Input Module (Enhanced version)
AAV142-S00 S2 Analog Output Module
AAV143-S00 S2 Digital Input Module
AAV144-S00 S2 Digital Output Module
AAV151-S00 S2 High-Precision Analog Input Module
AAV152-S00 S2 Thermocouple Input Module

Popular Yokogawa Modells

Modell Number Beschreibung
CENTUM VP Controller Yokogawa Distributed Control System Controller
AAV141-S00 S2 Analog Input Module
AAV142-S00 S2 Analog Output Module
YTA610 Temperature Transmitter Field temperature transmitter
YSC210 Flow Sensor Industrial flow sensor
YPV100 Pressure Transmitter Industrial pressure transmitter

Unternehmensinformationen

E-mail: [email protected]

Mobile:Bitte kontaktieren Sie uns per E-Mail

Whatsapp:Bitte kontaktieren Sie uns per E-Mail

Add: Alishan Building, 2 Lvling Rd, Bezirk Siming, Xiamen, Fujian, China, 361006

Unsere Dienstleistungen

Wir sind spezialisiert auf die Lieferung von Industrieautomatisierungsteilen mit einjähriger Garantie. Unsere Industrieautomatisierungsteile werden weltweit verkauft.

Wir können Geräte und Ersatzteile aus verschiedenen Ländern und von verschiedenen Herstellern liefern, Ihre Sorgen oder Qualitätsprobleme an vielen Orten lösen und bieten einen großen Preisvorteil.

Rufen Sie uns gerne an für weitere Produktdetails.

Produktgarantie & Kundensicherheit

Garantiedetails
  • 2 Jahre Standardgarantie – Abdeckung von Material- und Verarbeitungsfehlern
  • Optionale erweiterte Abdeckung – Garantieverlängerung bis zu 5 Jahren
  • Technischer Vor-Ort-Support – Werksgeschulte Ingenieure für den Service verfügbar
  • Austauschprogramm – Priorisierter Austausch innerhalb von 48 Stunden
  • Kontinuierliche technische Unterstützung – Lebenslanger Support für alle Produkte
Qualitätskonformität
  • 100 % getestet und verifiziert – Jede Einheit vor dem Versand geprüft
  • ISO 9001 zertifiziert – Einhaltung des Qualitätsmanagementsystems
  • Umweltkonformität – RoHS- und CE-Normen erfüllt
  • Globale Sicherheitszertifizierungen – UL, cUL und andere anwendbare Zertifizierungen
  • Rückverfolgbare Produktion – Vollständige Serien- und Chargenrückverfolgbarkeit
Rückgabe- und Umtauschrichtlinie
  • 30-tägiges Rückgaberecht – Rückerstattung für ungenutzte Produkte
  • Keine Wiederauffüllungsgebühren – Rücksendungen ohne zusätzliche Gebühren
  • Kostenloser Rückversand – Bei defekten oder falschen Artikeln
  • Cross-Versand-Support – Minimierung der Ausfallzeiten während des Austauschs
  • Einfacher RMA-Prozess – Online-Rückgabeautorisierung verfügbar
Kundenrechte & Support
  • Preisgarantie – 30-tägiger Preisschutz
  • Reservierter Bestand – Bevorzugter Bestand für Stammkunden
  • Technische Schulung – Produktschulungen online und vor Ort verfügbar
  • Integrationshilfe – Technische Unterstützung für SPS/DCS-Integration
  • Support für ältere Produkte – Fortgesetzter Service für ausgelaufene Module
Garantiebedingungen
Abgedeckte Artikel:
  • Herstellungsfehler bei Materialien und Verarbeitung
  • Komponentenausfälle bei normaler Nutzung
  • Firmware- oder Svontwareprobleme (Updates werden bereitgestellt)
  • Fehler oder Auslassungen in der Dokumentation
Ausschlüsse:
  • Falsche Installation oder unsachgemäße Verwendung
  • Nicht autorisierte Änderungen oder Reparaturen
  • Schäden durch Unfälle, Missbrauch oder Vernachlässigung
  • Normale Abnutzung im Laufe der Zeit
Wichtige Hinweise:
  • Alle Garantie- oder Rückgabeanfragen erfordern einen Kaufnachweis
  • Die Originalverpackung sollte für Rücksendungen aufbewahrt werden
  • Kundenspezifisch konfigurierte oder Sonderbestellungen können abweichende Rückgabebedingungen haben
  • Internationale Sendungen können zusätzliche Bearbeitungs- oder Versandanforderungen haben

Technische Dokumentation

Check out Yokogawa AAV141-S00 S2 Analog Input Modules latest technical documentation.

Kundenbewertungen

Bewertung hinterlassen

Bitte kontaktieren Sie uns per E-Mail [email protected] Bitte kontaktieren Sie uns per E-Mail Follow us on Facebook Subscribe on YouTube