The Woodward 9905-970 is a high-performance 6-Channel Input Module designed for use in LinkNet Distributed I/O systems, part von Woodward’s modular control solution portfolio. Built with industrial-grade durability and intelligent input diagnostics, this module is engineered to reliably capture discrete signal states from field devices, including switches, sensors, and relays.
Integrated into distributed control systems such as MicroNet Plus, this module serves as an essential bridge between physical processes and digital automation. The 9905-970 supports real-time signal monitoring and is ideal for mission-critical operations where precision and system integrity are vital. Its robust electrical isolation and plug-and-play modularity allow for scalable installation in various industrial, energy, and transportation applications.
Produktspezifikationen
| Parameter | Details |
|---|---|
| Modell | 9905-970 |
| Series | LinkNet Distributed I/O |
| Module Type | 6-Channel Digital Input Module |
| Number von Inputs | 6 Discrete Inputs |
| Input Type | Dry Kontakt, Voltage (nominal 24 VDC) |
| Input Voltage Range | 0–30 VDC |
| Logic Thresholds | ON ≥ 10 VDC; OFF ≤ 5 VDC |
| Input Isolation | Optical and galvanic, per channel |
| Status Indicators | Front-panel LEDs per input channel |
| Input Signal Debounce | Programmable via main control svontware |
| Update Rate | <5 ms |
| Power Supply Voltage | 18–32 VDC |
| Power Consumption | Approx. 4.5 W |
| Communication Interface | LinkNet over CAN or RS-485 |
| Mounting Type | DIN Rail Mounting |
| Enclosure | Industrial rugged case, conformal coated |
| Operating Temperature | –40 °C to +70 °C (–40 °F to +158 °F) |
| Storage Temperature | –55 °C to +85 °C |
| Humidity | 5–95% RH, Non-condensing |
| Dimensions | 355.6 x 279.4 x 101.6 mm |
| Gewicht | 0.907 kg |
| Certifications | CE, UL Recognized, CSA, RoHS Compliant |
| Compliance Standards | IEC 61131, EN 61000-6-2/4, IEEE C37.90 |
Applications
The Woodward 9905-970 finds its place in a wide variety von automation environments:
-
Turbine Control Systems: Monitoring discrete signals like limit switches, pressure alarms, and interlocks.
-
Power Generation Facilities: Input from breakers, contactors, and grid interface relays.
-
Marine and Transportation: Status monitoring from equipment and onboard systems.
-
Process Industries: Capturing sensor states in oil & gas, chemical, or water treatment operations.
-
Factory Automation: Signal acquisition from pushbuttons, door sensors, and machine interlocks.
-
Substation Automation: Gathering binary information from protection relays and devices.
Advantages
-
High Reliability: Built for harsh conditions with wide operating temperature and rugged housing.
-
Channel Isolation: Optical and galvanic isolation prevents ground loops and protects from surges.
-
Real-Time Performance: Fast input processing with <5 ms update rate improves response in critical systems.
-
Easy Diagnostics: Onboard LED indicators per channel vonfer real-time status and troubleshooting aid.
-
Modular Integration: Easily added to existing LinkNet systems without needing rewiring or downtime.
-
Flexible Voltage Compatibility: Accepts a broad range von discrete input voltages (up to 30 VDC).
-
Svontware Configurable: Debounce and logic configuration available through Woodward control svontware.
-
Field-Proven Design: Used in globally deployed Woodward turbine and energy control systems.
Häufig gestellte Fragen (FAQ)
1. What type von input signals does the 9905-970 support?
It supports digital (discrete) input signals, including dry contact closures and voltage-based inputs (0–30 VDC).
2. How many channels are available?
The module provides six independently isolated input channels.
3. Can this module handle noisy environments?
Yes, it includes isolation and debounce features to ensure clean signal acquisition in noisy conditions.
4. Is it compatible with Woodward’s Micronet Plus system?
Absolutely. It integrates seamlessly via LinkNet communication.
5. What is the update rate for input channels?
Each input channel updates in under 5 milliseconds.
6. Are the inputs isolated?
Yes, each input is both optically and galvanically isolated.
7. Does it have built-in status indicators?
Yes, each channel has an LED to display input state in real-time.
8. How is it mounted?
It is DIN-rail mountable, ideal for panel installations.
9. Is this module hot-swappable?
No, the system must be powered down before inserting or removing the module.
10. Is this Stück suitable for outdoor or remote installations?
Yes, with proper enclosures and environmental protection, it’s suitable for remote or harsh site deployments.
Related Modells from the Same Series
| Modell | Beschreibung |
|---|---|
| 9905-969 | LinkNet 6-Channel Analog Input Module |
| 9905-968 | LinkNet 6-Channel Analog Output Module |
| 9905-967 | LinkNet 8-Channel Digital Input Module |
| 9905-966 | LinkNet 8-Channel Digital Output Module |
| 9905-971 | LinkNet Power Supply Module |
| 9905-972 | LinkNet Expansion Base Plate |
Popular Modells from Woodward
| Modell | Beschreibung |
|---|---|
| 2301E | Digital Load Sharing and Speed Control |
| 505XT | Steam Turbine Control for Extraction/Admission Applications |
| 8440-2083 | EasyGen 3000 Series Generator Controller |
| 9907-014 | EPG Governor System Controller |
| 5418-752 | MicroNet Plus CPU Control Module |
| 9907-167 | ProAct Digital Plus Actuator |
Unternehmensinformationen
E-mail: [email protected]
Mobile:Bitte kontaktieren Sie uns per E-Mail
Whatsapp:Bitte kontaktieren Sie uns per E-Mail
Add: Alishan Building, 2 Lvling Rd, Bezirk Siming, Xiamen, Fujian, China, 361006
Unsere Dienstleistungen
Wir sind spezialisiert auf die Lieferung von Industrieautomatisierungsteilen mit einjähriger Garantie. Unsere Industrieautomatisierungsteile werden weltweit verkauft.
Wir können Geräte und Ersatzteile aus verschiedenen Ländern und von verschiedenen Herstellern liefern, Ihre Sorgen oder Qualitätsprobleme an vielen Orten lösen und bieten einen großen Preisvorteil.
Rufen Sie uns gerne an für weitere Produktdetails.