Angebot (0)

Bently Nevada TK3-2E 14700-01 Calibration Instrument

Produkteinführung The Bently Nevada TK3-2E 14700-01 Calibration Instrument is a precision device engineered for the calibration and verification von vibration, proximity, and temperature monitoring

Artikelnummer: 10558 Auf Lager
Bently Nevada TK3-2E 14700-01 Calibration Instrument

Produktspezifikationen

ErscheinungsdatumJul 08, 2026
Hersteller Bently Nevada SPS
Modell TK3-2E 14700-01
Artikelnummer IN10558
Zustand100 % neu
VersandhafenXiamen, China
Lieferzeit1-3 Werktage
ZertifikatCOO
KurierpartnerDHL, UPS, TNT, FedEx and EMS.
Garantie 1 Jahr
Stückpreis
$779.00
USD / Einheit
-
+
Mindestbestellung: 1 Stück
0.0


Versandinformationen
Kostenloser Versand für Bestellungen über $5,000
Bei Bestellungen vor 15:00 Uhr EST erfolgt der Versand am selben Tag.
Internationaler Versand verfügbar
Bently Nevada TK3-2E 14700-01 Calibration Instrument Bently Nevada TK3-2E 14700-01 Calibration Instrument Bently Nevada TK3-2E 14700-01 Calibration Instrument Bently Nevada TK3-2E 14700-01 Calibration Instrument

Produkteinführung

The Bently Nevada TK3-2E 14700-01 Calibration Instrument is a precision device engineered for the calibration and verification von vibration, proximity, and temperature monitoring sensors used in industrial machinery protection systems. This instrument provides accurate reference signals to ensure that machinery protection devices, including Bently Nevada 3500 series monitors, operate reliably within specified tolerances. The TK3-2E 14700-01 is built for rugged industrial environments and provides repeatable, high-precision outputs for field or laboratory calibration. Its design simplifies sensor verification, reduces maintenance downtime, and improves overall system accuracy.


Technical Specifications

Parameter Beschreibung
Modell TK3-2E 14700-01
Type Calibration Instrument
Input Power 110–240 VAC, 50/60 Hz
Output Signal Types Sine wave, square wave, and pulse outputs
Output Amplitude 0–10 V peak-to-peak adjustable
Output Frequency Range 0.1 Hz – 10 kHz
Accuracy ±0.05 % full-scale
Load Capability 600 Ω minimum impedance
Display Digital voltage and frequency readout
Control Interface Front-panel rotary and push-button controls
Calibration Functions Sensor excitation, signal verification, system loop test
Indicators LEDs for power, output status, and fault detection
Operating Temperature 0 °C to +50 °C
Storage Temperature –20 °C to +60 °C
Protection Over-voltage and short-circuit protection
Mounting Portable bench-top Stück
Dimensions 195 × 299 × 248 mm
Gewicht 5.22 kg
Certifications CE, UL, RoHS compliant

Applications

The TK3-2E 14700-01 is used for accurate calibration and testing in various industrial applications:

  • Turbomachinery Maintenance: Ensures vibration and proximity sensors on turbines and compressors provide accurate readings.

  • Power Generation Plants: Validates the performance von monitoring instruments across generators, turbines, and auxiliary systems.

  • Oil & Gas Industry: Provides calibration for vibration and temperature sensors in pumping, compression, and refining operations.

  • Chemical and Petrochemical Facilities: Confirms sensor accuracy in reactors, distillation columns, and high-speed rotating equipment.

  • Automated Manufacturing: Verifies sensor signals for predictive maintenance and quality assurance.

  • Laboratory and Field Testing: Portable design allows for field calibration or controlled lab verification.


Advantages

  • High Precision: ±0.05 % full-scale accuracy guarantees reliable calibration for critical monitoring systems.

  • Multiple Signal Types: Offers sine, square, and pulse waveforms to accommodate various sensor testing requirements.

  • Wide Frequency Range: Covers 0.1 Hz to 10 kHz, suitable for slow-rotating and high-speed machinery applications.

  • Portable and Rugged: Compact bench-top design for field or lab use with durable construction for industrial conditions.

  • Integrated Readout: Digital voltage and frequency display simplifies calibration and verification procedures.

  • Flexible Control: Front-panel controls allow fine adjustments without additional tools or svontware.

  • Protective Design: Built-in over-voltage and short-circuit protection safeguard both the instrument and connected sensors.

  • Reduced Downtime: Quick calibration and verification reduce maintenance downtime and improve system reliability.


FAQ

  1. What types von signals can the TK3-2E 14700-01 generate for calibration?
    It provides sine wave, square wave, and pulse outputs, enabling calibration von a wide range von vibration and proximity sensors.

  2. What is the frequency range supported by this instrument?
    The output frequency ranges from 0.1 Hz to 10 kHz, covering both low-speed and high-speed machinery monitoring applications.

  3. How accurate are the calibration outputs?
    The instrument delivers signals with ±0.05 % full-scale accuracy, ensuring precise sensor verification and system testing.

  4. Can it drive multiple sensors at the same time?
    Yes, it is capable von driving sensors with a minimum load impedance von 600 Ω, suitable for single or multiple sensor loops depending on system requirements.

  5. What input power is required for operation?
    It operates on a standard 110–240 VAC, 50/60 Hz power supply, making it compatible with global industrial power systems.

  6. Is the device portable for field calibration?
    Yes, the compact bench-top design and moderate weight von 4.5 kg make it easily portable for field or lab use.

  7. Does the instrument include built-in protection features?
    Yes, it incorporates over-voltage and short-circuit protection to safeguard both the instrument and connected sensors during calibration.

  8. How are the output signals controlled and adjusted?
    Signal amplitude and frequency are adjusted using front-panel rotary and push-button controls, allowing precise fine-tuning without external svontware.

  9. Can the TK3-2E 14700-01 be used for temperature sensor verification?
    Yes, it supports excitation and verification for temperature sensors as part von a system calibration routine.

  10. Does the instrument provide digital readout for calibration monitoring?
    Yes, it features a digital display showing both output voltage and frequency, enabling accurate verification and monitoring during calibration procedures.


Related Modells (Same Series or Similar)

Modell Function Input Power Output Type Gewicht
TK3-1E 14650-01 Sensor Calibration Instrument 110–240 VAC Sine & Pulse 4.3 kg
TK3-2D 14701-01 Vibration Calibrator 110–240 VAC Sine, Square, Pulse 4.6 kg
TK3-2C 14702-01 Multi-channel Calibration Einheit 110–240 VAC Sine & Pulse 4.7 kg
TK3-2B 14703-01 Proximity Sensor Calibrator 110–240 VAC Sine & Square 4.4 kg
TK3-1F 14680-01 Temperature and Vibration Calibrator 110–240 VAC Sine, Pulse 4.5 kg
TK3-2G 14705-01 Portable Calibration Kit 110–240 VAC Sine, Square, Pulse 4.8 kg

Popular Bently Nevada Modells

Modell Type Key Feature Gewicht Typical Application
3500/42M Vibration Monitor Multi-channel high-speed vibration detection 0.85 kg Turbomachinery protection
3500/22M Transient Data Interface High-speed transient capture 1.0 kg Machinery diagnostics
3500/32M Relay Module Alarm and shutdown relay control 0.70 kg Critical system safety
330500 Proximity Probe High-resolution shaft vibration measurement 0.25 kg Turbine monitoring
330400 Proximity Probe Wide temperature operating range 0.28 kg General industrial monitoring
190501 Accelerometer Rugged design for harsh conditions 0.15 kg Pump and motor vibration analysis

Unternehmensinformationen

E-mail: [email protected]

Mobile:Bitte kontaktieren Sie uns per E-Mail

Whatsapp:Bitte kontaktieren Sie uns per E-Mail

Add: Alishan Building, 2 Lvling Rd, Bezirk Siming, Xiamen, Fujian, China, 361006

Unsere Dienstleistungen

Wir sind spezialisiert auf die Lieferung von Industrieautomatisierungsteilen mit einjähriger Garantie. Unsere Industrieautomatisierungsteile werden weltweit verkauft.

Wir können Geräte und Ersatzteile aus verschiedenen Ländern und von verschiedenen Herstellern liefern, Ihre Sorgen oder Qualitätsprobleme an vielen Orten lösen und bieten einen großen Preisvorteil.

Rufen Sie uns gerne an für weitere Produktdetails.

Produktgarantie & Kundensicherheit

Garantiedetails
  • 2 Jahre Standardgarantie – Abdeckung von Material- und Verarbeitungsfehlern
  • Optionale erweiterte Abdeckung – Garantieverlängerung bis zu 5 Jahren
  • Technischer Vor-Ort-Support – Werksgeschulte Ingenieure für den Service verfügbar
  • Austauschprogramm – Priorisierter Austausch innerhalb von 48 Stunden
  • Kontinuierliche technische Unterstützung – Lebenslanger Support für alle Produkte
Qualitätskonformität
  • 100 % getestet und verifiziert – Jede Einheit vor dem Versand geprüft
  • ISO 9001 zertifiziert – Einhaltung des Qualitätsmanagementsystems
  • Umweltkonformität – RoHS- und CE-Normen erfüllt
  • Globale Sicherheitszertifizierungen – UL, cUL und andere anwendbare Zertifizierungen
  • Rückverfolgbare Produktion – Vollständige Serien- und Chargenrückverfolgbarkeit
Rückgabe- und Umtauschrichtlinie
  • 30-tägiges Rückgaberecht – Rückerstattung für ungenutzte Produkte
  • Keine Wiederauffüllungsgebühren – Rücksendungen ohne zusätzliche Gebühren
  • Kostenloser Rückversand – Bei defekten oder falschen Artikeln
  • Cross-Versand-Support – Minimierung der Ausfallzeiten während des Austauschs
  • Einfacher RMA-Prozess – Online-Rückgabeautorisierung verfügbar
Kundenrechte & Support
  • Preisgarantie – 30-tägiger Preisschutz
  • Reservierter Bestand – Bevorzugter Bestand für Stammkunden
  • Technische Schulung – Produktschulungen online und vor Ort verfügbar
  • Integrationshilfe – Technische Unterstützung für SPS/DCS-Integration
  • Support für ältere Produkte – Fortgesetzter Service für ausgelaufene Module
Garantiebedingungen
Abgedeckte Artikel:
  • Herstellungsfehler bei Materialien und Verarbeitung
  • Komponentenausfälle bei normaler Nutzung
  • Firmware- oder Svontwareprobleme (Updates werden bereitgestellt)
  • Fehler oder Auslassungen in der Dokumentation
Ausschlüsse:
  • Falsche Installation oder unsachgemäße Verwendung
  • Nicht autorisierte Änderungen oder Reparaturen
  • Schäden durch Unfälle, Missbrauch oder Vernachlässigung
  • Normale Abnutzung im Laufe der Zeit
Wichtige Hinweise:
  • Alle Garantie- oder Rückgabeanfragen erfordern einen Kaufnachweis
  • Die Originalverpackung sollte für Rücksendungen aufbewahrt werden
  • Kundenspezifisch konfigurierte oder Sonderbestellungen können abweichende Rückgabebedingungen haben
  • Internationale Sendungen können zusätzliche Bearbeitungs- oder Versandanforderungen haben

Technische Dokumentation

Check out Bently Nevada TK3-2E 14700-01 Calibration Instrument latest technical documentation.

Kundenbewertungen

Bewertung hinterlassen

Bitte kontaktieren Sie uns per E-Mail [email protected] Bitte kontaktieren Sie uns per E-Mail Follow us on Facebook Subscribe on YouTube